TROUBLESHOOTING

Troubleshooting the M-64
Problem
The receiver has no lights on.
The LCD Display shows error E1, E2,
E3, E4, E5, E6.
The LCD Display shows error E7.
The LCD Display shows error E8.
System Installation Troubleshooting
Problem
The keypad is connected, but
no lights come on.
There is no IR control of the source
components.
Some IR commands work for a source
and some don't.
Troubleshooting
Inspect the AC power cord. Be sure it is inserted firmly into the power-cord socket of the receiver.
Check the AC power outlet. Verify that the outlet is providing power (i.e., a switched AC outlet).
Ensure that the M-64 is always plugged into an unswitched AC outlet. If you've checked the cord and
the outlet, and you still have no lights, call JobSite for service.
Errors E1 through E6 mean that an internal problem exists and the M-64 requires service
Error E7 means one or more of the front-panel control or programming buttons is stuck in the
depressed position.
Check each of the buttons by pressing and releasing them.
One or more of the M-64's in an expanded system are not set to the proper Master/Slave mode.
Refer to the Installation Settings of this manual for proper setup.
Troubleshooting
Test the keypad cable with an appropriate cable tester.
There is no IR control of the source components.
The Receivers may be receiving some interference. Check the status LED.
When using the JobSite IR Receivers, the Status LED should be illuminating green when the zone
is on.
The Status LED should be off when the zone is off, and it should be red when it is receiving an
IR command.
You may have captured some IR commands incorrectly. Testing all IR commands as you capture
them with the IR test feature will avoid this.