NGI N36600 Series User Manual

Portable wide range programmable dc power supply

Advertisement

ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING
User Manual
N36600 Series Portable Wide Range
Programmable DC Power Supply
Hunan Next Generation Instrumental T&C Tech. Co., Ltd.
Version: V20231130

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the N36600 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NGI N36600 Series

  • Page 1 ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING User Manual N36600 Series Portable Wide Range Programmable DC Power Supply Hunan Next Generation Instrumental T&C Tech. Co., Ltd. Version: V20231130...
  • Page 2: Copyright Statement

    (including electronic storage and retrieval or translation into a foreign language). NGI shall not be liable for errors or for incidental or consequential damages in connection with the provision, use or application of this manual and any information contained herein.
  • Page 3: Table Of Contents

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING Contents 1 PREFACE ........................4 2 SAFETY INSTRUCTIONS ....................5 2.1 Safety Symbols ....................5 2.2 Safety Notes .....................5 3 INSPECTION AND INSTALLATION ................6 3.1 Inspection ......................6 3.2 Connection to Power Cord ................6 3.3 Power-on Inspection ..................7 3.4 Load Connection ....................
  • Page 4 ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 5.11 GRP .......................26 5.12 BAUD ......................27 5.13 PROT ......................27 5.14 VPLC ......................28 5.15 APLC ......................28 5.16 TRIG ......................29 5.17 TYPE ......................29 5.18 COUN ......................30 5.19 Set Shortcuts ....................31 5.20 Use shortcut feature ..................32 5.21 CV&CC Mode ....................32 6 MAINTENANCE AND SELF-INSPECTION ..............
  • Page 5: Preface

    1 Preface Dear Customers First of all, we greatly appreciate your choice of N36600 series DC Power Supply (N36600 for short). We are also honored to introduce our company, Hunan Next Generation Instrumental T&C Tech. Co., Ltd.( NGI for short).
  • Page 6: Safety Instructions

    NGI shall not be liable for the results caused by the neglect of those instructions. 2.1 Safety Symbols Please refer to the following table for definitions of international symbols used on the instrument or in the user manual.
  • Page 7: Inspection And Installation

    Note 1: If any severe damage to the package, please contact our authorized distributor or NGI. Send it back after getting a positive response. 2: If no problem, please keep it carefully. Compliance with packing requirements when returning for service.
  • Page 8: Power-On Inspection

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 3.3 Power-on Inspection After receiving N36600 device, please check the device by following these steps:  Switch-On Press the POWER button on the front panel to turn on the device. If you find that the power supply cannot start normally, first check whether the power cable is connected, whether the power supply has been powered, and whether the power switch has been turned on.
  • Page 9: Load Connection

    3.4 Load Connection 3.4.1 Load Wires N36600 series power supply does not provide load wires, users need to choose their own wires. The following points should be noted when selecting the wires between the load and the power supply: ...
  • Page 10 ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING supply can use the remote sampling function to compensate the voltage, but it is recommended to minimize the voltage drop). 3.4.1.2 Effects of Noise and Impedance In order to reduce noise or radiation, the load wires and the remote sense wires should be twisted pair and the length should be as short as possible.
  • Page 11 ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING When supplying power to inductive loads such as motors, load transients, such as counter electromotive force from motors, may occur. Please connect a surge current suppressor across the output to protect the power supply. The rated breakdown voltage of surge current suppressor must be approximately 10% higher than the rated output voltage of the power supply.
  • Page 12: Product

    4 Product 4.1 Brief Introduction N36600 series programmable DC power supply has the widest voltage and current utilization rate of similar products, greatly improving the application range. For example, 100W power, the output value is adjustable in 80V/5A, and the rate of change of voltage and current is automatically controlled, and the power ratio reaches four times as much.
  • Page 13: Appearance & Dimension

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 4.2 Appearance & Dimension N36600 series product dimension: Figure1 Front Panel Dimension (mm) Figure2 Side View Size (mm)
  • Page 14 ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING Figure3 Rear Panel Dimension(mm)
  • Page 15: Front Panel Introduction

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 4.3 Front Panel Introduction Figure4 Front Panel Introduction Table2 Serial No. Name Description ① Screen Displaying information ② Function buttons&knobs Device operation ③ switch turn on/off ④ Output terminal Dc power output terminal 4.3.1 Button & Knob Figure5 button&knob...
  • Page 16: Rear Panel Introduction

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING Table3 Button/Knob Name and Function Navigate key (Left)+Shortcut A, Shortcut Save (Shift) Navigate key (Right)+Shortcut B, Shortcut Prog (Shift) Enter+Shortcut C, Shortcut Lock (Shift) Voltage/Current Setting +Shortcut D, Power setup (Shift) Second function switch, Check set value (Shift) Output On/Off Adjust numeric values 4.4 Rear Panel Introduction...
  • Page 17: Ac Input Port

    Ground terminal Chassis ground terminal 4.4.1 Ac Input Port Please pay attention to the following for N36600 series power input connection:  AC input:Single phase, please refer to the voltage mark at the rear panel.  Ensure reliable grounding; 4.4.2 LAN Port LAN port is a default communication port for N36600.
  • Page 18: Rs232 Interface

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 4.4.3 RS232 Interface On the rear panel, there is a male DB-9 interface with 9 pins. Table5 Definition ① ② RXD, receive data TXD, transmit ③ data ④ ⑤ GND, ground ⑥ Figure7 RS232 Interface ⑦...
  • Page 19: Four-Wire Interface

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 4.4.5 Four-wire Interface Figure9 4-wire interface Four-wire interface providing local and remote sense. Table7 Definition Remote sense positive polarity Local sense positive polarity,internally connected to positive output terminal Local sense negative polarity,internally connected to negative output terminal Remote sense negative polarity 4.4.6 Grounding Screw...
  • Page 20: Start

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 5. Start 5.1 Interface Introduction Display screen is used in N36600 series. Figure10 Display screen Table8 Characters Function Description Power output off The power supply is in constant voltage output state The power supply is in constant current output state...
  • Page 21: Set Voltage

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 5.2 Set Voltage Press to move the cursor to V, and V blinks. At this time, the power supply is in voltage setting mode. Press to adjust the step to position B. At this time, the voltage will rise or fall by 1V for each rotation of the knob.
  • Page 22: Turn On Power Output

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 5.4 Turn on Power Output After the power output is turned on by pressing , the display on the screen will change from the set value to the actual measured voltage and current value of the power output.
  • Page 23: Display Time And Power

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 5.5 Display Time and Power After pressing the , the Shift indicator is on, and then pressing the knob, the voltage/current display will switch to the time/power display. The S position shows the time the output is turned on in seconds, and the W position shows the output power in watts.
  • Page 24: Protection

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING At this time, all the keys and knobs on the keyboard are locked except the . Repeat the above steps to unlock the keypad. 5.8 Protection 5.8.1 Overvoltage Protection (OVP) Press the , then press the (Setup) for about 5 seconds, and INIT will be displayed on the screen.
  • Page 25: Overcurrent Protection (Ocp)

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 5.8.2 Overcurrent Protection (OCP) After setting OVP, press button to enter the OCP setting interface. You can to adjust the OCP current. Figure16 Overcurrent protection settings Note OVP and OCP values set below the actual use of voltage/current value will cause power protection, output shut off, the factory preset value is the nominal maximum value.
  • Page 26: P_On

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 5.8.3 P_ON After setting OVP/OCP, press to enter the P_ON setting interface. You can use the knob to select ON/OFF. ON means to turn on the OVP/OCP protection function, and OFF means to turn it off. Press to confirm.
  • Page 27: Add

    Figure 19 5.11 GRP After setting ADD, press to enter the GRP setting interface. You can use to make shortcut group selection. Press to confirm. N36600 series allows customers to set up 100 sets of shortcuts. Figure 20...
  • Page 28: Baud

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 5.12 BAUD After setting GRP, press button to enter the BAUD setting interface. You can use the knob to select the baud rate, which respectively is 9600→19200→38400→57600→115200, and press button to confirm. The baud rate require a restart to become effective. Figure 21 5.13 PROT After setting BAUD, press...
  • Page 29: Vplc

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 5.14 VPLC After setting PROT, press to enter the VPLC setting interface, you can use the knob to select ON/OFF. ON enables the voltage sampling filter function, and OFF disables this function. Press to confirm. Figure 23 5.15 APLC After setting the VPLC, press...
  • Page 30: Trig

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 5.16 TRIG After setting APLC, press button to enter the TRIG setting interface. You can use the knob to select the code, and press to confirm. Code description: 0 Triggered by an external key 1 Rear panel TTL trigger 2 Communication interface is triggered 3 "TRIGger:IMMediate"...
  • Page 31: Coun

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING Figure 26 5.18 COUN After setting TYPE, press button to enter the COUN setting interface. You can use the knob to select the or the average number. The attenuation constant default is 10. Press button to confirm and end Setup mode.
  • Page 32: Set Shortcuts

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING With the specified attenuation constant, the numerical data were averaged exponentially according to the following formula. Dn: Value displayed after the NTH exponential averaging (D1=M1) Dn1: The value displayed after the (N-1)TH exponential averaging Mn: The numerical data for the NTH time K: attenuation constant Moving Average (Lin)
  • Page 33: Use Shortcut Feature

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING any shortcut key to save the set value in this shortcut key for direct call in the future. 5.20 Use shortcut feature After pressing , press (Prog), then the Prog indicator displays, indicating that the current work is in the shortcut key mode. You can press any key to call the prestored voltage and current value in the key.
  • Page 34: Maintenance And Self-Inspection

    Due to system upgrade or hardware problem, the device may break down. Please do the following necessary inspection to eliminate the troubles, which can save your maintenance and time cost. If the troubles cannot be recovered, please contact NGI. The inspection steps are as below.
  • Page 35: Main Technical Data

    ELECTRONIC SOLUTION PROVIDER FOR INTELLIGENT MANUFACTURING 7 Main Technical Data Table10 Model N36610-80-06 N36620-80-08 Voltage 0.5~81V 0.5~81V Current 0~6.0A 0~8.2A Power 100W 200W CV Mode Range 0.5~81V Setting resolution 10mV Setting accuracy 0.05%+10mV (23±5℃) CC Mode Range 0~6.0A 0~8.2A Setting resolution Setting accuracy (23±5℃) 0.2%+2mA 0.2%+5mA...
  • Page 36 AC input rear panel. Operating environment 0℃~40℃,≤80% (non-condensing) Storage temperature -10℃~70℃,≤70% (non-condensing) Interface RS232、RS485、LAN Dimension 55 mm(W)*315 mm(D)*140 mm(H) Net weight 1.8kg Note 1: For other specifications, please contact NGI. Note 2: All specifications are subject to change without notice.

This manual is also suitable for:

N36610-80-06N36620-80-08

Table of Contents