Majestic BE42 Installation Manual

Majestic BE42 Installation Manual

Woodburning fireplace
Hide thumbs Also See for BE42:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
7KLV ¿UHSODFH XVHV 6/ 6HULHV &KLPQH\
2" CLEARANCE TO COMBUSTIBLES AND BUILDING INSULATION FROM CHIMNEY REQUIRED.
NOTICE:
DO NOT discard this manual!
Model(s):
WOODBURNING FIREPLACE
,QVWDOODWLRQ DQG VHUYLFH RI WKLV DSSOLDQFH VKRXOG EH SHUIRUPHG E\
TXDOLILHG SHUVRQQHO +HDUWK
)DFWRU\ 7UDLQHG RU 1), FHUWLILHG SURIHVVLRQDOV
Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23
Installation Manual
Installation and Fireplace Setup
+RPH 7HFKQRORJLHV UHFRPHQGV ++7
WARNING: If the information in these
LQVWUXFWLRQV LV QRW IROORZHG H[DFWO\ D ¿UH
or explosion may result causing property
damage, personal injury, or death.
• DO NOT VWRUH RU XVH JDVROLQH RU RWKHU ÀDP-
PDEOH YDSRUV DQG OLTXLGV LQ WKH YLFLQLW\ RI WKLV
RU DQ\ RWKHU DSSOLDQFH
• DO NOT RYHU¿UH 2YHU¿ULQJ ZLOO YRLG \RXU
warranty.
‡ &RPSO\ ZLWK DOO PLQLPXP FOHDUDQFHV WR FRP-
EXVWLEOHV DV VSHFL¿HG )DLOXUH WR FRPSO\ PD\
FDXVH KRXVH ¿UH
WARNING
HOT SURFACES!
*ODVV DQG RWKHU VXUIDFHV DUH KRW GXULQJ
RSHUDWLRQ $1' FRRO GRZQ
Hot glass will cause burns.
• DO NOT WRXFK JODVV XQWLO LW LV FRROHG
‡ 1(9(5 DOORZ FKLOGUHQ WR WRXFK JODVV
‡ .HHS FKLOGUHQ DZD\
‡ &$5()8//< 683(59,6( FKLOGUHQ LQ VDPH URRP DV
¿UHSODFH
‡ $OHUW FKLOGUHQ DQG DGXOWV WR KD]DUGV RI KLJK WHPSHUDWXUHV
+LJK WHPSHUDWXUHV PD\ LJQLWH FORWKLQJ RU RWKHU ÀDPPDEOH
materials.
‡ .HHS FORWKLQJ IXUQLWXUH GUDSHULHV DQG RWKHU ÀDPPDEOH
materials away.
WARNING
Fire Risk.
For use with solid wood fuel only.
2WKHU IXHOV PD\ RYHU¿UH DQG JHQHUDWH
SRLVRQRXV JDVHV LH FDUERQ PRQR[LGH 
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BE42 and is the answer not in the manual?

Questions and answers

Summary of Contents for Majestic BE42

  • Page 1 )DFWRU\ 7UDLQHG RU 1), FHUWLILHG SURIHVVLRQDOV WARNING Fire Risk. For use with solid wood fuel only. 2WKHU IXHOV PD\ RYHU¿UH DQG JHQHUDWH SRLVRQRXV JDVHV LH FDUERQ PRQR[LGH  Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 2: Table Of Contents

    ' 6HFXUH 2 VHW5HWXUQ ( ,QVWDOO &HLOLQJ )LUHVWRSV ) ,QVWDOO $WWLF ,QVXODWLRQ 6KLHOG G. Roof Penetration + ,QVWDOO &KDVH&KDVH 7RS , 7HUPLQDWLRQ &DS 5HTXLUHPHQWV - ,QVWDOO 7HUPLQDWLRQ &DS Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 3: Attention Installer

    Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed: Comments communicated to party responsible __________________________ by ______________________on _________ (Builder/Gen. Contractor) (Installer) (Date)  ‡ 5HY % ‡  Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 4: 3Urgxfw 6Shfl¿F

    State of California to cause birth defects or other reproductive harm. For more information go to: www. P65Warnings.ca.gov. Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 5: Getting Started

    4 ft. Decorative facing (1.22 m) off and trim ground level. Hearth extension Outside combustion air Factory-built fireplace Protective metal hearth strip(s) Figure 2.1 Typical Fireplace System Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 6: Design And Installation Considerations

    73 7/8 65 1/2 37 1/4 52 1/4 21 1/2 BE-42 perpendicular wall. 1219 1422 1876 1664 1327 Figure 2.2 Fireplace Locations Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 7: Rfdwlqj )Luhsodfh &Klpqh

    LQ FRROHU FOLPDWHV ‡ $YRLG RXWVLGH ZDOO :LQGZDUG /HHZDUG 1RW UHFRPPHQGHG LQ EDVHPHQW GXH WR KLJK QHJDWLYH SUHVVXUH FRQFHUQV WKDW HIIHFW GUDIW )LJXUH  5HFRPPHQGHG &KLPQH\ /RFDWLRQV Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 8: Tools And Supplies Needed

    5HSRUW WR \RXU GHDOHU DQ\ SDUWV GDPDJHG LQ VKLSPHQW • Read all the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety DQG EHQH¿W Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 9: Framing And Clearances

    7-1/2 in. 7-1/2 in. 14-1/8 in. (191 mm) (191 mm) (359 mm) Model # 23-3/4 11-7/8 BE-36 1041 29-3/4 14-7/8 BE-42 1067 1194 )LJXUH  $SSOLDQFH 'LPHQVLRQV Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 10: Minimum Clearances To Combustibles

    1/2 in. (13 mm) to back & sides of appliance 48 in. 1219 mm 0 in. to floor )LJXUH  &OHDUDQFHV WR &RPEXVWLEOH 0DWHULDOV Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 11: Construct The Chase

    ,Q FROG FOLPDWHV WKH ZDOOV RI WKH FKDVH VKRXOG EH LQVXODWHG WR WKH OHYHO RI WKH IDOVH FHLOLQJ DV VKRZQ LQ )LJXUH  7KLV ZLOO KHOS UHGXFH KHDW ORVV IURP WKH KRPH DURXQG WKH ¿UHSODFH Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 12: Frame The Fireplace

    * If interior of chase will be drywalled, add the thickness to ** Adjust header height for a raised floor under fireplace. )LJXUH  )UDPLQJ WKH )LUHSODFH Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 13: Protective Metal Hearth Strips

    Raised Platform 2 in. 1 in. (25 mm) min. (51 mm) overlap Floor 2 in. (51 mm) )LJXUH  3URWHFW WKH )URQW RI DQ (OHYDWHG 3ODWIRUP Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 14: Outside Air Kit (Optional)

    • Secure flex duct with screws or wire ties. )LJXUH  2XWVLGH $LU ,QVWDOODWLRQ )LJXUH  2XWVLGH $LU ,QVWDOODWLRQ ZLWK &ROG $LU 7UDS Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 15: Chimney And Termination Requirements

    14.5 ft (5.03 m) min. height/single offset-return 41-1/4 in. 20 ft. (6.10 m) min. height/double offset-return (1048 mm) 90 ft (27.4 m) max. height Effective Height Figure 4.1 Chimney Requirements Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 16: Vhwv5Hwxuqv

    3URSHU DVVHPEO\ RI DLUFRROHG FKLPQH\ SDUWV UHVXOW LQ DQ RYHUODS DW FKLPQH\ MRLQWV RI  LQ  PP  ( HFWLYH OHQJWK LV EXLOW LQWR WKLV FKDUW Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 17: Termination Requirements

    In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap. )LJXUH  0XOWLSOH &KLPQH\ /RFDWLRQV Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 18: Chimney Installation

    2 through ceiling or inch clearances. floor Figure 5.1 Typical Chimney System - Guidelines for Chimney System Installation Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 19: Assemble Chimney Sections

    9HUWLFDO VWUDLJKW UXQV RI FKLPQH\ PXVW EH VXSSRUWHG HYHU\  IW  P  Figure 5.2 Assembling Chimney Sections WARNING! Risk of Fire! DO NOT install substitute or damaged chimney components. Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 20: Install Ceiling Firestops

    ZKHQ WKHUH LV D URRP DERYH ‡ 8VH DQ DWWLF LQVXODWLRQ VKLHOG LI WKH FHLOLQJ LV LQVXODWHG 7KH FHLOLQJ ¿UHVWRS PD\ WKHQ EH DWWDFKHG DERYH RU EHORZ the joists. Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 21: Install Attic Insulation Shield

    WR HQVXUH SURSHU HQJDJHPHQW EHIRUH LQVWDOOLQJ WKH VXF- FHHGLQJ VHFWLRQV ,I WKH\ KDYH EHHQ FRQQHFWHG FRUUHFW- )LJXUH  ,QVWDOO $WWLF ,QVXODWLRQ 6KLHOG ¿UHVWRS EHORZ FHLOLQJ O\ WKH\ ZLOO QRW GLVHQJDJH ZKHQ WHVWHG Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 22: Roof Penetration

    WARNING! Risk of Fire! DO NOT caulk the pipe to the chase top collar. .018 (26 ga) min. ‡ &DXON DOO VHDPV WR SUHYHQW OHDNV Galvanized Chase Top Figure 5.9 Chase Top Construction Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 23: Termination Cap Requirements

    Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm). )LJXUH  ,QVWDOOLQJ D 75 5RXQG 7HUPLQDWLRQ &DS Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 24 2 in. (51 mm) Chase Top 4-3/4 in. (121 mm) Chase Chimney Pipe )LJXUH  ,QVWDOOLQJ &7$% &DS $GDSWHU Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 25: Shrouds

    3 in (76 mm) air space from bottom of shroud Chase Top to top of chase. )LJXUH  6KURXG 75 6HULHV FDS ZLWK QR 5DGLDWLRQ 6KLHOG Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 26: Mailbox Style Shroud

    Base Dimension  [  Min. Height Min. Opening Width Above Bottom of Termination Cap Min. Opening Width Min. Opening Height Figure 65 Roofed Style Shroud Dimensions Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 27: Finishing

    2 in. (51 mm) Figure 7.2 Decorative Facing Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 28: Hearth Extension, Building And Finishing

    4 in. (102 mm) minimum between bottom of fireplace opening and finished surface of hearth extension Model # %(  %(   )LJXUH  +HDUWK ([WHQVLRQ 'LPHQVLRQV Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 29: Vinyl Flooring

    6HDO JDSV EHWZHHQ WKH KHDUWK H[WHQVLRQ DQG WKH IURQW Figure 7.7 Raised Platform Hearth Extension-Finishing RI WKH ¿UHSODFH ZLWK D EHDG RI QRQFRPEXVWLEOH VHDODQW RU JURXW Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 30: Luhsodfh 2Shqlqj Dqg +Hduwk

    Finished 20 in. Min. Figure 7.9 Place Non-combustible Sealant Floor Hearth Extension Micore Noncombustible Material Protective Metal Hearth Strip Figure 7.8 Flush Hearth Extension Side View Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 31: Mantel And Wall Projections

    NOT cover any air sealant to prevent heat from being openings in the face drawn into the wall cavity. of the fireplace. )LJXUH  0DQWHO 6SHFL¿FDWLRQV Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 32 [305 mm] Fireplace Outside Opening Dimensions Model # BE-36 1041 BE-42 1067 1194 Figure 7.11 Mantel Leg, Surround or Wall Projection (acceptable on both sides of opening) Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 33: Fireplace Setup

    Repack beyond 4 in. (102 mm) insulation from fireplace side. knockout 4 in. (102 mm) Figure 8.1 Gas Line Installation Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 34: Reference Materials

    )LHOG &RQVWUXFWHG 6KURXGV 6HH ³:RRGEXUQLQJ Storm Collar 7HUPLQDWLRQ &DS´ &7$% $GDSWHU  0D\ EH XVHG ZLWK WKH IROORZLQJ FDSV Attic Shield Kit &7 6HULHV '7 6HULHV Attic Collar Attic Spacer Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 35 JB877 Chimney Joint Band 24-5/8 in. 10-1/2 in. 31 in. (625 mm) (267 mm) (787 mm) CB876 Chimney Joint Band 5) 5RRI )ODVKLQJ TR-TVK - Top Vent Kit &7$% Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 36 75 5RXQG 7HUPLQDWLRQ &DS 76763 6TXDUH 7HUPLQDWLRQ &DS 75% 5RXQG 7HOHVFRSLQJ 7HUPLQDWLRQ &DS 67 6TXDUH 7HUPLQDWLRQ &DS 7&7 7HUUD &RWWD &DS 75  5RXQG 7HOHVFRSLQJ 7HUPLQDWLRQ &DS Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 37 DTS134/DTS146 DTO134/DTO146 Decorative Caps DTO134 DTO146 22.7 1168 DTS134 21.18 DTS146 21.18 1168 Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 38: Optional Components

    4 in. (102 mm) i.d. 42 in. (1067 mm) LDSCP-M - Corner Post Kit (for custom size) Bifold Glass Doors LDS-BV Decorative Shroud '0 '0 Catalog #   LDS-BV Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...
  • Page 39 0DMHVWLF D EUDQG RI +HDUWK +RPH 7HFKQRORJLHV  WK 6WUHHW :HVW /DNHYLOOH 01  ZZZPDMHVWLFSURGXFWVFRP Majestic Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev N • 11/23...

This manual is also suitable for:

Be36

Table of Contents