Download Print this page

Advertisement

Quick Links

GL 40 / LD 01
Beurer GmbH • Söflinger Straße 218 • 89077 Ulm, Germany • www.beurer.com
www.beurer-gesundheitsratgeber.com • www.beurer-healthguide.com
Lancet needles / Lanzetten / lancettes / lancetas / lancette:
SteriLance Medical (Suzhou) Inc., No.168 PuTuoShan Road
New District, 215153 Suzhou, Jiangsu
PEOPLE'S REPUBLIC OF CHINA
Short instructions
Emergo Europe B.V., Westervoortsedijk 60
6827 AT Arnhem, The Netherlands
GL 40
EN

Advertisement

loading
Need help?

Need help?

Do you have a question about the GL 40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Beurer GL 40

  • Page 1 GL 40 Short instructions GL 40 / LD 01 Beurer GmbH • Söflinger Straße 218 • 89077 Ulm, Germany • www.beurer.com www.beurer-gesundheitsratgeber.com • www.beurer-healthguide.com Lancet needles / Lanzetten / lancettes / lancetas / lancette: Emergo Europe B.V., Westervoortsedijk 60 SteriLance Medical (Suzhou) Inc., No.168 PuTuoShan Road...
  • Page 2: Safety Information

    Safety information Before using the system for the first time Before your first blood glucose test read the complete instructions carefully. Check the measuring unit as per the instructions for use! Infection hazard The monitor and accessories may come into contact with human blood and are therefore possible sources of infection.
  • Page 3 Preparing the lancing device and monitor Inserting the lancet Unscrew cap from lancing device. Insert lancet into lancing device. Hold lancet by shaft and unscrew safety shield. Retain safety shield Place cap on lancing device and screw on tightly. Turn cap until arrow shows desired penetration depth. Withdraw clamping device until it snaps into place.
  • Page 4 Take a blood sample Lancing Position the lancing device firmly and slightly o -centre on the fingerprint. Press trigger button. The drop of blood obtained must be: • in the form of a drop and must not be smeared • at least 1.4 mm in size (original size ).
  • Page 5 Apply blood to test strip Hold the blood absorption slot of the test strip to the drop of blood until the slot is completely full and a beep sounds. Wait approximately 5 seconds until the measured blood glucose value is shown on the display.
  • Page 6 Evaluating critical results Very low blood glucose level Seek medical attention imme- < 20 mg/dL (< 1.1 mmol/L) diately. Low blood glucose level Have a snack. < 70 mg/dL (< 3.9 mmol/L) Follow your doctor’s instructions. mg/dL mmol/L High blood glucose level On an empty stomach >...
  • Page 7 High blood glucose level, possibly ketones Ketone test recommended. 16 7 > 240 mg/dL (> 13.3 mmol/L) Consult your doctor. mg/dL mmol/L Take another measurement using a new test strip. If the result is Very high blood glucose level identical, seek medical attention >...
  • Page 8: Messages On The Display

    Messages on the display Batteries empty. Replace all batteries. Temperature is outside the permit- Repeat the test with a new strip at room tempera- Ht or Lt ted range. ture +20 °C to +26 °C. Insert a new test strip that has not expired and Used or contaminated test strip.