  • Page 1 GL34 mmol/L Beurer GmbH Söflinger Straße 218 89077 Ulm, Germany • • 0344 www.beurer-medical.com...
  • Page 2 Safety information Before using the system for the fi rst time Before your fi rst blood glucose test read the complete instructions carefully. Infection hazard The monitor and accessories may come into contact with human blood and are therefore possible sources of infection. •...
  • Page 3 Preparing the lancing device and monitor Inserting the lancet Unscrew cap from lancing device. Insert lancet into lancing device. Hold lancet by shaft and unscrew safety shield. Retain safety shield Place cap on lancing device and screw on tightly. Inserting test strip Insert the test strip into the monitor with the electrode fi...
  • Page 4 Take a blood sample Lancing Rotate cap until the arrow points to the desired insertion depth. Pull trigger mechanism back until it clicks. Position the lancing device fi rmly and slightly off-centre on the fi ngerprint. Press trigger button. The drop of blood obtained must be: •...
  • Page 5 Apply blood to test strip Hold the blood absorption slot of the test strip to the drop of blood until the slot is completely full and a beep sounds. Wait approximately 6 seconds until the measured blood glucose value is shown on the display and audibly announced at the same time.
  • Page 6 Evaluating critical results Hypoglycaemia Seek medical treatment < 1.1 mmol/L immediately. Low blood glucose Have a snack. < 3.9 mmol/L Follow doctor’s recommen- dations. High blood glucose Seek medical advice. Fasting > 5.6 mmol/L 2 hours after a meal > 7.8 mmol/L...
  • Page 7 High blood glucose, possible ketones Ketone test recommended. > 13.3 mmol/L Ask your doctor. Very high blood glucose Repeat test with a new > 33,3 mmol/L test strip. If the value is still the same, seek immediate medical attention.
  • Page 8 Messages on the display Empty batteries. Replace all batteries. Temperature outside the Repeat test with a new test strip at room permissible range. temperature +20 °C to +25 °C. Used or contaminated test Insert new, unexpired test strip and repeat strip.