EU Declaration of Conformity
The Wolf ATEX LX-400E LinkEx
TM
meets all relevant provisions of the 2014/34/EU Explosive Atmospheres (ATEX
Equipment) Directive by virtue of the issued EU type examination certificate,
confirming compliance with all relevant harmonised standards and essential
health and safety requirements.
The Wolf ATEX LinkEx
LED Temporary Emergency Luminaire is a leadlamp
TM
with an emergency illumination function powered by a NiMH rechargeable
battery and is normally powered by a cabled 18-55AC or 90-264AC power
source. It is constructed with a durable enclosure construction of polycarbonate
with polyurethane protective rings. Approval is as Group II, Category 2
equipment for use in zone 1 & 2 potentially explosive gases, vapours, mists and
dusts where the T4 temperature class/135ºC maximum surface temperature
permits.
Certification/Approval Code:
All non-IS switch models except LV CEAG.
II 2GD
Ex eb mb IIC T4 Gb
Ex tb IIIC T135°C Db IP6X
All IS switch models except LV CEAG.
II 2GD
Ex eb ib mb IIC T4 Gb
Ex ib tb IIIC T135°C Db IP6X
Ta = -20°C to +55°C
(or +45°C when the LX-621 optional Protection Cover is fitted)
EU Type examination certificate: CML 18ATEX3371X
Notified Body:
SGS FIMKO OY, PO Box 30 (Särkiniementie 3),
00211, Helsinki, Finland
0598
EU Notified body number:
Harmonised standards applied:
EN IEC 60079-0:2018, EN IEC 60079-7:2015+A1:2018,
EN 60079-18:2015+A1:2017, EN 60079-31:2014
Ingress protection level IP67 to EN60529:1992. Some variants of plugs/
sockets may reduce the Ingress Protection rating. e.g. ATX & STAHL IP66.
ATEX LinkEx
LED Leadlamps are certified compliant with the 2014/30/EU
TM
EMC Directive to the harmonised standards: - EN 55015: 2019,
EN 61547: 2009, EN 61000-3-2:2014, EN 61000-3-3:2013
The Wolf LX-400 LinkExTM LED Temporary Emergency Luminaire is compliant
the 2011/65/EU RoHS Directive to the designated standard EN IEC 63000:2018.
This declaration is issued under the sole responsibility of Wolf Safety Lamp
Company.
Alex Jackson – Managing Director
Wolf Safety Lamp Company Ltd., Sheffield, S8 0YA, UK.
Dated 01 January 2024.
WOLF SAFETY LAMP COMPANY
Saxon Road Works, Sheffield, S8 0YA, England
LED Temporary Emergency Luminaire
Non-IS switch LV CEAG.
II 2G
Ex eb mb IIC T4 Gb
IP54
IS switch LV CEAG.
II 2G
Ex eb ib mb IIC T4 Gb
IP54
Wolf LinkEx
LED Temporary Emergency Luminaire
TM
Operation and Maintenance Instructions
UK Declaration of Conformity
The ATEX LX-400E LinkEx
the statutory requirements of the Equipment and Protective Systems Intended
for use in Potentially Explosive Atmospheres Regulations 2016, UKSI 2016/1107
as amended by UKSI 2019/696 by virtue of the issued UKEX type examination
certificate, demonstrating compliance with all relevant designated standards
and essential health and safety requirements.
Certification/Approval Code:
All non-IS switch models except LV CEAG.
II 2GD
Ex eb mb IIC T4 Gb
Ex tb IIIC T135°C Db IP6X
All IS switch models except LV CEAG.
II 2GD
Ex eb ib mb IIC T4 Gb
Ex ib tb IIIC T135°C Db IP6X
Ta = -20°C to +55°C
(or +45°C when the LX-621 optional Protection Cover is fitted)
Approved Body:
Approval body number:
UK Type examination certificate: CML 21UKEX3644X
Designated Standards Applied:
EN IEC 60079-0:2018, EN IEC 60079-7:2015+A1:2018,
EN 60079-18:2015+A1:2017, EN 60079-31:2014
The Wolf LX-400 LinkEx
statutory requirements of the UK EMC Regulations 2016, UKSI 2016/1091 as
amended by UKSI 2019/696 to the relevant designated standards
EN 55015: 2019, EN 61547: 2009, EN 61000-3-2:2014, EN 61000-3-3:2013
The Wolf LX-400 LinkExTM LED Temporary Emergency Luminaire is compliant
with the Restriction of the Use of Certain Hazardous Substances in Electrical
and Electronic Equipment Regulations 2012, UKSI 2012/3032 to the designated
standard EN IEC 63000:2018.
This declaration is issued under the sole responsibility of Wolf Safety Lamp
Company.
IECEx Scheme Certification
Certificate number:
Certification/Approval Code:
All non-IS switch models except LV CEAG.
Ex eb mb IIC T4 Gb
Ex tb IIIC T135°C Db IP6X
All IS switch models except LV CEAG.
Ex eb ib mb IIC T4 Gb
Ex ib tb IIIC T135°C Db IP6X
Ta = -20°C to +55°C
(or Ta = -20°C to +45°C when the LX-621 optional Protection Cover is fitted)
Standards applied:
IEC60079-31:2013
IMPORTANT: SPECIAL CONDITIONS FOR SAFE USE (X)
1. The user/installer shall ensure that, when the Luminaire is fitted with a
previously certified plug or socket that has associated special conditions for
safe use, they shall take into account any restrictions or conditions for safe use
that are applicable to these devices.
2. Linkable lamps fitted with Marechal sockets are certified for low impact risk
use only, do not expose to shocks greater than 4 joules.
Please Retain - Read Before Use
LED Temporary Emergency Luminaire meets all
TM
SGS Baseefa Ltd, Rockhead Business Park,
Staden Lane, Buxton, SK17 9RZ, UK.
1180
LED Temporary Luminaire also meets all the
TM
Alex Jackson – Managing Director
Wolf Safety Lamp Company Ltd., Sheffield, S8 0YA, UK.
Dated 01 January 2024.
IECEx CML 18.0197X
IEC60079-0:2017, IEC60079-7:2017, IEC60079-18:2017,
Page 1 of 6
Non-IS switch LV CEAG.
II 2G
Ex eb mb IIC T4 Gb
IP54
IS switch LV CEAG.
II 2G
Ex eb ib mb IIC T4 Gb
IP54
Non-IS switch LV CEAG.
Ex eb mb IIC T4 Gb
IP54
IS switch LV CEAG.
Ex eb ib mb IIC T4 Gb
IP54
Need help?