FO3 - RPM locking: (Tach input is required for this option to operate properly.) This option will
provide a door lock output at approximately 20% RPM over the programmed idle tach output. (i.e.
program tach at 1000 rpm and doors will lock at a sustained 1200 rpm when moving.) The CMX will
also provide a door unlock output as soon as the key is turned off or the parking brake is set (must
have parking brake input connected or provide parking brake input from data module)
1-10 Auto Relock:
FO1 - Off: (default)
FO2 - 30 seconds: This option allows the CMX to automatically relock/rearm 30 seconds after
CMX has been disarmed/unlocked only if no zones have not been opened.
FO3 - 60 seconds: This option allows the CMX to automatically relock/rearm 60 seconds after
CMX has been disarmed/unlocked only if no zones have not been opened.
FO4 - 5 minutes: This option allows the CMX to automatically relock/rearm 5 minutes after it has been
disarmed/unlocked only if no zones have not been opened.
1-11 Ignition / Accessory Upon Unlock: This feature will provide an Ignition/Accessory output with
unlock/disarm command. (NOTE: will not provide pulse output with disarm before remote starting)
FO1 - Off: (default)
FO2 - Ignition (+) and (-) pulse output with disarm: This option will pulse both (+) and (-) ignition
wires upon unlock/disarm. Most new Ford vehicles require ignition pulsed + immobilizer with unlock
to disarm the factory alarm.
FO3 - Accessory (+) and (-) pulse output with disarm: This option will pulse both (+) and
(-) accessory wires upon unlock/disarm.
FO4 - Ignition (+) and (-) pulse and Accessory (+) and (-) pulse output with disarm: This option will
pulse both (+) and (-) ignition and accessory wires upon unlock/disarm. Some new Ford vehicles
require ignition and accessory pulsed + immobilizer with unlock to disarm the factory alarm.
Important: Also used in cases where the vehicle's radio may turn on and stay on until the door is opened
when accessory is pulsed.
1-12 OEM Remote status update: This feature disables the arming, disarming, and remote start
confirmation updates to any Firstech 2 Way LCD when using an OEM remote.
FO1 - Off: (default) This feature disables the page back update to the 2 Way Firstech remote when
your interface module provides OEM remote status updates to the CMX.
FO2 - On: This option will enable the remote page back to update the CM status when using an
OEM remote. This feature is only available when CM is used with a compatible interface module
(Blade AL, ALCA)
1-13 Double pulse disarm: This feature enables the FAD output. It will pulse 2 times with a single disarm
command.
FO1 - Off (default): Standard single pulse output on the FAD wire. (orange/white by default)
FO2 - On: This feature will generate a double pulse output on the FAD wire.