Download Print this page

Advertisement

Quick Links

Firstech, LLC.
21903 68th Ave S.
Kent, WA 98032
Phone. 888-820-3690
Fax. 206-957-3330
Please visit www.install.myfirstech.com for additional installation resources

Advertisement

loading
Need help?

Need help?

Do you have a question about the CM-X and is the answer not in the manual?

Questions and answers

Summary of Contents for Firstech CM-X

  • Page 1 Firstech, LLC. 21903 68th Ave S. Kent, WA 98032 Phone. 888-820-3690 Fax. 206-957-3330 Please visit www.install.myfirstech.com for additional installation resources...
  • Page 2: Table Of Contents

    Feature Option descriptions _______________________________________________ page 37 Option programming procedures ___________________________________________ page 65 Troubleshooting and Diagnostics ___________________________________________ page 69 FAQ _________________________________________________________________ page 71 Website resources _______________________________________________________ page 74 NOTES _______________________________________________________________ page 75 Copyright 2022 Firstech, LLC. “Goonies never say die! Page 3 ”...
  • Page 3: Cmx Back Label Image

    CMX is the Solution https://install.myfirstech.com CMX Master Guide Copyright 2022 Firstech, LLC. “Goonies never say die! Page 3 ”...
  • Page 4: Introduction

    Introduction Thank you! For selecting a Firstech solution as your product of choice. The following manual is a complete Master guide to the CMX universal Control Module and is intended for experienced and authorized Firstech technicians only. If you need any further technical support, please call us at 888-820-3690 ext. 203 or visit our website at https://install.myfirstech.com...
  • Page 5: Installation Basics

    CMX Master Guide Installation Basics If you are new to installing Firstech Series Remote Starts and/or Alarms, we highly recommended that you thoroughly review this manual to installing your first unit. Remote Programming: You must code remotes to this system before anything will function. Begin by cycling the ignition ON and OFF 5 times within 10 seconds then press and release Lock button (half second) on the first remote, and then press and release lock button (half second) on the second remote.
  • Page 6: Control Module Stats

    STEP 2: Within a 10 second period after the 5th ignition cycle tap (a quick 0.5 second press and release) the Lock button on the Firstech remote. The parking lights will flash once to confirm the transmitter has been coded. Repeat step 2 for each additional remote, up to 4. Note: if you only have 2 remotes, please program each remote twice.
  • Page 7: Valet Mode

    CMX is the Solution https://install.myfirstech.com CMX Master Guide Remote programming procedure: PTS (Push to Start vehicles) application STEP 1: Set the vehicle to the ignition or “ON” position STEP 2: Within 5 seconds push to the “OFF” position STEP 3: Within 5 seconds set the vehicle to the ignition or “ON” position (do not start) STEP 4: Within 5 seconds press and release the foot brake 3 times *parking lights will flash 1 time to indicate remote programming is enabled STEP 5: Tap (a quick 0.5 second press and release) the lock button on the remote * the parking lights...
  • Page 8 CMX is the Solution https://install.myfirstech.com CMX Master Guide 4. Drone Mobile app will allow a user to enable/disable VALET mode within the vehicle settings section. 1. Open the Drone Mobile app 2. Open settings 3. Open “Vehicles” 4. Select Vehicle 5.
  • Page 9: Placement And Use Of Components

    Antenna and Cable (Included with RF kits that are sold separately) Firstech antennas are calibrated for horizontal installation at the top of the windshield. The cable that connects the antenna to the control module must be free from any pinches or kinks. Installing the antenna in areas other than the windshield may adversely affect the effective transmitting distance of the remotes.
  • Page 10 CMX is the Solution https://install.myfirstech.com CMX Master Guide STEP 2: Turn ignition to the ‘ON’ position and leave driver’s door open. (Door Input must be connected) STEP 3: Hold your finger over the ‘Red Circle’ icon for 3 seconds. STEP 4: When the siren chirps and LEDs flash in a circular pattern, tap on your first number. (Hold the number for 2.5 seconds to choose 6 through 10.) After choosing your first number you will get 1 siren chirp and LEDs will flash in a circular pattern.
  • Page 11 LED’s will flash 3 times (the siren will chirp 3 times if installed) and an alert will be sent to any Firstech 2way LCD remote or Drone that may be connected to the CM.
  • Page 12 DAS-II Programming Procedure STEP 1: Turn the ignition to the ‘on’ position STEP 2: Send Unlock command 2 times (unlock => unlock) using any Firstech remote, Drone, or OEM remote with “OEM remote control” supported over data. At this time the DAS-II display will initialize and stay powered up for at least 5 minutes or until ignition is off.
  • Page 13 CMX is the Solution https://install.myfirstech.com CMX Master Guide Copyright 2020 Fi rstech , LLC. “Hello, my name is Inigo Montoya..” Page 13...
  • Page 14 To set Instant Trigger Zone 2 a. Repeat Steps 1 and 2 b. Tap the Unlock button on your Firstech remote, the parking lights will flash 2 times. c. After you get two parking light flashes, tap the vehicle. You will get siren chirps 1-most sensitive through 10-least sensitive.
  • Page 15 STEP 9: You are now ready to test the DASII. FT-RFID (sold separately as an RF-kit) The FT-RFID function, now included with 2 of the latest 2-way remotes from Firstech, will unlock/disarm the vehicle when in range of the antenna (ANT-2WSF).
  • Page 16 Thermistor (Temperature Sensor)(Included with 2 way LCD RF kit or Done) Every 2 Way LCD Firstech RF kit includes an optional thermistor, which must be plugged into the blue 2 pin port of the CMX to use properly. (we also offer optional temp sensor extensions for more accurate temperature.
  • Page 17: Common Procedures

    CMX is the Solution https://install.myfirstech.com CMX Master Guide Common Procedures Programmable Settings Caution: Programmable settings affect the polarity or output function of certain outputs. If these settings are used incorrectly, damage to the vehicle and /or control module may occur. Setting 1: Door input Feature 4-09 (Door Trigger Polarity) Determines the polarity of the door trigger input wire (red/white).
  • Page 18 The default engine sensing mode is tach. In cold weather climates we recommend using an injector wire or tach signal provided by a compatible interface module for tachometer sense. IMPORTANT: The remotes must be coded prior to programming tach. Firstech recommends using a digital multimeter when testing for tach.
  • Page 19 CMX is the Solution https://install.myfirstech.com CMX Master Guide Alternator Sensing Alternator sensing is another method the remote start can utilize to determine if the engine is running. This is option requires a wire (yellow/black) connection to the alternator stator wire. NOTE: there is no programming procedure needed for this option STEP 1: Change Option 2-10 to setting 2 - Alternator sensing.
  • Page 20: Manual Transmission

    IMPORTANT: Do not install a remote start in manual transmission vehicles with convertible / removable tops and in user ’s vehicles that leave their windows down. Firstech or their authorized dealers will not assume any responsibility for improper use or install.
  • Page 21 If the vehicle’s engine does not shut off, check the door trigger connection, or wait for the factory dome-light to go out. The Firstech system is in reservation mode and the vehicle is ready to safely remote start. (For PTS vehicles please exit vehicle after entering...
  • Page 22: Wiring Descriptions

    CMX is the Solution https://install.myfirstech.com CMX Master Guide Wiring Descriptions Connector 1 (CN1): 8-Pin High current power harness included (NOTE: Please see FT-LC1 for a low current version of CN1) Pin 1 Red - Constant 12V positive (+) power input (25A MAX): (This input provides power to the CM processor, Ignition 1, and accessory ports) This wire MUST be connected.
  • Page 23 CMX is the Solution https://install.myfirstech.com CMX Master Guide Connector 2 (CN2), 8-Pin (NOT INCLUDED): Low Current power harness (10A MAX) NOTE: This is a low current power harness and is NOT designed to be used in High current applications or in combination with CN1 (the high current power harness). Pin 1 Red –...
  • Page 24 CMX is the Solution https://install.myfirstech.com CMX Master Guide Connector 3 (CN3), Black 20-Pin: Blade Connector This connector is used only if you are installing a Blade-AL or Blade-TB. The wiring harness for this connector only comes with the Blade cartridge. Please refer to the Blade install guide for wire description http://myfirstech.idatalink.com.
  • Page 25 CMX is the Solution https://install.myfirstech.com CMX Master Guide Pin 7 Blue - [POC 4] Unlock 250mA, 800mS (-) negative output: This is an optional output that will provide only a negative (-) output pulse for unlocking doors. System will unlock doors and disarm alarm. IMPORTANT: You must reverse polarity for (+) trigger door lock systems using the FT-DM700, FT- DM600 or relays.
  • Page 26: Connector Descriptions

    Connector Description Connector 5 (CN5) Brown 4 Pin (UART data port) data to data only This connector is available for use with Firstech accessories that support data to data communication. This data port will support with the ANT-1WAF RFID antenna.
  • Page 27 CMX is the Solution https://install.myfirstech.com CMX Master Guide Connector 6 (CN6), Gray 4 Pin (UART data port) Drone/Fortin data to data only Pin 1 (B+) - Constant 12V positive (+) output Pin 2 (B-) - Ground (-) output Pin 3 (RX) - Input, this wire receives data Pin 4 (TX) - Output, this wire transmits data Connector 7 (CN7), Black 4-Pin (UART data Port) ADS/Drone data to data This connector is used for updating control modules via...
  • Page 28 (FT-DM600 or FT-DM700) Pin 1 None - 12v B+ constant output: available when using a Firstech door lock Module DM600, DM700 Pin 2 Violet/White - Trunk release 250mA, 800mS negative (-) output: This is an optional output that will release the trunk.
  • Page 29 CMX is the Solution https://install.myfirstech.com CMX Master Guide Connector 13 (CN13), 4-Pin (Pre-wired DAS Sensor) Pin 1 Black - Negative (-) ground when armed (GWA). Pin 2 White - 2nd stage negative (-) input. (Instant trigger) Pin 3 Red - 12V positive (+) output. Pin 4 Yellow - 1st stage negative (-) input.
  • Page 30: Feature Tables

    CMX is the Solution https://install.myfirstech.com CMX Master Guide Feature Option Tables Option group #1 Option Setting Feature Default(I) Option (II) Option (III) Option (IV) Unlock before, Lock Lock After Shutdown Lock After Start Only after, starting. Only Lock / Unlock pulse 0.8 sec 2.5 sec 0.125 sec...
  • Page 31 CMX is the Solution https://install.myfirstech.com CMX Master Guide Option group #2 Option Setting Feature Default(I) Option (II) Option (III) Option (IV) Optimal Tach Tach Threshold Previous Tach Method Threshold Turbo Timer mode. 2 Min 1Min 4 Min Wait to start Diesel wait to start 3~99 sec (12sec Default) 7 sec...
  • Page 32 CMX is the Solution https://install.myfirstech.com CMX Master Guide Option group #3 Setting Feature Default(I) Option (II) Option (III) Option (IV) Constant Output While Flashing Output While Off While Remote Off While Lock and Parking lights Control Remote Started Remote Started Started Unlock Only Siren/horn output timing...
  • Page 33 CMX is the Solution https://install.myfirstech.com CMX Master Guide Option group #4 Setting Feature Default(I) Option (II) Option (III) Option (IV) Aux 1 output 0.5sec Latch 0.5 sec Pulse + Program Program Aux 2 output 0.5sec Latch 0.5 sec Pulse + Program Program Aux 1 output Control By Remote...
  • Page 34 CMX is the Solution https://install.myfirstech.com CMX Master Guide Special Option group #1 S-#1 Special feature group 1 Setting Value Diesel timer 3 ~ 99 [seconds] AUX1 output time 1 ~ 99 [seconds], LA(Latch), 1~15 [minutes] (with OP500 update .31+) AUX2 output time 1 ~ 99 [seconds], LA(Latch), 1~15 [minutes] (with OP500 update .31+) AUX3 output time 1 ~ 99 [seconds], LA(Latch), 1~15 [minutes] (with OP500 update .31+)
  • Page 35 CMX is the Solution https://install.myfirstech.com CMX Master Guide Special Option group #2 Special Feature group 2 Setting Value S-#2 Programmable (-) Output Options Channel POC #1 (Default: Starter-kill) 2nd LIGHT [ 1 ] Aux1 [ 10 ] Status-2 [ 19 ] Trunk Release [ 28 ] POC #2 (Default: Horn) 2nd START [ 2 ]...
  • Page 36 CMX is the Solution https://install.myfirstech.com CMX Master Guide Special Option group #4 Special Feature group 2 Setting Value High Current Programable S-#4 Options ( + ) Output Channel HCP #1 (Default: Parking light) 2nd LIGHT [ 1 ] DOME LIGHT [ 9 ] Lock [ 25 ] 10A MAX OUPUT HCP #2 (Default: ACC)
  • Page 37: Feature Option Descriptions

    CMX is the Solution https://install.myfirstech.com CMX Master Guide Feature Option Descriptions FO = Feature Option 1-01 Unlock before, Lock after: FO1 - Off FO2 - On: Sends an unlock command as soon as the remote start sequence is triggered then send a relock command as soon as the CMX has confirmed remote start success.
  • Page 38 FO1 - Off: (default) FO2 - On: This option (when activated with the Firstech remote or Drone) will provide a door lock output when the foot brake is applied, or 12 Volts is applied to the foot brake input on the CMX. The...
  • Page 39 Firstech 2 Way LCD when using an OEM remote. FO1 - Off: (default) This feature disables the page back update to the 2 Way Firstech remote when your interface module provides OEM remote status updates to the CMX.
  • Page 40 1-16 Siren/Horn mute control: this feature allows the installer to enable or disable the siren/horn mute control. The mute feature will silence the siren or horn during arm, disarm, and start from the Firstech remote. FO1 - Disabled: (default) will not allow for the Firstech remote or Drone Mobile to mute the siren or horn output.
  • Page 41 FO2 - 2 Minutes: This option allows for a 2-minute run time after Turbo Mode has been engaged. To engage, set the e-brake, remove key, exit vehicle, and lock with the Firstech remote or accessory. Note: when using Turbo Mode with a manual transmission, the CMX will NOT lock the doors automatically.
  • Page 42 Note: this option will also allow the CMX to accept a 3-pulse input from OEM remote commands through data. 2-05 Cold or Hot Start: Note: the Firstech thermistor temp sensor must be connected to the CMX in order to use these options. This feature turns on the cold/hot Timer start features.
  • Page 43 CMX is the Solution https://install.myfirstech.com CMX Master Guide FO3 - Reserved Timer: (runtime based on feature 2-07 option setting) Note: 2-way LCD remote required. This option will allow the user to set a predetermined time to remote start on the 2 ways LCD remote.
  • Page 44 CMX is the Solution https://install.myfirstech.com CMX Master Guide FO4 - 104° F/40° C (default) PROGRAMMABLE 20 ~ 65 [°C] / 68 ~ 150 [°F]: (using the OP500 programmer with software v.30 or newer that can be found at www.install.myfirstech.com) will activate the start sequence at the end of the time cycle (set by feature 2-06 option setting) if temperature is at or above this temperature.
  • Page 45 2-13 Timer Mode: (Note: Must be set to on to operate timer mode). This feature enables the user to activate and deactivate Timer Mode (see option 2-06) using the Firstech remote or accessory (see the user manual for that remote for instructions).
  • Page 46 CMX is the Solution https://install.myfirstech.com CMX Master Guide 2-15 Reservation Mode “Sets With”: This feature will allow the user to customize the process used to complete reservation mode (manual transmission set up mode) see below for options. FO1 – Last Door Closed (doors lock before shutting down): (default) (actions required within 5 minutes) This option will shut the vehicle off once the last door/zone has closed and lock the doors a few seconds BEFORE the engine shuts off.
  • Page 47 CMX is the Solution https://install.myfirstech.com CMX Master Guide 3-02 Confirmation chirps: This feature will allow the user to select a shorter siren or horn output time to simulate a quieter arm/disarm/start output. FO1 - 30mS: This is a 30 millisecond siren output with arm, disarm, and start confirmation chirps. It will produce a “medium”...
  • Page 48 While the vehicle is running with the key and the panic mode is activated using any Firstech 4 button or 2-way LCD remote, the CMX will enable the ignition interrupt relay so the vehicle cannot be re-started. Note: When using ignition-kill on manual transmission vehicles feature 3-04 must be set to option 2 will need to be utilized.
  • Page 49 FO1 - Off: (Default) This option will prevent the user form activating AUX 3-7 with the Firstech 2way LCD remote. FO2 - On: This feature will allow the user to enable AUX 3-7 which can be activated using a Firstech 2-way LCD remote. (Please refer to the remote users guide for specific AUX 3-7 activation process) Copyright 2020 Fi rstech , LLC.
  • Page 50 FO4 – AUX 1: This option will allow the user to activate/deactivate the Defrost outputs using the AUX 1 function from any Firstech remote or Drone. NOTE: This feature does not use an AUX output 3-14 Defrost output Timing: This feature controls the output timing of POC setting 17, defrost. Note: POC setting 21 defrost 2 is has a fixed pulsed output and is NOT affected by this feature.
  • Page 51 CMX. RPS Touch will support a 4 digit code that when entered can be used to arm/lock and disarm/unlock a CMX or page a Firstech remote or accessory. Please refer the RPS section of this manual or the RPS product manual for installation and operation of the RPS touch hardware.
  • Page 52 CMX is the Solution https://install.myfirstech.com CMX Master Guide -IF the user needs to disable the N/O secure start output for some reason, you can put the CMX into Vale Mode. While in Valet mode the Secure Start Output will activate any time a door is opened, (or when disarmed/unlocked) allowing the PTS button to function normally.
  • Page 53 FO1 - Remote: (default) This option allows AUX 1 (output time based on feature 4-01) to be triggered by any 4 button Firstech remote or drone. FO2 - With Disarm: this option will trigger AUX 1 (output time based on feature 4-01) any time the CMX is unlocked/disarmed.
  • Page 54 FO1- On: (default) this option will require the user to perform an additional step before activating AUX output using any Firstech 4 button or 2-way LCD remote (2way remotes with Roman numeral buttons will require a 0.5 second tap of button IV before activating any of the AUX outputs.2Way LCD remotes with lock/unlock/trunk/start icons on the buttons use the start button for the same.
  • Page 55 CMX is the Solution https://install.myfirstech.com CMX Master Guide FO4- 1000mS (1 sec): When using POC SV 30 the CMX will provide a negative output (on) to activate the hazard light circuit. 1000mS after the first output the CM will produce another output (off) to deactivate the Hazard Light circuit.
  • Page 56 To wake up the antenna the user must unlock/disarm using a Firstech accessory, power ignition or trigger the alarm. FO4 - 72hrs (3 days): This option will allow the antenna to power down 72hrs after being armed. Note: once the antenna has powered down, 1 Way operation to the vehicle will stop.
  • Page 57 Drone. FO2 - On + Start: This option will provide an alert to any Firstech 2 Way LCD remote or Drone when the vehicles battery voltage (at the CMX power connector) drops to 11.7volts. In addition to the alert the user can active the Timer mode (please refer to this manual for timer mode feature description) to enable the low battery start function.
  • Page 58 CMX is the Solution https://install.myfirstech.com CMX Master Guide Special Option Groups 1, 2, 3 and 4 IMPORTANT: The OP500 is required to change settings in Special Option Groups 1 and 2. Special Option Group 1 SO1- Diesel Timer: (Option 2-03 must first be set to setting 2.) This special option allows a specific wait to start time (in seconds) to be programmed.
  • Page 59 CMX is the Solution https://install.myfirstech.com CMX Master Guide Special Option Group 2 This special option group allows you to select the output setting of the Programmable Output Channel (POC) wire. For example, if you want to set POC #5 (default setting status out with setting value of 0) to Aux 1, you will need change special option 5 to setting value 10.
  • Page 60 250mA (-) negative output (based on AU3 setting) when AUX3 is triggered, AUX3: using a Firstech 2-way LCD remote (please refer to remote users guide for activation steps), on any POC programmed with this setting. (Feature 3-11 must be set to option 2)
  • Page 61 Once the system senses Ignition on , it will remain latched on until Ignition is off. Once ignition is off it will remain latched for the selected time based on feature 3-18 or until the system is armed/locked using a Firstech remote, Drone, or KP sensor.
  • Page 62 CMX is the Solution https://install.myfirstech.com CMX Master Guide SV 33 – Secure Start N/C: Provides a 250mA timed output that can be used to manage an FTI-SPTS vehicle PTS button disable harness. It will output at the exact moment an alarm event is triggered and remain active based on the time selected using feature 3-18.
  • Page 63 CMX is the Solution https://install.myfirstech.com CMX Master Guide SV 6 - (-) Trigger Start INPUT: This setting allows for any PIC programmed with value 6 to be used as a (-) negative Remote Start Trigger Start INPUT. SV 7 - (-) Glow Plug INPUT: This setting allows for any PIC programmed with value 7 to be used as a Glow Plug INPUT for diesel wait to start function.
  • Page 64 CMX is the Solution https://install.myfirstech.com CMX Master Guide SV 19 - (-) AUX 2 Trigger INPUT: This setting allows any PIC programmed with value 19 to be used to activate AUX2 output (timing output based on feature 4-02) with a Pulsed or latched ground/negative source.
  • Page 65 SV10 - AUX 1: provides a (+) positive output on any HCP programmed with this setting when AUX 1 is triggered by any Firstech remote or Drone. Timing outputs will be based on feature 4-01, 4-03, 4-05, and AU1 settings.
  • Page 66: Option Programming Procedures

    How to Program Options There are two ways to set options on the CMX control modules. You can use the FT-OP500-KIT or most Firstech remotes. The remotes include 4 or 5 buttons 1- and 2-Way remotes. Option Programming Using the FT-OP500-KIT The OP500 can be used to change anything in the Option Tables.
  • Page 67 CMX is the Solution https://install.myfirstech.com CMX Master Guide STEP 4: Push the valet button 5 times holding it on the 5 time for the following time lengths to reach the desired feature group: 1) 2 seconds → Option Group #1 (w/ light flash 1 time and siren/horn 1 chirp) 2) 4 seconds →...
  • Page 68 CMX is the Solution https://install.myfirstech.com CMX Master Guide How to Program Options with 5 Button 2-Way Remotes Wait for chirp or park light flash between each button combination hold (F + Trunk) for 3 seconds Tap Key Tap Lock Tap Unlock Tap Trunk Tap Key Option...
  • Page 69: Troubleshooting And Diagnostics

    CMX is the Solution https://install.myfirstech.com CMX Master Guide How to Program Options with 4 button 2 Way Remotes Wait for chirp or park light flash between each button combination hold Lock + Unlock for 3 seconds Hold Trunk Tap Key Tap Lock Tap Unlock Tap Key...
  • Page 70 CMX is the Solution https://install.myfirstech.com CMX Master Guide Troubleshooting Remote Start Error Codes If the remote start fails to start the vehicle, the parking lights will flash three times immediately. Following those two flashes the parking lights will flash again corresponding to the error table below: Number of Parking Light Remote Start Error...
  • Page 71: Faq

    CMX is the Solution https://install.myfirstech.com CMX Master Guide Number of Reservation Mode Diagnostics Parking Light Flashes Tach has been lost or interrupted while reservation mode was setting. Tach is present after reservation mode completed. E-brake signal has been lost before or after reservation mode completed Foot Brake was triggered before or after reservation mode completed...
  • Page 72: Frequently Asked Questions

    CMX is the Solution https://install.myfirstech.com CMX Master Guide Frequently Asked Questions I have everything hooked up and the system will not respond. A: The remotes need to be programmed. Review the “Common Procedure” section of this manual. When remote starting, the siren chirps 3 times and parking lights flash 3 then 1 time. A: You must program tach before remote starting.
  • Page 73 CMX is the Solution https://install.myfirstech.com CMX Master Guide All my connections are made, and remotes programmed, how do I program the tach? A: Review the “Common Procedures” section of this manual. You must have your remotes programmed, start your vehicle, then hold the remote start button. Vehicle should chirp and/or flash once if it programs, three times if it does not like the tach source.
  • Page 74: Technical Support Contacts

    WARNING: There should be no wiring routed around any pedals which can cause a driving hazard Technical Support Contacts Firstech technical support is reserved for authorized dealers ONLY consumers must contact client services for assistance. Monday - Friday: 888-820-3690 (7:00 am – 6:00 pm Pacific Standard Time)
  • Page 75 Tech Support page Facebook access: https://www.facebook.com/groups/firstechfeed Vehicle wiring database: http://www.install.myfirstech.com/ Operation and training videos https://www.youtube.com/channel/UCvLp0NC-DQnoPJVly7do5Kg Dealer activation/flashing sites: Drone activation account: https://accounts.dronemobile.com Idatalink and Firstech flashing site: http://myfirstech.idatalink.com http://arcticstart.idatalink.com http://maestro.idatalink.com/ Copyright 2020 Fi rstech , LLC. “Hello, my name is Inigo Montoya..” Page 75...
  • Page 76: Notes

    CMX is the Solution https://install.myfirstech.com CMX Master Guide NOTES: Write that shit DOWN! Copyright 2020 Fi rstech , LLC. “Hello, my name is Inigo Montoya..” Page 76...
Save PDF