……………………………………………………………………………………………………………. Replacing Drum / Motor Please be advised explicitly that we, Tacony Corporation, cannot accept any legal claims out of the contents of this manual. If repair work has to be performed, make sure that only genuine parts are used. Genuine parts only may guarantee continuous and dependable operation of your machine.
General Safety Instruction General Guidelines Never collect explosive fluids, undiluted • This machine is for WET scrubbing only. acids and solvents. This includes: gasoline, • Apart from information contained in this manual, paint thinners or fuel oil, which-when generally applicable legal provisions for safety and combined with air, may form explosive prevention of accidents mush be adhered to.
Operating the Machine Before the washing operation starts Warning! Pre-sweep the floor to remove debris before using the Multiwash. 1. Verify that the brushes are fitted properly. 2. Fill fresh water tank with cleaning solution (diluted with water). 3. Insert the plug into a grounded 3-prong outlet. Recommended washing sequence 1.
Care of the Machine Warning! Before cleaning the scrubber, switch off the machine and unplug from the electrical supply. 1. Move the Transport / Working mode control knob to BOTTOM (Transport) position. 2. Disconnect the power supply by unplugging the electrical plug and loop the cable over the cable holders on the handle.
Care of the Machine MAINTENANCE - CONTINUED • Wiper Blade • After years of use, the wiper blade may wear. If this occurs, the water collection performance will decrease. It should be replaced by an authorized service agent. • Solution Tank Filter •...
Troubleshooting PROBLEM: Machine has no power when switched ON. Resolution 1. Check that the scrubber is in “Working Mode”, on Idle side housing. • On the “Idle Side” housing, if the red lever is in the that indicates “Transport Mode”. If the red lever is in the that indicates “Working Mode.
Troubleshooting PROBLEM: Water leaking from bottom of clean water tank. Resolution Base Valve Assembly faulty - Replace Assembly a) Remove Clean Water Tank from handle. b) On bottom side of the handle, remove the solution hose. c) Remove the (2) philips screws. d) Replace base valve assembly.
Troubleshooting PROBLEM: Brushes not spinning, motor hums. Resolution Check for possible faulty Capacitor. Press and twist counter clockwise to release pull cable from Tank Lid Using a flat head screwdriver pry open both sides of Tank Lid to open. Disconnect wires from Capacitor. Discharge Capacitor - (Instructions for discharging and testing capacitor are below).
Troubleshooting Set up the Multi-Meter • Turn the dial on the multi-meter to the setting for capacitance. Most multi-meters use the symbol “ ( “ to signify capacity. You should also see a uF symbol on the display, which stands for Microfarads.
Troubleshooting PROBLEM: Drum not spinning and there is a grinding sound. Resolution – Check for stripped teeth on Drum. A. Using a 5mm allen wrench, remove the (4) allen screws on the drive side cover. B. Using a 5mm allen wrench, loosen the allen screw on the Idler Assembly (Belt Tensioner) and remove the belt.
Work Instructions Replacing Drum or Motor Remove the 3mm allen screw on both sides of the handle, pull the handle away from the Idle and Drive side cover. This may require using a rubber mallet and tapping the handle to free it from the cover. Remove the (4) 5mm allen screws on the Idle Side Cover.
Page 13
Work Instructions Once the electric cover is removed, you will need to use a “small” flathead screwdriver, to loosen and remove the GRN/YLW ground wire from the receptacle. Next, remove the dark BLU wire going into the terminal block. On the opposite side of the terminal block remove the white, black, red (motor wires) and brown wire (dark blue and brown wires are the capacitor wires).
Page 14
Work Instructions 13. Remove the bushing on the handle shaft and slowly pull the housing apart. 14. Pull the drum assembly off carefully. At this point you can remove / replace the drum assembly. Reassemble in reverse order. To remove motor continue below.