Ecosy+ REVOLUTION 21 Technical Information

Ecodesign boiler stove

Advertisement

Quick Links

Version
Last updated
1.2
06/08/2024
REVOLUTION 21
TECHNICAL INFORMATION F O R T H E REVOLUTION 21 ECODESIGN BOILER STOVE
ADDRESS
CONTACT
Ecosy+
Telephone:
+ 44 1256 830099
Unit 24, Folly Farm, Ramsdell
Email:
trade@ecosystoves.co.uk
Tadley, Hampshire
RG26 5RJ
United Kingdom
Brought to you by

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REVOLUTION 21 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ecosy+ REVOLUTION 21

  • Page 1 Version Last updated 06/08/2024 REVOLUTION 21 TECHNICAL INFORMATION F O R T H E REVOLUTION 21 ECODESIGN BOILER STOVE ADDRESS CONTACT Ecosy+ Telephone: + 44 1256 830099 Unit 24, Folly Farm, Ramsdell Email: trade@ecosystoves.co.uk Tadley, Hampshire RG26 5RJ United Kingdom...
  • Page 2: Table Of Contents

    Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 CONTENTS 1. WELCOME ........................................3 2. SAFETY ........................................3 3 TECHNICAL INFORMATION ..................................4 3.1 TECHNICAL DATA ....................................4 3.2 PRODUCT FICHE ....................................
  • Page 3: Welcome

    Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 WELCOME DEAR CUSTOMER, Congratulations and thank you for purchasing an Ecosy+ stove. To top it off, this stove backed up with a 3-year guarantee.
  • Page 4: Technical Information

    Phone: 01256 830099 Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 TECHNICAL DATA REVOLUTION 21 Efficiency (%) Nominal Space Heating Output (kW) Nominal Water Heating Output (kW) CO @ 13% O2 (%) 0.06...
  • Page 5: Item List

    (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 ITEM LIST Please see the below drawing, showing what is included. Check the appliance and accessories for any damage. Please contact the supplier if any of the components are missing or damaged prior to the stove being fitted. If the stove has been fitted with damaging, arranging a re- placement can become difficult.
  • Page 6: Appliance Dimensions

    Phone: 01256 830099 Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 APPLIANCE DIMENSIONS REVOLUTION 21 HEIGHT WIDTH DEPTH Dimensions in mm ecosystoves.co.uk REVOLUTION 21 + 44 1256 830099...
  • Page 7: Material Clearances

    Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 MATERIAL CLEARANCES Combustible Material ( With twin walled flue fitted directly onto the stove ) COMBUSTIBLE MATERIAL Dimensions in mm We suggest a minimum of 50mm to non combustible materials to allow air flow around the fire.
  • Page 8: Installation Requirements

    Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 INSTALLATION REQUIREMENTS INSTALLATION BODY Ecosy+ stoves recommend that this stove be installed by a member of an accredited competent person’s scheme e.g. HETAS. If the installer is not a member of a competent person’s scheme, it is a legal requirement, in the UK, to notify your Local building Control Officer in ad-...
  • Page 9: Air Supply

    (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 AIR SUPPLY Your stove will require a constant air supply and should not be used at the same time and in the same room/space as extractor fans or any device which may draw air supply away from the stove, unless the fire is connected to its direct air feed socket.
  • Page 10: Carbon Monoxide (Co) Alarm

    (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 CARBON MONOXIDE (CO) ALARM In compliance with Building Regulations, a carbon monoxide (CO) alarm must be installed in the room where the stove is located that con- forms to BS EN 50291.
  • Page 11: Wiring Diagram

    (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 WIRING DIAGRAM FOR GENERAL GUIDANCE ONLY All electrical work must be carried out by a competent electrician in accordance with the rules in force and the instructions provided by the circulating pump and heating controls manufacturer.
  • Page 12: Four Tapping System

    Phone: 01256 830099 Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 FOUR TAPPING SYSTEM TWO TAPPING SYSTEM ecosystoves.co.uk REVOLUTION 21 + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 13: Certificate Of Compliance

    (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 CERTIFICATE OF COMPLIANCE After completion of the appliance installation please ensure the form below (specimen) is completed by the installation engineer to comply with the requirements of HETAS and building regulations. The wet and dry side must be signed off at the same time. If evidence is not shown that both the wet and dry sides were completed at the same time, the guarantee may be voided.
  • Page 14: Stove Parts

    Phone: 01256 830099 Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 STOVE PARTS FIRE BRICKS AND LOG GUARD ecosystoves.co.uk REVOLUTION 21 + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 15: Baffle

    Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 BAFFLE WET CONNECTIONS Water connection thread size 1” BSP. Connect the water inlet to the bottom. Connect the water outlet to the top.
  • Page 16: Rear Flue Connection

    Phone: 01256 830099 Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 REAR FLUE CONNECTION ecosystoves.co.uk REVOLUTION 21 + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 17: Defra Setting

    (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 DEFRA SETTING The Revolution has been recommended as suitable for use in smoke control areas when burning seasoned wood logs. Each appliance has been factory fitted with a screw that prevents the full closure of the vent. If you are not in a smoke free zone, this can be removed.
  • Page 18: Controlling The Stove

    CONTROLLING THE STOVE The revolution 21 is fantastically simple to use and has just the one control on the base of the fire. When lighting the stove, ensure this vent is open ( on ) to allow lots of air into the fire. In most cases you will also require the door to be ajar for between 3 and 5 minutes to give the dire a quick burst of oxygen.
  • Page 19: Standard Drawings

    Phone: 01256 830099 Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 STANDARD DRAWINGS ecosystoves.co.uk REVOLUTION 21 + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 20: Check Before Use

    Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 CHECK BEFORE USE • Once the stove has been installed and the flue connected replace all the internal components. •...
  • Page 21: Guarantee

    (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 GUARANTEE WHAT’S COVERED The main body of your stove is guaranteed for 3 years. Installation not carried out by a registered HETAS installer will void the guarantee.
  • Page 22 Unit 22 (Office) and Unit 26 Email: trade@ecosystoves.co.uk (Warehouse), Folly Farm, Kingsclere Website: www.ecosystoves.co.uk Road, Ramsdell, TADLEY, RG26 5GJ REVOLUTION 21 FITTING NEW GLASS Ensure the door is on a soft flat surface before removing the glass. Unscrew the glass clamps.

Table of Contents