Statement of conformity ......................................3 Response ECODESIGN ........................................ 4 Response ECODESIGN ........................................ 4 Product Data Sheet in accordance with Commission Regulation (EU) No 2015/1189 ............... 6 Product Data Sheet in accordance with Commission Regulation (EU) No 2015/1187 ............... 6 1. General information ....................................... 7 2.
Product Data Sheet in accordance with Commission Regulation (EU) No 2015/1189 Model identifier(s): MPM Wood Plus 10 Stoking mode: Manual: the boiler should be operated with a hot water storage tank of a volume of at least 300 litre Condensing boiler: no...
90°C and the operating pressure is 1.5 bar. The required flue gas draught after the boiler is approx. 0.20 mbar. MPM Wood Plus boilers can be used to prepare domestic hot water with the use of a heat exchanger installed in accordance with the PN-EN 12828:2013-05 standard.
4. Fuel The fuel for the MPM Wood Plus boilers is firewood (hardwood logs) with a circumference of approximately 20 cm. The wood recommended by the manufacturer is beech or birch. The wood must be dry and seasoned for at least two years.
6. Technical specifications Table 2. Technical parameters of the MPM Wood Plus Nominal heat output Boiler class (according to EN 303 -5: 2021-09) efficiency/emissions 5 klasa Energy efficiency class Thermal efficiency Heating surface Boiler height Housing width Overall width Length without flue...
Table 3. Basic dimensions of the boiler MPM Wood Plus 1070 Figure 2. Basic dimensions of the boiler MPM Wood Plus 7. Transport The boilers are delivered in an assembled condition on a pallet in foil packaging. It is recommended that the boiler be transported as close as possible to the final installation site in this packaging condition to minimise the possibility of damage to the boiler casing.
Boilers of the MPM Wood Plus type can operate in both open and closed systems. An example of how to install the boiler for central heating and hot water in an open system with forced water circulation is shown in Fig. 3. It is recommended to install a thermostatic valve DBV-1 to drain excess energy in case of overheating of the boiler.
18. Accumulation tank 8.3. General requirements for boiler rooms The room in which the MPM Wood Plus boiler will be installed must meet the requirements of the standard (e.g. PN- 87/B-02411). The basic conditions must be met, i.e: the boiler should be placed as close as possible to the chimney(s) and the entrance door to the boiler room should •...
8.6. Connection of the boiler to the central heating system An example of the MPM Wood Plus boiler connection scheme is shown in Fig. 3 and 4. The boiler should be connected to the heating system with flanged or threaded connections, installed in an open system (PN-91/B-02413) and the hot water system in accordance with PN-76/B-02440.
savings of up to 30%. This is linked to the efficiency of the boilers, which generally achieve the highest efficiencies at nominal output. The purpose of the accumulation tank is to store periodic energy surpluses. Water heated in the boiler flows through the accumulation tank, gradually charging the tank.
Open the boiler firing-up door. The filling door, ash pan door and cleanout cover should be tightly closed. Firing-up in the MPM Wood Plus boiler takes place on the ceramic-iron grate, as close as possible to the inlet / window in the metal partition, initially with crushed pieces of paper to heat the chimney and with fine wood.
NOTE! If the boiler is operated with a central heating water temperature of less than 60°C, tar precipitation from the burnt fuel intensifies and the boiler exchanger and flue pipe become overgrown with tar deposits, creating the risk of soot ignition in the chimney. 9.4.
boiler, switch it off and wait for the time necessary for the temperature of the heat transfer surface to decrease. All operations must be carried out with particular care and may only be carried out by adults. Ensure that no children are in the vicinity when cleaning the boiler.
• keep the boiler room in good order, • when opening the boiler door, do not stand in front of the openings but on the side, • during the winter period, the heating should not be interrupted to prevent the water in the system or parts of it from freezing.
Cast iron grate • Screws • Caps • Hinges • During the guarantee period, the manufacturer shall ensure that the subject of the contract is repaired free of charge within 21 days from the date of notification. If the customer prevents the service technician from repairing the boiler within the agreed period, the customer shall bear the costs of the service technician's travel and work.
Add fuel with a higher calorific value or replace Too low a calorific value of the fuel with fuel with the required parameters Wrong pump settings / flow too high Change pump settings/reduce pump flow Excessively high flue gas temperature of the flue Low boiler efficiency due to high chimney pipe due to too much draught or too much air loss...
WARRANTY CARD In accordance with the conditions stated in the operating instructions, a warranty of 48 months is provided on the tightness of the exchanger (welded connections). Boiler type: Boiler number: Power: Year of production: Packing date: Installation date: Stamp and signature of the manufacturer: Dealer's stamp and signature:...
Page 22
MPM PROJEKT MARCIN NYKIEL Roźwienica 147L Boiler manufacturer 37-565 Roźwienica Ecological woj. podkarpackie...
Need help?
Do you have a question about the Wood Plus 10 kW and is the answer not in the manual?
Questions and answers