Lübeck Range hoods Table of contents I. Notice ..................3 II. Feature .................. 3 III. Safety Warning ..............3 IV. Main Parameters ..............6 V. Installation ................8 VI. Operation ................10 Set up WIFI control ..............10 VII. Maintenance ............... 14 Regular cleaning ..............
Lübeck Range hoods I. Notice 1. Thank you for choosing Der Koch range hoods. Please read the instruction manual carefully before use. 2. The installation work must be undertaken by a qualified and competent worker. 3. The manufacturer disclaims all liability for any damage or injury caused because of not following instructions for installation contained in the following text.
Page 4
Lübeck Range hoods • Clean the cooker hood according to the instruction manual and keep the unit from danger of burning. There is a fire risk if cleaning is not carried out in accordance with the instructions. • WARNING: Before connecting the hood, switch off the electricity supply and check that the supplied voltage and frequency coincide with that indicated on the range hood rating label.
Page 5
Lübeck Range hoods Confirm that room ventilation is appropriate with the local authorities. Make sure the maximum air extraction flow rate for the appliances in the room does not exceed 4 Pa (0.04 m bar). The room must have adequate ventilation if an extractor hood is used simultaneously with appliances that run on gas or other fuels.
Lübeck Range hoods • An all-pole disconnection switch having a contact separation of at least 3 mm in all poles should be connected in fixed wiring. • Regularly check the power plug and power cord for damage. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Page 7
Lübeck Range hoods Parts and description Part Picture Quantity Main body Fixing bracket cover Fixing bracket Top cover Wire locker (2 for spare use) Screw (6 X 40mm) Expansion screw(M6x60mm) Main power cable without plug Fixing wire (1 for spare use) Charcoal filter carbon filter support...
Lübeck Range hoods V. Installation • Before installation, please ensure the area is clean to avoid suction of the remaining bits of broken wood and dust. • It cannot share the same air ventilation tube with other appliance such as gas tube, warmer tube, and hot wind tube. •...
Page 9
Lübeck Range hoods 3) NOTE: The next stage of the installation process MUST be completed by two people. • Fix the 4 steel wires to the fixing bracket using the wire lockers. • Connect the power cable without plug • Adjust the steel wires to a suitable length and check they are equal.
Lübeck Range hoods VI. Operation Off button It’s used for turning off the fan. Low Speed It’s used for Ventilation on the kitchen. It is button suitable for simmering and cooking which do not make much steam. Medium Speed Airflow speed is ideally for ventilation in button standard cooking operation.
Page 11
Lübeck Range hoods Operation of Tuya smart app: 2. Choose “Kitchen Appliances” 1.Click Add device to enter the from the menu and then select manual adding interface “Kitchen Hood”. 3. Choose “Other Mode” 4. Select hot pot distribution network (compatibility mode) www.derkochline.com...
Page 12
Lübeck Range hoods 6. Fill in the current WIFI hot spot you can connect to, and 5. Click the confirmation then click “Confirm” to enter indicator to flash the next step. 8.Click to connect, and then operate the display. Press and hold the light key for dialing, and the dialing process will flash for 2 minutes.
Page 13
Lübeck Range hoods 9. Select “smartlife-6f18”. 8. Click “WLAN” 11.Matching connecting 10.After connecting “smartlife- WiFi module within 1 minute. If 6f18”, click Tuya in the upper the connection is successful, the left corner to return to the app. interface will pop up. www.derkochline.com...
Lübeck Range hoods VII. Maintenance • To protect the main body from corrosion over a long period of time, the range hood should be cleaned with hot water plus non corrosive detergent every two months. • Please do not use abrasive detergent for it will damage the body. •...
Lübeck Range hoods • Clean with a soft cloth/brush. Rinse thoroughly and dry well. • Clean the filter monthly. If the hood is used for more than 2 hours a day, we recommend that you increase the cleaning frequency. • Depending on the hood use frequency, replace the filter in time! Always use genuine filters from the manufacturer.
Lübeck Range hoods 3. Remove the existing carbon filter by gently lifting it upwards and sideways off the power cable. 4. Fit the activated carbon filter by reversing the removal steps. 5. Slide the filter into the center of the power cable and lower onto the filter support, then lower the metal top cover on top.
Lübeck Range hoods VIII. Troubleshooting Fault Cause Solution The fan blade is Light comes jammed. on, but fan Switch off the unit and repair does not by a qualified service agent. The motor is work damaged. Replace the bulb with correct Light bulb burns.
Lübeck Range hoods Warranty Certificate This "Warranty Certificate" is extended for a twelve-month coverage on the equipment detailed below, from the date of purchase and under the conditions stipulated: Our obligation within the terms of this guarantee is to replace, without charge to the Client, any part that, in our opinion, has manufacturing defects.