RUNHOOD F3600 User Manual

Residential ess & portable power station

Advertisement

Quick Links

English
RESIDENTIAL ESS
& PORTABLE POWER STATION
USER MANUAL
IOS
Android
service@runhoodpower.com
www.runhoodpower.com
www.runhoodpower.com
Version: US_2024_04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F3600 and is the answer not in the manual?

Questions and answers

Summary of Contents for RUNHOOD F3600

  • Page 1 English RESIDENTIAL ESS & PORTABLE POWER STATION USER MANUAL Android service@runhoodpower.com www.runhoodpower.com www.runhoodpower.com Version: US_2024_04...
  • Page 2: Table Of Contents

    3.1.2 Residential energy storage and power backup scenarios 3.1.3 Residential on-grid energy storage scenarios 3.2 PRODUCT BREAKDOWN INTRODUCTION 3.2.1 F3600 residential ESS & portable power station 3.2.2 B3600 residential ESS & portable battery 3.3 PORT DEFINITION 3.3.1 F3600 residential ESS & portable power station 3.3.2 B3600 residential ESS &...
  • Page 3: Safety Guidelines

    -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to station (F3600) and B3600 home ESS & portable battery (B3600). RUNHOOD reserves the right to modify and update this manual based on which the receiver is connected.
  • Page 4: Product Features

    2.5 PRODUCT FEATURES 3.1.2 Residential energy storage and power backup scenarios 1. F3600 comes with a 3600W AC off-grid inverter and multiple socket ports. It can serve as a backup UPS when used alone, with an Standardized modular design automatic switching time of less than 10 ms.
  • Page 5: Product Breakdown Introduction

    Anderson DC output port DC 12V/24V AC overcurrent protector Press the AC output switch to turn on or off the AC socket and HOME BACK UP port output of the RUNHOOD F3600, and light up the Anderson output mode switch Grounding screw button indicator light.
  • Page 6: B3600 Residential Ess & Portable Battery

    Figure 3-5 Debugging communication port COM-2 3) In residential power backup mode, it can serve as an AC input port, and the maximum charging power of one set of F3600-US is 1800W. Dry contact communication port 15.HOME BACK UP port...
  • Page 7: Port Definition

    The port (orange) contains wires and communication cables, which have different functions in different scenarios: 1) When F3600 is used for home energy storage applications, this port is connected to the hybrid inverter battery port; 2) During DC parallel operation, this port is connected to the lower connection port of the front-end F3600 or B3600.
  • Page 8 6. The COM-2 debugging port wire sequence is shown in the following figure: The port is orange and has different functions in different application scenarios: 1) Used as the backup charging port (connected to HOME SUB PANEL). 2) Used as the AC expansion discharging port during parallel connection (connected to DOUBLE VOLTAGE HUB). 3) Used as the AC charging port (connected to EV charging adapter).
  • Page 9: B3600 Residential Ess & Portable Battery

    0, automatic encoding will be performed during parallel operation. Encoding bit Encoding Figure 3-16 The port (black) contains wires and communication cables, which is connected to the upper connection port of F3600 or B3600, as defined below: Identification Description...
  • Page 10 6. The dial switch port is shown in the following figure: CAN1H hybrid inverter communication CAN H CAN1L hybrid inverter communication CAN H RS485_A RS485 A RS485_B RS485 B Figure 3-20 Table 3-11 The dial switch has a total of 6 digits. The following are the instructions for the dial switch and its usage. 4.
  • Page 11: Lcd Display Content

    3.4 LCD DISPLAY CONTENT 3.4.1 F3600 residential ESS & portable power station 1. The main interface is shown in the following figure: The language selection interface is shown in the following figure: Status prompt identifications: Include fan operating status, WiFi connection identification, Bluetooth connection...
  • Page 12: Specifications And Parameters

    3. The hybrid inverter mode interface is shown in the following figure: 3.5 SPECIFICATIONS AND PARAMETERS 3.5.1 F3600 residential ESS & portable power station F3600-US Model Device parallel status identification and device code. Net weight 48kg/105.8 lbs.Approx. Input power. Dimensions 58.8cm*40cm*42.4cm/23.1in*15.7in*16.7in...
  • Page 13: B3600 Residential Ess & Portable Battery

    Charging temperature range 4.3.2 QR Code Download 2°C - 50°C Charging temperature range The Android users can search for "runhood" in the Play Store market to download or scan the QR code below for downloading and CAN/RS485 installation. Communication methods...
  • Page 14: Installation And Maintenance

    Optional black/orange plug/wire length RUNHOOD will not be responsible for any losses caused by non-compliance with relevant safety instructions or failure to follow the connection backup function 2000 mm cable installation, maintenance, and use instructions in the manual.
  • Page 15: Usage And Installation Guidelines

    Figure 5-3 5.2.2 Charging 1. By connecting the AC charging cable to the wall socket and the AC input port of F3600, the device will automatically turn on and Cat.6 ethernet charge. It cannot be powered off during the charging process and will automatically stop charging when fully charged. F3600-US...
  • Page 16: Discharging

    3600W for your device. Please refer to 3.5 Specification and parameters for details. 4. As for F3600 AC output support and the use of a vehicle electrical charger, the charger can be used to connect to the F3600 AC socket to recharge the electric vehicle when the electric vehicle's power is depleted.
  • Page 17: Dc Parallel Mode

    The RUNHOOD F3600 and B3600 product supports both "F3600+B3600" and "B3600+B3600" parallel modes. By parallel operation, the total battery capacity of F3600 or B3600 can be expanded, with a maximum capacity of 8 * 3.6KWh. In parallel mode, the power of F3600 is displayed as the total charging/discharging power of the parallel battery system.
  • Page 18 The "Signal connect" in the figure below is the "communication connection board", by which it mainly achieves the AC parallel communication of two sets of F3600. It can be placed in the main distribution box or external junction box.
  • Page 19: Residential On-Grid Energy Storage Mode

    BMS and the inverter for parallel operation is CAN communication, and the SOC notified by the BMS to the inverter is the average SOC. After the battery is successfully connected to the inverter, F3600 can only be charged or discharged via the inverter, and other charging and discharging ports (such as USB output ports) are not available.
  • Page 20 Figure 5-27 side, please use extra battery cable 1.5m. Step 6: Use an Ethernet cable to connect the hybrid inverter communication port of F3600 or B3600, with port identification: COM-1. Figure 5-28 Step 7: Power-on: power on the RUNHOOD F3600 and B3600 product and confirm that the inverter is successfully connected. At this time, the product enters the hybrid inverter mode, and the LCD displays the hybrid inverter mode interface, indicating that the communication with the inverter is successful.
  • Page 21: Maintenance

    Check if the DC parallel port and extra battery cable are connected communication properly, and automatically restore after the connection is correct. If between F3600 and it cannot be restored or cannot be used normally after restoration, other devices please contact a professional.
  • Page 22 Abnormal Disconnect the electrical appliance, and click the USB output switch to Check and restart the device for restoration. If it cannot be restored communication restore. If it cannot be restored or cannot be used normally after USB-C1 port fault between the main or cannot be used normally after restoration, please contact a restoration, please contact a professional.
  • Page 23: Transportation And Storage

    Stop charging and wait for the device to restore or restart the device The output power decreases, and the idle device recovers after Inverter battery to restore. If it cannot be restored or cannot be used normally after 12V radiator cooling down.

Table of Contents