Power Supply Redundancy - Cisco WS-C4507R Troubleshooting Manual

Troubleshooting guide
Hide thumbs Also See for WS-C4507R:
Table of Contents

Advertisement

RST-3508
9805_05_2004_c2
RST-3508
9805_05_2004_c2
© 2004 Cisco Systems, Inc. All rights reserved. Printed in USA.
Presentation_ID.scr

Power Supply Redundancy

cat4500(config)#power redundancy-mode ?
combined
combine power supply outputs (no redundancy)
redundant
either power supply can operate system (redundancy)
© 2004 Cisco Systems, Inc. All rights reserved.
Power Supply Redundancy
cat4507R#show power
Power
Supply
Model No
Type
------
----------------
---------
PS1
PWR-C45-2800AC
AC 2800W
PS2
PWR-C45-1400AC
AC 1400W
*** Power Supplies of different type have been detected***
Power supplies needed by system
Power supplies currently available : 1
*** Insufficient power supplies present for specified configuration ***
Power Summary
(in Watts)
Used
Available
----------------------
----
---------
System Power (12V)
335
Inline Power (-50V)
0
Backplane Power (3.3V)
40
----------------------
----
Total Used
375 (not to exceed Total Maximum Available = 1400)
© 2004 Cisco Systems, Inc. All rights reserved.
Fan
Inline
Status
Sensor
Status
-----------
-------
-------
bad/off
bad/off
bad/off
good
good
n.a.
: 2
Maximum
1360
0
40
19
19
19
20
20
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 4000Catalyst 4500

Table of Contents