Summary of Contents for Carrier Tyler Advantage NFJCX
Page 1
Installation & Service Manual NFJCX, NCJCX, NTJCX, NFMJCX, NFJECX, NCJECX JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General (UL/NSF) Installation & Service Manual. Save the Instructions in Both Manuals for Future Reference!! This merchandiser conforms to the American National Standard Institute &...
NFJCX, NCJCX, NTJCX, Installation & Service Manual NFMJCX, NFJECX, NCJECX INSTALLATION PROCEDURES After all case pull-ups have been secured, all interior wall joint seams should be sealed with Carpentry Procedures duct tape. Plexiglas Partition A plexiglas plug partition is required on adja- cent electric defrost cases that are on differ- ent defrost schedules.
Page 8
NFJCX, NCJCX, NTJCX, NFMJCX, NFJECX, NCJECX and one for the shelf lights. The sockets NOTE are not interchangeable. The anti-sweat Items 8 and 9 will be shipped loose on harness male plug connects at the RH superstructures ordered through TYLER post socket.
NFJCX, NCJCX, NTJCX, Installation & Service Manual NFMJCX, NFJECX, NCJECX 8. Install shelving close-offs (19) in space Trim Installation/Alignment between shelves. The close-offs are See “General-UL/NSF I&S Manual” for supported by the shelf brackets (16). If bumper, color band, raceway and kickplate end close-offs (20) are supplied, they are installation.
NFJCX, NCJCX, NTJCX, NFMJCX, NFJECX, NCJECX Refrigeration Procedures to easily switch from medium to low tempera- ture operation by flipping a switch. The dual See “General-UL/NSF I&S Manual” for temperature control consists of an EPR valve general system, control and superheat in the suction line coming off the evaporator.
NFJCX, NCJCX, NTJCX, Installation & Service Manual NFMJCX, NFJECX, NCJECX Electrical Procedures Defrost Information See “General-UL/NSF I&S Manual” for Electrical Considerations operational descriptions for each type CAUTION of defrost control. Make sure all electrical connections at Defrost Control Chart components and terminal blocks are tight. Defrost This prevents burning of electrical terminals Defrost...
NFJCX, NCJCX, NTJCX, NFMJCX, NFJECX, NCJECX Defrost Schedules NOTE Insulated partitions must be used between For satisfactory performance, both sides of case line-ups that have gas defrost! the case should be scheduled to defrost at the same time. This holds true even when Gas defrost cases (NFJCX/NCJCX/NFJECX/ both sides run from different machines.
NFJCX, NCJCX, NTJCX, NFMJCX, NFJECX, NCJECX CLEANING AND SANITATION Discharge Air Duct Panels Component Removal and 1. Remove bottom trays and discharge air Installation Instructions for honeycomb, see above. Cleaning 2. Remove mounting screws and discharge air duct panels from both sides of the Bottom Screens and Trays center riser (NFJCX/NCJCX/NTJCX/ 1.
NFJCX, NCJCX, NTJCX, Installation & Service Manual NFMJCX, NFJECX, NCJECX SERVICE INSTRUCTIONS 3. Remove four screws (4) and corner See “General-UL/NSF I&S Manual” for fan cladding trim (5) blade and motor replacement, color band 4. Remove two top screws (6) from the and bumper replacement and raceway raceway corner trim (7), then lift and cover removal instructions.
NFJCX, NCJCX, NTJCX, NFMJCX, NFJECX, NCJECX Center Riser Discharge Air Anti-Sweat Drain Pan Heater Replacement (NFJCX/NCJCX/NTJCX/NFMJCX) WARNING Always shut off electricity to case before replacing a drain pan heater. Automatic cycling of fans or electrical power to wire ends could cause personal injury and/or death.
NFJCX, NCJCX, NTJCX, Installation & Service Manual NFMJCX, NFJECX, NCJECX Return Air Duct Anti-Sweat Return Air Duct Anti-Sweat (NFJCX/NCJCX/NTJCX/NFMJCX) (NFJECX/NCJECX) NOTE NOTE Cladding joint trim, raceway cover, Cladding corner trim, bumper corner trim, cladding, bumper and front and bumper front bumper and front bumper retainer retainer must be removed from front must be removed from the end case.
NFJCX, NCJCX, NTJCX, NFMJCX, NFJECX, NCJECX PARTS INFORMATION Cladding and Trim Parts Lists Item Description NFJCX/NCJCX/NTJCX/NFMJCX 8’ 12’ Bumper Retainer color per order Bumper Retainer/Hand Rail Backer 9025316 (2) 9025316 (2) Color Band, Painted 9023798 (2) 9023800 (2) Color Band Backer, Ptd. 9040223 (2) 9040223 (2) Bumper End Trim...
Page 30
NFJCX, NCJCX, NTJCX, NFMJCX, NFJECX, NCJECX Item Description NFJECX/NCJECX Front Side Bumper Retainer color per order Bumper Retainer/Hand Rail Backer 9025316 9025316 Color Band, Painted 9023795 9023789 Color Band Backer, Ptd. 9040223 9040223 Bumper End Trim color per order Bumper Backer color per order Bumper color per order...
NFJCX, NCJCX, NTJCX, NFMJCX, NFJECX, NCJECX Operational Parts List Case Usage Domestic Export Electrical Circuit 115 Volt 60 Hertz 220 Volt 50 Hertz Case Size 8’ 12’ End Case 8’ 12’ End Case Fan Motor 5644521 5644521 5644521 5126572 5126572 5126572 5 Watt 5 Watt...
Need help?
Do you have a question about the Tyler Advantage NFJCX and is the answer not in the manual?
Questions and answers