Download Print this page

Fishing Mode - Casio 4732 Operation Manual

Advertisement

Operation Guide 4732 4733
Home Site Data
Moon phase, the fishing level indicator, and Fishing Mode data will not be
displayed properly unless Home Site data (UTC differential and longitude) is
configured correctly.
• The UTC differential is a value that indicates the time difference between a
reference point in Greenwich, England and the time zone where a city is located.
• The letters UTC is the abbreviation for Coordinated Universal Time, which is the
world-wide scientific standard of timekeeping. It is based upon carefully maintained
atomic (cesium) clocks that keep time accurately to within microseconds. Leap
seconds are added or subtracted as necessary to keep UTC in sync with the Earth's
rotation.
• The "Site Data List" provides UTC differential and longitude information around the
world.
• The following is the initial factory default Home Site data (Tokyo, Japan) when you
first purchase the watch and whenever you have the batteries replaced. Change
these settings to match the area where you normally use the watch.
UTC differential (+9.0); Longitude (East 140 degrees)
To configure Home Site data
1. In the Timekeeping Mode, hold down A until the
Longitude
seconds start to flash, which indicates the setting
(east/west)
screen.
2. Press C twice to display the UTC differential setting
screen, and confirm that the setting is correct.
• If the UTC differential setting is not correct, use D (+)
and B (–) to change it.
3. Press A to display the longitude value setting screen.
4. Press C to toggle the flashing between the longitude
value and the longitude unit (east/west).
5. While the setting you want to change is flashing, use
Longitude
D and B to change it as described below.
value
Setting
Screen
Use D (+) and B (–) to change the setting.
Longitude Value
• You can specify a value from 0° to 180°, in 1-
degree units.
Use D to switch between east longitude ( )
Longitude Unit
(East/West)
and west longitude (
6. Press A to exit the setting screen.
Setting the Analog Time
Perform the procedure below when the time indicated by the analog hands does not
match the time of the digital display.
To adjust the analog time
1. In the Timekeeping Mode, press C seven times to
enter the Hand Setting Mode.
2. Hold down A until the current digital time starts to
flash, which indicates the setting screen.
3. Use D to adjust the analog setting.
• Press D once to advance the hands 20 seconds.
• Hold down D to advance the hands at high speed.
• To lock high speed hands movement, hold down D to start it and then press B
to lock. The hands will continue to advance for one 12-hour cycle or until you
press any button to stop it.
It will also stop automatically after the time advances 12 hours or if an alarm (daily
alarm, Hourly Time Signal, or countdown beeper) starts to sound.
4. Press A to exit the setting screen.
• The minute hand will be adjusted slightly to match the seconds when you exit the
setting screen.
• To return to the Timekeeping Mode, press C.

Fishing Mode

The Fishing Mode displays an indicator that shows, as
Moon phase
Month – Day
one of five levels, the suitability of a specific date and time
indicator
(minute 00 to minute 59 of a particular hour) for fishing.
This mode also can be used to display Moon Data (Moon
age and Moon phase) for a specific date.
• If you suspect that the fishing level indicator or current
Moon data is wrong for some reason, check the current
Timekeeping Mode settings (time, date, and Home Site),
and correct them if required.
• See "Moon Phase Indicator" for information about the
Time
Moon phase indicator.
Fishing level
• All of the operations in this section are performed in the
indicator
FISH
Fishing Mode, which you enter by pressing C.
indicator
Fishing Level Screen
Fishing Level Indicator
The fishing level indicator shows the relative favorability of a fishing time (calculated in
accordance with Moon transit and phase) as shown in the table below.
Module
Level 5
Level 4
4732
4733
Moon Transit
Upper
Moon Phase
Lower
New moon*
Level 5
Full moon
First quarter
Level 4
Last quarter
Other
Level 3
* These indicators actually appear during Moon ages 13.0 to 16.6 (Full Moon and
phase immediately preceding it) and 27.7 to 1.8 (New Moon and phase immediately
preceding it).
Button Operations
).
Level 3
Level 2
Level 1
West
Other
East
Level 4
Level 3
Level 3
Level 2
Level 2
Level 1
• The fishing level indicator changes in accordance with the Moon data.
• In the Timekeeping Mode, the FISH indicator flashes whenever the fishing level of
the current time is 4 or 5.
To view the current fishing level and Moon data
In the Fishing Mode, press A to toggle between the fishing level screen and the
Moon Data screen.
• The fishing level indicator shows the level for the displayed time. The initial fishing
level screen shows the level for 6:00 a.m. The Moon data screen shows the Moon
age and Moon phase for the current date.
Fishing Level Screen
Month – Day
Press A.
Fishing level
indicator
Time
• While the fishing level screen is displayed, press D to advance to the next hour.
• While the Moon Data screen is displayed, press D to advance to the next day.
• You can also specify a particular date (year, month, day) to view its fishing level and
Moon data. See "To specify a date" for more information.
• When you enter the Fishing Mode, the screen (fishing level or Moon data) that was
displayed the last time you exited the mode appears first.
To specify a date
1. In the Fishing Mode, hold down A until the year setting
Month – Day
starts to flash, which indicates the setting screen.
2. Press C to move the flashing in the sequence shown
below to select the other settings.
Year
Year
3. While a setting is flashing, use D (+) or B (–) to change it.
• You can specify a date in the range of January 1, 2000 to December 31, 2099.
4. Press A to exit the setting screen.
5. Use A to display either the fishing level screen or the Moon Data screen.
Thermometer
This watch uses a temperature sensor to measure temperature. A reading is taken
during each even-numbered minute, and the result of the last reading is displayed on
the thermometer screen.
The watch also takes separate readings and stores them in memory for display in the
temperature tendency graph, which can be viewed in the Timekeeping Mode.
Measured temperature values are stored in memory for later recall when you need
them.
Thermometer Screen
Temperature
Press A.
• You can select either Celsius (°C) or Fahrenheit (°F) units for the thermometer
screen. See "To specify the temperature display unit" for more information.
• The thermometer screen displays temperature values in 0.1°C units (or 0.2°F units).
• The display range of the thermometer screen is –10.0°C to 60.0°C (or 14.0°F to
140.0°F).
• You can calibrate the temperature sensor if you feel that the displayed temperature
values are not correct. See "Temperature Sensor Calibration" for more information.
Important!
• Temperature measurements are affected by your body temperature (while you are
wearing the watch), direct sunlight, and moisture. To achieve a more accurate
temperature measurement, remove the watch from your wrist, place it in a well
ventilated location out of direct sunlight, and wipe all moisture from the case. It takes
approximately 20 to 30 minutes for the case of the watch to reach the actual
surrounding temperature.
Temperature Tendency Graph
The watch also takes temperature readings at the top and the bottom of each hour
and stores the results in memory for display on the temperature tendency graph.
Depending on the current Timekeeping Mode time, the temperature tendency graph
shows either the top of the hour measurements or the bottom of the hour
measurements for the past 17 hours.
From the top of each hour to the 29th minute, past top of the hour readings are shown
in the graph. From the bottom of each hour to the 59th minute, past bottom of the hour
readings are shown in the graph.
Temperature tendency graph contents are updated every 30 minutes.
Past 17 hours of
Latest measurement
measurement values
value
Moon Data Screen
Moon phase
Month – Day
indicator
Moon age
Month
Day
Temperature
Tendency Screen
Temperature
tendency
graph
+6.0 to +9.9°C (+10.8 to +17.8°F)
+2.0 to +5.9°C (+3.6 to +10.6°F)
–1.9 to +1.9°C (–3.4 to +3.4°F)
–5.9 to –2.0°C (–10.6 to –3.6°F)
–9.9 to –6.0°C (–17.8 to –10.8°F)
2

Hide quick links:

Advertisement

loading

This manual is also suitable for:

4733