Klaxon PSC-0045 Installation Instructions Manual

Sonos dc sounder-beacon

Advertisement

DE
EN
T T O O N N E E T T Y Y P P E E
T T O O N N E E
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
Texecom Ltd (Incorporating Klaxon Signals)
St Crispin Way, Haslingden, BB4 4PW, UK
+44 1706 233879
Installation Instructions
NL
FR
T T O O N N E E D D E E S S C C R R I I P P T T I I O O N N / / A A P P P P L L I I C C A A T T I I O O N N
970Hz
800Hz/970Hz @ 2Hz
800Hz – 970Hz @ 1Hz
970Hz 1s OFF/1s ON
970Hz, 0.5s/ 630Hz, 0.5s
554Hz, 0.1s/ 440Hz, 0.4s (AFNOR NF S 32 001 )
500 – 1200Hz, 3.5s/ 0.5s OFF (NEN 2575:2000 Dutch Slow Whoop)
420Hz 0.625s ON/0.625s OFF (Australia AS1670 Alert tone)
1000-2500Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF ( AS1670 Evacuation)
550Hz/440Hz @ 0.5Hz
970Hz, 0.5s ON/0.5s OFF x 3/ 1.5s OFF (ISO 8201 )
2850Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201)
1200Hz – 500Hz @ 1Hz (DIN 33 404)
400Hz
550Hz, 0.7s/1000Hz, 0.33s
1500Hz – 2700Hz @ 3Hz
750Hz
2400Hz
660Hz
660Hz 1.8s ON/1.8s OFF
660Hz 0.15s ON/0.15s OFF
510Hz, 0.25s/ 610Hz, 0.25s
800/1000Hz 0.5s each (1Hz)
250Hz – 1200Hz @ 12Hz
500Hz – 1200Hz @ 0.33Hz
2400Hz – 2900Hz @ 9Hz
2400Hz – 2900Hz @ 3Hz
500 – 1200Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF ( AS1670 Evacuation)
800Hz – 970Hz @ 9Hz
800Hz – 970Hz @ 3Hz
800Hz, 0.25s ON/1s OFF
500Hz – 1200Hz, 3.75s/0.25s OFF (AS2220)
Fig. 1
+44 1706 223450
ES
PT
EN54-3:2001+A1+A2
Technical Data Document 18-186215
Fire Alarm Device - Sounder
Type A: For indoor use (Shallow Base)
Type B: For outdoor use (Deep Base)
PSS-0068/73/79/80 & PSC-0055: 0832-CPD-0297
PSC-0045/54/62/63/51
sales@klaxonsignals.com www.klaxonsignals.com
@
Sonos DC Sounder-Beacon
IT
PL
D D I I P P S S W W I I T T C C H H
d d B B A A @ @ 1 1 m m
O - O - O - O - O
O - O - O - O - I
O - O - O - I - O
O - O - O - I - I
O - O - I - O - O
O - O - I - O - I
O - O - I - I - O
O - O - I - I - I
O - I - O - O - O
O - I - O - O - I
O - I - O - I - O
O - I - O - I - I
O - I - I - O - O
O - I - I - O - I
O - I - I - I - O
O - I - I - I - I
I - O - O - O - O
I - O - O - O - I
I - O - O - I - O
I - O - O - I - I
I - O - I - O - O
I - O - I - O - I
I - O - I - I - O
I - O - I - I - I
I - I - O - O - O
I - I - O - O - I
I - I - O - I - O
I - I - O - I - I
I - I - I - O - O
I - I - I - O - I
I - I - I - I - O
I - I - I - I - I
: 0832-CPD-0546
Issue 13 (Feb 2011) INS532-13
Copyright © Texecom Ltd
SE
DK
m m A A
99
21
20
100
20
100
14
99
19
99
13
97
16
99
9
96
14
104
14
97
12
98
94
21
99
17
95
13
98
17
34
104
18
99
45
106
17
96
12
96
11
96
15
98
21
100
13
98
17
99
101
40
104
40
98
10
20
99
20
100
8
99
17
99
0832
06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSC-0045 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Klaxon PSC-0045

  • Page 1 Type B: For outdoor use (Deep Base) PSS-0068/73/79/80 & PSC-0055: 0832-CPD-0297 PSC-0045/54/62/63/51 : 0832-CPD-0546 Issue 13 (Feb 2011) INS532-13 Texecom Ltd (Incorporating Klaxon Signals) Copyright © Texecom Ltd St Crispin Way, Haslingden, BB4 4PW, UK sales@klaxonsignals.com www.klaxonsignals.com +44 1706 233879...
  • Page 2 Installation Manual Installationsanweisung Installation Installation If required, the mechanism for locking the sounder to the base Um den Signalgeber im Sockel zu arretieren, ist das can be activated by removing the thin section of plastic shown in Sicherungsplättchen im Gehäuse zu entfernen. Dies kann vorsichtig Fig.
  • Page 3: Notice D'instructions

    Notice d'instructions Montageinstructies Montage Certification NF Seules les modèles avec une des références commerciales ndien nodig kan het mechanisme om het alarm aan de basis te suivantes sur leur tête et ayant l’estampille NF sont certifiées NF: vergrendelen worden geactiveerd door het verwijderen van het dunne stukje plastic met een tang of vergelijkbaar gereedschap i i d d e e n n t t i i f f i i c c a a t t i i o o n n Référence commerciale Description zoals aangegeven in Fig.
  • Page 4: Instrucciones De Instalación

    Instrucciones de Instalación Manual de Instalação Instalación Instalação Active el mecanismo de seguridad si esto fuera necesario, para Se necessário, o mecanismo para fixar o sensor à base pode ser evitar que la sirena pueda ser desconectada de la base. Para activado removendo a fina película de plástico ilustrada na Fig.
  • Page 5: Istruzioni Di Installazione

    Instrukcja montażu Istruzioni di installazione Installazione Instalacja W razie potrzeby mechanizm blokujący głośnik na podstawie Se necessario, è possibile attivare il meccanismo di bloccaggio del można uruchomić, usuwając cienką warstwę folii pokazaną na segnalatore acustico alla base rimuovendo la sottile linguetta di plastica illustrata nella Fig.
  • Page 6 Installationsmanual Installationsanvisninger Installation Installation Om så behövs, kan mekanismen för att låsa summern vid basen Om nødvendigt kan mekanismen for aflåsning af lyd alarmen til aktiveras genom att avlägsna den tunna plastbiten, såsom visas underlaget aktiveres ved at fjerne det tynde plastik lag, som vist i Fig.

This manual is also suitable for:

Pss-0073Pss-0079Pss-0080Psc-0055Psc-0002Pss-0068 ... Show all

Table of Contents