Page 1
LoRa Sensor Terminal FST200 User Manual V1.0.0 This manual is applicable to the following products: FST200-00HA, FST200-00HC, FST200-00HC, FST200-00LC Xiamen Four-Faith Communication Technology Co., Ltd. https://www.fourfaith.com...
FST200 LoRa Sensor Terminal User Manual Document Revision History Date Version Note Author 2022-10-27 V1.0.0 Initial Version Jonas...
Page 3
FST200 LoRa Sensor Terminal User Manual Note: There may be differences between models of accessories and interfaces, actual products shall prevail.
All contents in the files are protected by copyright law, and all copyrights are reserved by Xiamen Four-Faith Communication Technology Co., Ltd. Without written permission, all commercial use of the files from Four-Faith are forbidden, such as copy, distribute, reproduce the files, etc., but non-commercial purpose, downloaded or printed by individual (all files shall be not revised, and the copyright and other proprietorship notice shall be reserved) are welcome.
Page 5
FST200 LoRa Sensor Terminal User Manual NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user’s authority to operate the equipment.
The product adopts a variety of configuration modes to facilitate rapid and flexible deployment. It can also be combined with the Four-Faith sensor cloud platform and APP to realize remote real-time data monitoring.
Battery power supply (FST200-00HA): Adopted by Four-Faith LoRa module, ultra- low power design, built-in 19000mA ultra-large capacity lithium sub-battery DC power supply (FST200-00HC): Supports 5 to 36V, 12V/0.5A by default Shell: ABS+PC, anti-UV, flame retardant materials and other exquisite integrated appearance design.
FST200-00HA: -20~+60℃(-4~+140℉) Operating Temperature FST200-00HC :-35~+75℃(-31~+167℉) FST200-00HA: Built-in 3.6V/19000mAh lithium battery (Disposable) Power Supply FST200-00HC: Supplies power from the DC power adapter. The default value Method is 12V/1.5A ≤10.5mA, (SF=9@20dBm) Receiving Current Note: FST200-00HA/FST200-00HC, FST200-00HA low-power consumption product, FST200- 00HC normal power consumption product; * means under development...
Page 11
FST200 LoRa Sensor Terminal User Manual Interfaces Content Description RS232 Input RS232 Output Ground RS485 Native RS485 Positive Digital signal input and output (0-3.3V) Digital signal input and output (0-3.3V) Current acquisition analog signal input (0-20mA), maximum 5V input Voltage acquisition analog signal input (0-5V) Output DC is 3.3V and the maximum...
FST200 LoRa Sensor Terminal User Manual 2.2 Appearance ① Bottom: FST200-00HA, battery-power version with one PG9-8 cable waterproof connector ② Bottom: FST200-00HC, DC power version with two PG9-8 cable waterproof connector ③ Front side: NFC induction zone ④ ⑤ ⑥ Rear side:...
FST200 LoRa Sensor Terminal User Manual 2.4 Button Instruction Function Operation LED Status Device Status Off ➡ Green light Long press ACT button Power on activated over 3 seconds flashing Green light Long press ACT button Power off not activated flashing ➡...
Page 15
FST200 LoRa Sensor Terminal User Manual mounting bracket 5. Attach the sensor terminal to the wall mounting mount Pole-mounted installation: Fix the 2 screws on the sensor terminal through the hoop support Unscrew the lock of the hoop counterclockwise...
APP NFC configuration, except for the configuration procedure. Note: The Four-Faith sensor cloud platform described in Chapter 4 can also be configured with the following parameters. For details, refer to the instruction manual of the Four-Faith sensor cloud Figure 3.1 Sensor Could APP...
FST200 LoRa Sensor Terminal User Manual Figure 3.2 Sensor Could APP 3.2 Configuration Steps 1. Download and install PC configuration tools corresponding to FST200-00 series and Android APP from Four-Faith official website. 2. Connect and loading Sensor Terminal Tool Use type-C to connect the computer to the device.
3.3 LoRa Configuration FST200-00 series devices support LoRaWAN configuration * and LoRa private configuration (Four-Faith private protocol). The PC configuration tool and sensor cloud APP are used to automatically distinguish the protocol types supported by the device.
Page 19
FST200 LoRa Sensor Terminal User Manual Open the "NFC Configuration --> LoRa Private Configuration" menu in the Sensor Cloud APP, and set the network mode, network number, device ID, pass-through address, carrier frequency, data rate, and transmit power of the device.
Page 20
2. In the add network mode, modify the carrier frequency, and data rate, and restore factory Settings to execute the network request again. 3. If a large amount of equipment is to be purchased, please contact Four-Faith to obtain FFUI/EUI and other parameters of the equipment.
FST200 LoRa Sensor Terminal User Manual 3.4 Basic Setting Open the "NFC Configuration > Sensing Configuration" menu in the Sensor Cloud APP, set the common device parameters, calibrate the device, and set the threshold. General Parameters Parameter Description Factory Default Value The value ranges from 1 to 65535 minutes.
Page 22
Instruction start data collection. Note: Four-Faith sense cloud platform, such as using the management FST200-00 series equipment, please use the deep sleep mode, regular sleep mode, the gateway leading code time should be the same as the device sleep time www.fourfaith.com...
Page 23
FST200 LoRa Sensor Terminal User Manual Edge Acquisition Parameter Description Factory Default Value FST200-00HA (battery power supply): default Output 3.3V 3.3V output switch FST200-00HC (DC power supply): on FST200-00HA (battery power supply): default Output 12V 12V output switch FST200-00HC (DC...
FST200 LoRa Sensor Terminal User Manual reported). When the 485 acquisition is enabled, Time-out Period abnormal timeout of Modbus command 200ms execution. When the 485 acquisition is enabled, multiple modbus commands are Data Merge executed, and the data merging switch is returned.
1,2 3.6 Maintenance Upgrade FST200-00 series support NFC upgrade of sensor cloud APP, remote upgrade of Four- Faith sensor cloud platform, and PC configuration tool upgrade. The detailed steps are as follows: 1. To obtain the latest software upgrade package from the official website of Four-Faith,...
Page 26
Backup (Batch configuration) The FST200-00 series supports backing up device configuration information and importing it to other devices for quick batch configuration. The backup information does not include LORA-related parameters and is applicable to batch configuration of products of the same series.
Four-Faith Sensor Cloud User Manual.) Gateway Name User defined Gateway Mac Obtain the LAN MAC address from the gateway 5. Wait for the heartbeat interval (1min by default). The Four-Faith sensor cloud platform displays that the gateway is online. www.fourfaith.com Copyright @ Four-Faith 2022...
Page 28
FST200 LoRa Sensor Terminal User Manual Add Device 1. Add the device through the Four-Faith sensor cloud platform, and the device displays the inactive state (or scan the QR code of the device through the sensor cloud APP for quick input).
FST200 LoRa Sensor Terminal User Manual Chapter 5 Data Communication Protocol The FST200-00 series supports the LoRaWAN* protocol and the Four-Faith private protocol. 5.1 Four-Faith Private Protocol For details, please check the "FST200-00 Series API Command Manual". 1. Common format of the data frame (data are based on hexadecimal format, little endian mode).
Page 30
FST200 LoRa Sensor Terminal User Manual The device wakes up for detection. If the device is abnormal, it reports the alarm immediately. Abnormal status: 1 Device abnormal 0x04 Temperature (2), Humidity (2), 2 The measured value is Device Status Abnormal status (1), Warning status...
Need help?
Do you have a question about the FST200 and is the answer not in the manual?
Questions and answers