Download Print this page
Qlight Wall Mount Type Series Manual

Qlight Wall Mount Type Series Manual

Wall mount semicircular led signal towers

Advertisement

Quick Links

Wall Mount Semicircular LED Signal Towers
MWTL
90dB
30
50
55
Thank you for purchasing Qlight's products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to fire, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, fire, electric shock and loss of life.)
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product's specification.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Ordering Specifications
MWTL
-
4
-
[Model
[Layer]
number]
|
|
• MWTL
• 4-4Layer
• 24-DC24V
• MWTLF
• MWTL-BZ
• MWTLF-BZ
Please scan the QR code for more
detailed product information.
www.qlight.com
24
- RAGB
[Voltage]
[Color]
|
|
R-Red
A-Amber
G-Green
B-Blue
Product Specifications
Model number
Layer
MWTL
Steady
MWTL-BZ
Steady /w built-in buzzer
4
MWTLF
Steady/Flashing
MWTLF-BZ
Steady/Flashing/
w built-in buzzer
※ CE compliant : DC24V
• Built-in buzzer : Max.90dB at 1m
• Protection rating : IP55
• Ambient operating temperature : -30°C to +50°C
■ Light source/buzzer current(based on 1 layer)
Voltage
Light source current(1 layer)
Buzzer current
1
Voltage
Certificate Weight
R-Red
A-Amber
DC24V
0.29kg
G-Green
B-Blue
DC24V
55mA
60mA
Color

Advertisement

loading
Need help?

Need help?

Do you have a question about the Wall Mount Type Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Qlight Wall Mount Type Series

  • Page 1 3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to follow these instructions may lead to fire, electric shock, or product damage.) 4.
  • Page 2 Dimensions (Units : mm) MWTL Ø11 CABLE ENTRY 4-Ø4.2 HOLES R43.4 Wiring Instructions • can be wired with either external contact or transistor. MWTL • When using a transistor, please choose between the NPN transistor or PNP transistor which best matches the voltage and product type, then connect them correctly according to the wiring diagram below.
  • Page 3 • In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside- down positions where water can potentially penetrate into the product and impact it’s operation. • For further information, please visit our website (www.qlight.com).
  • Page 4 Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111) Qlight Overseas Sales Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100 Qlight Public Relations & Marketing Team Office | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017 SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | qlightcn@qlight.com China Factory/ Shanghai Sales Office | #Room 333 Building B, #11, Lane 450, Zhenda Road, Baoshan District, Shanghai, China Tel.

This manual is also suitable for:

MwtlMwtl-bzMwtlfMwtlf-bz