WC11PS Series Restroom Control
INSTALLATION INSTRUCTIONS
1. GENERAL DESCRIPTION
The CX-WC11PS Restroom Control Kit allows access in and out of
a restroom with the ability to secure the door once inside. The Kit
also provides annunciation by including an Occupied light. The
designation of "PS" in the part number reflects that this kit now
comes pre-wired in a metal enclosure with a power supply which
is ready to accept all field wiring.
The CX-WC11PS Restroom Control Kit is controlled by Camden's
advanced relay logic controller part numbered as the CX-33.
The CX-WC11PS has two modes. One is Mode 7 for a normally
unlocked restroom and the other is Mode 8 for a normally locked
restroom. In Mode 7 when the exterior PUSH to OPEN button
is pressed it will trigger the door operator to open the door. In
Mode 8 when the exterior PUSH to OPEN button is pressed it will
unlock the strike and trigger the door operator to open the door.
Once in the restroom and the PUSH to LOCK button is pressed it
will keep the door locked in either mode and disable the exterior
PUSH to OPEN button, as well as, providing annunciation with an
Occupied light. When exiting the restroom, you can either press
the inside PUSH to OPEN button to unlock the door and open the
door or you can push the crash bar, paddle or turn the knobset
to break the door contact circuit which will also unlock the door
and reset the system. The Occupied light will turn off signaling
the restroom is available.
2. INSTALLATION
Operation at a Glance
When the exterior PUSH TO OPEN button is pressed it will send
a momentary closure to the outside PUSH TO OPEN terminal
on the CX-WC11PS allowing the door to swing open. When
the interior PUSH TO LOCK button is pressed it will send a
momentary closure to the to inside PUSH TO LOCK terminal
on the CX-WC11PS causing it to lock the restroom and turn on
the Occupied light. When the inside PUSH TO OPEN button is
pressed it will send a momentary closure to the inside PUSH TO
OPEN terminal on the CX-WC11PS causing it to unlock the door
and open it. The Occupied light will now turn off signalling the
restroom is now vacant. The restroom can also be unlocked by
opening the door from the inside which will break the door contact
circuit causing the CX-WC11PS to reset and unlock the door.
Page 1 of 9
Mounting
IMPORTANT: Do not apply power to the unit until you have fully
read the instructions and have made the required adjustments.
The CX-WC11PS cabinet should be mounted in a clean dry
location out of direct contact with the elements.
Wiring the CX-WC11PS Series Restroom
Control Kit is as follows:
The CX-WC11PS comes from Camden with the CX-33 pre-wired
to a labeled set of two terminal strips. This will make the wiring
of the push buttons easier since the wiring manual will no
longer need to be directly referenced for termination points. A
complete wiring diagram is adhered to the inside of the door
to provide a layout of the wiring as a reference when wiring the
field devices to the kit.
There are two terminal strips that mirror the locations on the
CX-33. The left strip is used for power to the CX-33, the PUSH
TO OPEN and PUSH TO LOCK buttons, the door position switch,
and the Wet trigger. The right strip is for the outputs to drive the
strike (Relay 1), door operator (Relay 2), Occupied light (Relay3),
and to provide VDC power for the door strike.
Once all field devices are wired to the CX-WC11PS then AC
power can be wired in.
IMPORTANT: Confirm the electrical panels breaker you are
going to be using is currently off. Do not wire the primary
terminals of the transformer until the secondary terminals
are connected first.
The supplied CX-TRX-5024 transformer will have its secondary
terminals wired to the terminals on the top of the left terminal
strip marked as "AC". Next, wire the primary terminals to the AC
feed to be used. Confirm your connections and apply power by
turning on the electrical panels breaker.
Selecting a Mode
The CX-WC11PS has two restroom applications built in (Mode
7 & 8). The default mode for the CX-WC11PS is Mode 7
(normally unlocked).
Determining which mode is correct for you will be based on
whether the restroom will be normally unlocked (Mode 7) or
normally locked (Mode 8).

Advertisement

loading
Need help?

Need help?

Do you have a question about the WC11PS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CAMDEN WC11PS Series

  • Page 1 Control Kit is as follows: is ready to accept all field wiring. The CX-WC11PS Restroom Control Kit is controlled by Camden’s The CX-WC11PS comes from Camden with the CX-33 pre-wired advanced relay logic controller part numbered as the CX-33.
  • Page 2 “1” will be displayed. Reconnect your power and press the “MENU” button once then Camden builds in typical times for lock release and door use the “UP” or “DOWN” button to advance to the desired mode.
  • Page 3 WC11PS SERIES RESTROOM CONTROL I NSTA LLAT I O N I N S T RU C T I O N S CM-45/4 Active Switch CM-45 MOUNT INSTALLATION Surface Mount Installation Flush Mount Installation 1. Position the back box (CM-43CBL) 1. With the back box already roughed-in,...
  • Page 4: Installation

    WC11PS SERIES RESTROOM CONTROL CX-ED2079 ‘Universal’ Electric Strike IN S TALL AT ION INSTRUCTIO NS 4. Installation CX-ED2079 'UNIVERSAL' ELECTRIC STRIKE INSTALLATION 1. Prepare the door jamb as per the appropriate drawing. 4. Connect wires coming from the low voltage side of the transformer to wires (black) from strike.
  • Page 5: Ordering Information For Replacement Parts

    WC11PS SERIES RESTROOM CONTROL I NSTA LLAT I O N I N S T RU C T I O N S CONNECTIONS OPERATIONS POWER How to modify fail-safe to fail-secure or vice versa. 12VDC 24VDC 1. Loosen the screw as per the product diagram below.
  • Page 6 WC11PS SERIES RESTROOM CONTROL IN S TALL AT ION INSTRUCTIO NS Notes : Questions? Call us toll-free at 1-877-226-3369 or technical support 905-366-3377 (ext. 505) File: WC11PS Restroom Controls Opening New Doors to Call: 1.877.226.3369 / 905.366.3377 Manual.indd Innovation, Quality and Support! Visit: www.camdencontrols.com...
  • Page 8 WC11PS SERIES RESTROOM CONTROL CX-WC11AXFM-PS Wiring Diagram with CX-WEC10-K2 Integration INS TA LL AT I ON I N S T RU CTI O N S 120 VAC Electric Strike Transformer CX-ED2079 CX-TRX-5024 + Lock 24 VAC, 50 VA + Strike...

This manual is also suitable for:

Cx-wc series