Getting Started Guide
Software &
Documentation
To download software, the 8100 User Manual,
and other supporting documentation scan
the QR code here or on the tester to visit
downloads.cirris.com.
downloads.cirris.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CIRRIS 8100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Komax CIRRIS 8100

  • Page 1 8100 Getting Started Guide Software & Documentation To download software, the 8100 User Manual, and other supporting documentation scan the QR code here or on the tester to visit downloads.cirris.com. downloads.cirris.com...
  • Page 2: Getting Started

    Alerts users to a risk of personal injury or damage to the equipment. Intended Use Cirris 8100 systems are designed for electrical testing and are intended to be used indoors, in a dry environment, at a temperature of 50-104 degrees Fahrenheit (10-40 degrees Celsius) at less than 70% relative humidity (non- condensing).
  • Page 3: System Components

    System Components ☐ ☐ Base Wrist Strap 8100 BASE Probe 8100 Low Voltage Tester ☐ ☐ USB Cable Probe ☐ Certificate of Calibration Optional Expansion Units: ☐ ☐ Expansion Expansion Cable 8100 EXPANSION Probe 8100 Low Voltage Tester Additional Optional Items: ☐...
  • Page 4 Configurations The most basic 8100 system consists of a Base with 256 test points connected to a PC by a USB cable. As no separate power cord is required, this makes an extremely compact and portable package. 8100 8100 BASE Probe 8100 Low Voltage Tester...
  • Page 5: System Assembly

    System Assembly If the system consists of only a Base, skip to Step 3, otherwise begin with Step 1. On the Rear Panel The first unit in the system must be a Base. Connect an Expansion Cable from Out on the Base to In on the first Expansion unit. To connect additional Expansion units, follow the same process to extend the system daisy-chain by connecting Out on a preceding Expansion (or Base acting as an expansion unit) to In on the following unit.
  • Page 6: Indicator Leds

    On the Front Panel Connect the Probe to the Probe receptacle on the front of the system Base. Note that the probe should never contact external power sources. 8100 BASE Probe 8100 Low Voltage Tester Indicator LEDs The front panel includes an LED in the lower right corner that indicates the status of the unit: Status Description...
  • Page 7: Installing The Software

    Installing the Software Easy-Wire Station Software The purchase of a new 8100 tester includes the latest version of the Easy-Wire Station software. The installation file for the software can be downloaded from the Cirris web site by scanning the QR Code on the tester or at downloads. cirris.com.
  • Page 8 Startup There are no power switches on the 8100 hardware. If properly connected to the PC Controller, the system will receive a power-on command when the Easy- Wire software opens. Open the Easy-Wire software by double-clicking on the desktop icon. If the icon can’t be found, from the Windows task bar, click Start >...
  • Page 9 Activate the Software License After performing a new installation, the Easy-Wire software will be fully functional for 21 days. During this period, the Main Menu displays the license status Temporary License. If the software license is not activated before the end of this time, the software will enter an Edit Only mode, which supports editing functions, but which does not support tester control.
  • Page 10: Changing The Interface Language

    Changing the Interface Language The language used in the Easy-Wire interface can be changed to one of the available options. From the Main Menu > Utilities > Setup System Options. Under the Software Settings tab, select Change. Select a language from the list of options and click OK. Click OK on the Setup System Options window to return to the Main Menu.
  • Page 11: Help & Support

    Calibration New Cirris Base units ship with a Certificate of Calibration valid for one year. Cirris recommends that the calibration be validated annually at a minimum thereafter. The validation can be performed by Cirris, by the end user, or by a calibration service provider using an 8100 Performance Check Kit.
  • Page 12: Warranty

    Warranty Cirris Inc. warrants new products manufactured by Cirris Inc. to be free from de- fects in material and workmanship for a period of twelve months. Products not manufactured by Cirris Inc. are warranted by their manufacturer. Cirris Inc. at its option will repair or replace faulty goods and is not responsible for any conse- quential loss incurred due to faulty goods.