Getting Started Guide
Software &
Documentation
To download software, the Easy-Wire
Software Manual, and other supporting
documentation scan the QR code here or on
the tester to visit downloads.cirris.com.
downloads.cirris.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CIRRIS Easy-Wire 4200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Komax CIRRIS Easy-Wire 4200 Series

  • Page 1 4200 Series with Easy-Wire Getting Started Guide Software & Documentation To download software, the Easy-Wire Software Manual, and other supporting documentation scan the QR code here or on the tester to visit downloads.cirris.com. downloads.cirris.com...
  • Page 2: Getting Started

    Getting Started As an option, Cirris 4200 and 4250 testers can be controlled by the Easy-Wire software. In this configuration, the 4200 Series tester functions much like a Cirris Easy-Touch Pro® tester, except that the Easy-Wire software is installed on a separate PC instead of on the Easy-Touch’s integrated PC.
  • Page 3: Intended Use

    ● Not to not touch the product or test fixture hardware during high voltage testing. A safe test station is an essential complement to training: ● Use a non-conductive work surface to avoid creating an unintended elec- trical path between high voltage and workers. ●...
  • Page 4: Hardware Setup

    Unpacking At a minimum, the package in which the tester was shipped should have included the following items: ☐ ☐ 4200 or 4250 Tester USB Cable ☐ ☐ Probe Power Supply and Cord ☐ Certificate of Calibration ☐ WiFi Antenna Hardware Setup The tester includes 128 test points in the base enclosure.
  • Page 5: Installing The Software

    Installing the Software Easy-Wire Station Software The installation for the Easy-Wire software can be downloaded from the Cirris web site by scanning the QR Code on the tester or at downloads.cirris.com. PC Requirements ● Windows® 10 Pro or Windows 11 ●...
  • Page 6 Startup If the tester is not powered on, do so now by pressing the power button on the rear panel of the unit. Once the Easy-Wire software is configured, it will not be necessary to manually power on the unit as opening the Easy-Wire software will automatically start the tester.
  • Page 7 Activate the Software License After performing a new installation, the Easy-Wire software will be fully functional for 21 days. During this period, the Main Menu displays the license status Temporary License. If the software license is not activated before the end of this time, the software will enter an Edit Only mode, which supports editing functions, but which does not support tester control.
  • Page 8 Fixturing 4200 Series testers use interchangeable adapters as the interface for connecting the tester to the Device Under Test (DUT). Standard adapters are available with a wide variety of connector types (a complete list can be found on the Cirris web site). However, if the DUT includes connectors that have no direct adapter mates, test cables can be used to connect the connector on a standard Cirris adapter to the DUT connector.
  • Page 9 Create a New Test Program Before a device can be tested, a test program must be created. This is most often accomplished by using the tester’s capability to “learn” a sample product. Once a test program has been created, it can be saved and then loaded as needed to test subsequent batches of the same product.
  • Page 10 Verify and Edit the Test Program When the learn is complete, the test program will open in the Test Program Editor to the Define Instructions tab. Verify that the learned instructions match the product’s documentation. Click/tap Help on any screen for guidance. Define Instructions Tab ●...
  • Page 11 Test To load a test program for a test session, from the Main Menu, click/tap a test program name to highlight it > Test. Depending on the Start Condition, either attach a cable to start the test automatically or attach a cable and click/tap Start. Low voltage testing is performed first and may take less than a second to complete.
  • Page 12: Help & Support

    Documentation In addition to this Getting Started Guide, there are several resources that pro- vide important information about the test system and its operation. The Easy- Wire Help is installed with the software. Software, manuals, and other documen- tation can be downloaded from the Cirris web site at downloads.cirris.com or by scanning the QR code on the tester.