POWER VENT INSTALLATION INSTRUCTIONS
HORIZONTALLY TERMINATED
NOTE: This kit must be installed by a qualified installer. These instructions are to be used in conjunction
with the fireplace installation manual to insure proper installation.
AA-11-04071 – Power Vent Kit: Vent runs up to 25 feet in length.
AA-11-04072 – Power Vent Kit: Vent runs over 25 feet and up to 80 feet in length.
This component kit is to be with all Power Vent Kits
AA-11-05379 Power vent component kit for 4" x 6-5/8" vented fireplaces. The
installation Manual is at the end of this document.
ATTENTION: This installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. All electrical installations
should be performed by a qualified electrician to the Canadian and U.S. National Electrical Codes (CSA C22.1 for
Canada), (ANSI/NFPA 70 for the U.S.) and/or local electrical codes.
PAINT: The power vent comes painted a cream color. The power vent can be painted to match your wall finish color
using high temperature paint. Paint used must be able to withstand temperatures of at least 250 degrees Fahrenheit.

Tools

-
Phillips Head Screw Drive
-
Torx Head Driver
-
Square Head Driver.
¼" Hex Driver.
-
-
Wire Stripper
-
Caulk Gun
Components – NOT INCLUDED WITH THE POWER VENT.
-
14/2 SOLID COPPER WIRE
The power vent kit must be wired to the fireplace using 14/2 solid copper wire. Required wire
length will depend on vent run length.
-
SILICONE CAULK
Used to seal around the power vent.
OPTIONAL – HIGH TEMP PAINT
-
The power vent comes painted a cream color. The power vent can be painted to match your
wall finish color using high temperature paint. Paint used must be able to withstand
temperatures of at least 250 degrees Fahrenheit.
85-03-01131

REQUIRED TOOLS AND COMPONENTS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AA-11-04071 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mendota AA-11-04071

  • Page 1: Required Tools And Components

    NOTE: This kit must be installed by a qualified installer. These instructions are to be used in conjunction with the fireplace installation manual to insure proper installation. AA-11-04071 – Power Vent Kit: Vent runs up to 25 feet in length. AA-11-04072 – Power Vent Kit: Vent runs over 25 feet and up to 80 feet in length.
  • Page 2: Table Of Contents

    Table of Contents REQUIRED TOOLS AND COMPONENTS ..........................1 Tools ....................................1 Components – NOT INCLUDED WITH THE POWER VENT....................1 POWER VENT KIT SERVICE PARTS ........................... 3 DIMENSIONS..................................3 AESTHETIC CONSIDERATIONS ............................4 CLEAN FACE INSTALLATION ............................4 PAINT ....................................
  • Page 3: Power Vent Kit Service Parts

    POWER VENT KIT SERVICE PARTS DIMENSIONS Page 3 of 22 85-03-01131...
  • Page 4: Aesthetic Considerations

    AESTHETIC CONSIDERATIONS CLEAN FACE INSTALLATION This power vent is designed so that it can be mounted at different depths in 1 1/2" intervals. This allows the power vent to be installed flush with the exterior wall, helping to maintain the beauty of your home’s exterior. WARNING: The power vent box must be flush or protruding to the finished outside wall.
  • Page 5: Venting Configurations

    • For horizontally terminated vent runs that are under 25 feet power vent kit AA-11-04071 must be used. • For horizontally terminated vent runs that are over 25 feet power vent kit AA-11-04072 must be used.
  • Page 6: Exterior Vent Locations And Restrictions

    EXTERIOR VENT LOCATIONS AND RESTRICTIONS Note: All measurements are to be taken from the edge of the Power Vent. Page 6 of 22 85-03-01131...
  • Page 7: Installing Power Vent Kit

    INSTALLING POWER VENT KIT FRAMING THE POWER VENT 1. Determine the location of the power vent termination on the exterior wall. Be sure to follow all clearance restrictions in the exterior vent location and restrictions chart in this manual. 2. Cut and frame a 14 5/8” wide by 14 7/8” high opening in the wall. NOTE: The vent pipe is not centered vertically on the power vent.
  • Page 8 4. After the mounting flange has been attached to the power vent box, slide the assembly through the framed hole. Secure the outer flanges on the mounting flange to the outside wall. Ensure that the power vent is the right way up (exhaust at the bottom).
  • Page 9 7. Slide the wall pipe cover, with the small notch oriented at the top, over the vent pipe. Attach the vent pipe to the power vent. Attach the wall pipe cover to the inner wall plate. This ensures that any insulation is retained in the wall and that the correct clearances are maintained.
  • Page 10: Wiring The Power Vent

    WIRING THE POWER VENT The fireplace will have a junction box with two strain relief clamps. See the installation manual included with the fireplace for the location of the junction box. To connect the power vent to the fireplace, follow these steps. Remove the junction box cover plate from the side of the fireplace.
  • Page 11 At the other end, the power vent wire must be wired to the power vent blower housing. The power vent has an electrical connector block mounted internally. The wiring must be connected to this block. To access the block first remove the decorative cover and blower cover from the power vent. Remove the screws shown in the photos below to remove the decorative cover and blower cover.
  • Page 12 POWER VENT KIT INSTALLATION INSTRUCTIONS AA-11-05379 Power vent component kit for 4” x 6-5/8” vented fireplaces. Tools Needed - Large Flat Blade Screwdriver - Wire Cutters CONTROL MODULE PREPERATION The board will need to be opened to remove a component inside for the power vent to be operational. This can be done with the board still in the fireplace or it can be removed from the fireplace for easier access.
  • Page 13 2. Locate the pin cover circled in the top photo. Grab it with your fingers and pull it straight up to remove it. You may discard this piece. Page 13 of 22 85-03-01131...
  • Page 14 3. Place the top cover back onto the control module, make sure it is oriented properly, press lightly on the top cover till you hear a clicking sound engaging the retaining clips. 4. Re-install the control module back into the fireplace if it was removed. Page 14 of 22 85-03-01131...
  • Page 15 PRESSURE SWITCH PREPARATION To begin preparation on the pressure switch you will first need to find the pressure switch, silicone hose, and power vent harness. The pressure switch and silicone hose are in the same box as these instructions. The power vent harness is the yellow harness with red quick connect connectors in the fireplace manual box.
  • Page 16 2. Locate the end of the power vent wire harness with two female connectors. Connect this end of the power vent wire to the two silver terminals on the pressure switch marked “NO” and “COM”. These can be connected in either order it does not make a difference. Take the silicone hose and attach it to the hose barb on the pressure switch marked “L”.
  • Page 17 The pressure switch will be installed in the fireplace near the control module. The pressure switch must be installed vertically. The photos in the instructions show the pressure switch being placed in a ML series fireplace. For all fireplaces the presser switch can be placed next to the control module in a similar way.
  • Page 18 (ML-Series fireplaces) Route the silicone hose through the rear cutout of the fireplace. The cutout is located near the center of the fireplace at the bottom on the backside. The silicone hose can be routed from this hole to the pressure switch. (FV-Series fireplaces) Route the silicone hose through the cut out in the access panel where the gas line is connected.
  • Page 19 WIRE HARNESS PREPARATION The wire harness needs to be modified for the power vent to be operational. You will need the wire cutters to remove a wire from the harness. The harness that needs to be modified will come already installed into the fireplace.
  • Page 20: Fireplace Preparation

    FIREPLACE PREPARATION Use Kit AA-11-05379 for the following steps. Note: For the following units DXV35DT4, FV34, FV34 ARCH, FV34 DÉCOR. Start with the 4 x 6 vent adapter with the pressure plate. Install the 5/8-4 x 6 reducer. 2. Attach the 4 x 6 vent adapter with pressure plate to the reducer in item one. Note: the height of the reducer and adapter attached is 11 ½”.
  • Page 21 3. Install the 4 x 6- 5/8 increaser to the power vent. Page 21 of 22 85-03-01131...
  • Page 22 REMOVE CPI FUNCTION FROM THE REMOTE. Remove the batteries from the remote. Then install the batteries while holding the power and mode buttons. This will bring up a display that will let you select or clear the functions on the remote. Keep the power button held down and use the mode button to toggle between functions.