Mendota AA-11-03781 Installation Instructions Manual
Mendota AA-11-03781 Installation Instructions Manual

Mendota AA-11-03781 Installation Instructions Manual

Cool wall vent kit

Advertisement

Quick Links

Cool Wall Vent Kit Installation Instructions
Cool Wall vent kits AA-11-03781, AA-11-03782 and AA-11-04062
Each vent kit must be used with AA-11-04060.
Approved for use with all Mendota ZC Fireplace models, except M27.
NOTE: This kit must be installed by a qualified installer. These instructions are to be used in conjunction
with the fireplace installation manual to insure proper installation.
These kits are designed to use natural convection to transfer warm air from the front of the fireplace to
a different location. The kits allow the warm air from the fireplace to enter the room farther up on the
fireplace chase front wall or side wall. This results in much lower breastplate, mantel and wall
temperatures above the top convection chamber of the fireplace.
85-03-01096

REQUIRED TOOLS FOR INSTLALLATION

▪ Phillips Screw Driver
▪ Flat Screw Driver
▪ 1/4" Hex Head Driver
▪ 5/16" Hex Head Driver
▪ Drill or Impact Driver

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AA-11-03781 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mendota AA-11-03781

  • Page 1: Required Tools For Instlallation

    Cool Wall vent kits AA-11-03781, AA-11-03782 and AA-11-04062 Each vent kit must be used with AA-11-04060. Approved for use with all Mendota ZC Fireplace models, except M27. NOTE: This kit must be installed by a qualified installer. These instructions are to be used in conjunction with the fireplace installation manual to insure proper installation.
  • Page 2: Table Of Contents

    USE OF FIREPLACE FANS WITH THE COOL WALL KIT ....................3 KIT CONTENTS ..................................4 AA-11-03781 – 48” X 2” VENT BOX AND TRIM KIT ......................4 AA-11-03782 – 36” X 2” VENT BOX AND TRIM KIT ......................5 AA-11-04062 – DUAL 12” X 4” VENT BOX KIT ........................6 PLANNING FOR VENT LOCATION ............................
  • Page 3: General Information

    USE OF FIREPLACE FANS WITH THE COOL WALL KIT Mendota fireplaces come with warm air fans included. When a Cool Wall kit is installed on the fireplace and the fans are turned on the wall temperatures above the fireplace will increase. The fans will force some of the heated air out the front of the top convection opening on the fireplace.
  • Page 4: Kit Contents

    KIT CONTENTS AA-11-03781 – 48” X 2” VENT BOX AND TRIM KIT This kit contains the following parts. PART NUMBER DESCRIPTION 48” X 2” VENT BOX HA-118-00001 HA-117-00005 VENT GUIDE BOTTOM HA-117-00004 VENT GUIDE TOP HA-117-00006 SUPPORT BRACKET 48” X 2” VENT TRIM HA-118-00002 #8 X ½”...
  • Page 5: Aa-11-03782 - 36" X 2" Vent Box And Trim Kit

    AA-11-03782 – 36” X 2” VENT BOX AND TRIM KIT This kit contains the following parts. PART NUMBER DESCRIPTION 36” X 2” VENT BOX HA-118-00003 HA-117-00015 VENT GUIDE BOTTOM HA-117-00014 VENT GUIDE TOP HA-117-00006 SUPPORT BRACKET 36” X 2” VENT TRIM HA-118-00004 #8 X ½”...
  • Page 6: Aa-11-04062 - Dual 12" X 4" Vent Box Kit

    AA-11-04062 – DUAL 12” X 4” VENT BOX KIT This kit contains the following parts. PART NUMBER DESCRIPTION HA-118-00005 12 X 4 VENT BOX HA-117-00020 VENT GUIDE BOTTOM HA-117-00019 VENT GUIDE TOP HA-117-00006 SUPPORT BRACKET 12” X 4” SIDEWALL GRILL 65-06-01453 #8 X ½”...
  • Page 7: Planning For Vent Location

    Many television manufacturers specify in their installation instructions that the television must not be installed near or above a heat source. The decision to install a television near or above a Mendota fireplace rests solely on the consumer. It is the consumers responsibility to satisfy television specifications and insure the television will not exceed maximum operation temperatures.
  • Page 8 The Mendota Cool Wall system uses natural convection to take heat off the wall directly above the fireplace and redirects it up and away from surrounding areas. Testing has shown that when using a Cool Wall system, temperatures above the fireplace are reduced making it possible to mount a television 15”...
  • Page 9: Aesthetic Considerations

    AA-11-03781 – 48” X 2” VENT BOX AND TRIM KIT This vent box and trim are designed to be installed above the fireplace. The vent box has a simple slot opening that is 48”...
  • Page 10: Aa-11-03782 - 36" X 2" Vent Box And Trim Kit

    AA-11-03782 – 36” X 2” VENT BOX AND TRIM KIT This vent box and trim kit is designed to be installed above the fireplace. The vent box has a simple slot opening that is 36” wide and 2” tall. The vent box and trim come painted black but can be repainted to match room décor if desired. It is recommended that this 36”...
  • Page 11: Minimum Framing Dimensions

    MINIMUM FRAMING DIMENSIONS In addition to these dimensions, consult the installation manual for the fireplace that the vent will be installed with. The minimum framing dimensions may need to be increased to accommodate the fireplace or vent kit. Be sure to understand all factors that will affect the placement of the fireplace and these vent kits before beginning construction.
  • Page 12: Vent Height Above Fireplace

    VENT HEIGHT ABOVE FIREPLACE The vent box must be located at least 30 inches and up to 12 feet above the top of the fireplace. To meet the minimum height requirement when framing for the vent guides the bottom framing 2x4 must be at least 24” above the top of the fireplace.
  • Page 13: Clearance To Fireplace Direct Vent

    CLEARANCE TO FIREPLACE DIRECT VENT When planning the location of the Cool Wall vent box and trim kit be sure to consider how the fireplace exhaust vent system is to be installed. For example, if the fireplace must be vented vertically, make sure there will be room for the direct vent duct from the fireplace to pass by the Cool Wall Vent.
  • Page 14: Installation Instructions

    INSTALLATION INSTRUCTIONS PREPARING FIREPLACE FOR INSTALLATION OF KIT 1. Locate the two circular cutouts on top of the fireplace. Use a side cutter or tin snips to cut the tabs around the perimeter of the circle and remove the cutout. 2.
  • Page 15: Preparing Vent Components For Installation

    4. Use the collar clips and self-drilling screws to secure the vent pipe to the top of the fireplace. Make sure the vent pipe is pushed down against the inner shield while attaching the collar clips. PREPARING VENT COMPONENTS FOR INSTALLATION 1.
  • Page 16: Installing The Vent

    INSTALLING THE VENT See the sections in these instructions PLANNING FOR VENT LOCATION and FRAMING DIMENSIONS. Follow the information in these sections to plan out the installation before proceeding. NOTE: These instructions show a 48” x 2” vent. The other vent sizes install in the same way. 1.
  • Page 17 2. Place the vent box support brackets as shown and screw them in a couple of places to the framing. The bottom of the brackets rest against the bottom framing 2 x 4 and can be pushed up against the framing guide plate. The side of the bracket with one row of holes must be facing up.
  • Page 18 4. The distance the vent box outlet sticks out the front of the framing guides is adjustable up to 4”. It is important at this time to know how deep the finishing material around the vent will be so that the vent box outlet can be set at the correct depth.
  • Page 19 6. Next use the flex vent to connect the vent pipe that was installed on top of the fireplace to the starter collars that are located on the vent box. Cut the vent to length and pull it tight between the two connections. Use the 8” hose clamps to hold the flex vent to the starter collars on the vent box and rigid pipe on the unit.
  • Page 20: Finishing Around Vent Box And Installing Vent Trim/Grill

    FINISHING AROUND VENT BOX AND INSTALLING VENT TRIM/GRILL ATTENTION: Finishing material used around the vent box can be up to 4” thick. Finishing material that is placed over the metal framing guide must be non-combustible. 1. Place finishing material around the vent box outlet. The finishing material can be placed up to the edges of the vent box opening, but it cannot cover the opening of the vent box.
  • Page 21: Recommendation 3: Install A Heat Transfer System

    Mendota Cool Wall The Mendota Cool Wall system uses natural convection to take heat off the wall directly above the fireplace and redirects it up and away from surrounding areas. Testing has shown that when using a Cool Wall system, temperatures above the fireplace are reduced making it possible to mount a television 15”...
  • Page 22 Page 22 of 22 85-03-01096...

This manual is also suitable for:

Aa-11-03782Aa-11-04062

Table of Contents