Explosion-Protected Fixed Camera (防 防 防 爆 爆 爆 固 固 固 定 定 定 カ カ カ メ メ メ ラ ラ ラ ) Specific conditions of use WARNING Always refer to the product certificates for any specific conditions of use. •...
Cable gland and blanking element To fulfil JPEx certification, F31111 devices must be installed with the specified cable gland for armored cables and the specified blanking element.
Page 7
Explosion-Protected Fixed Camera (防 防 防 爆 爆 爆 固 固 固 定 定 定 カ カ カ メ メ メ ラ ラ ラ ) For detailed installation instructions of the cable gland, see the manufacturer's installation manual (CMP T3CDS Fitting Instructions Fl408 JP). Cable gland Manufacturer Thread type...
Page 8
Explosion-Protected Fixed Camera (防 防 防 爆 爆 爆 固 固 固 定 定 定 カ カ カ メ メ メ ラ ラ ラ ) Blanking element (Continued) Specific conditions of use to be considered for The blanking element is provided with an installation with P21 additional sealing washer in nylon.
Page 9
Ensure that the voltage is correct before beginning any maintenance or connections. • Use suitably color coded conductors or other means of identification. • Earthing conductors should be green and yellow. • Take extra care to not damage the thread form. Wiring of F31111 Earth supplemental bonding Auxiliary OUT connector...
Page 11
Explosion-Protected Fixed Camera (防 防 防 爆 爆 爆 固 固 固 定 定 定 カ カ カ メ メ メ ラ ラ ラ ) Use an RJ45 connector (CAT5 or higher) for network connection. Optionally, an SFP slot is available for an alternative network connection, this port utilizes various SFP modules including fiber optic.
Battery Devices of type F31111 use a 3.0 V BR2330A lithium battery as the power supply for its internal real-time clock (RTC). Under normal conditions this battery will last for a minimum of five years. Low battery power affects the operation of the RTC, causing it to reset at every power-up. When the battery voltage is low, a log message will appear in the product’s server report.
Markings You can find the markings on the devices’ main body. Note Information below is only an example. For specific information, see the product’s datasheet. Manufacturer’s name and address Axis Ex AB Gränden 1 SE-223 69 LUND SWEDEN Type F31111...
Page 14
Explosion-Protected Fixed Camera (防 防 防 爆 爆 爆 固 固 固 定 定 定 カ カ カ メ メ メ ラ ラ ラ ) Certifications may vary between different models. Certificates and standards F31111 JPEx certificate number DEK24.0019X JNIOSH standards applied...
Further information • The user manual is available at axis.com • To check if there is updated firmware available for your device, see axis.com/support • For useful online trainings and webinars, see axis.com/academy Optional accessories For a complete list of available accessories for this product, go to the product’s page on axis.com and select Software &...
Explosion-Protected Fixed Camera (防 防 防 爆 爆 爆 固 固 固 定 定 定 カ カ カ メ メ メ ラ ラ ラ ) Safety information Hazard levels DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury.