WesAudio DIONE User Manual

WesAudio DIONE User Manual

Analog sound digital recall

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIONE and is the answer not in the manual?

Questions and answers

Summary of Contents for WesAudio DIONE

  • Page 2 WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 www.WesAudio.com _DIONE User manual Copyright 2024 by WesAudio...
  • Page 3 WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 _DIONE Thank You for the purchase of Stereo Bus Compressor with digital recall With kind regards Radoslaw Wesolowski and Michal Weglicki...
  • Page 4 "mixbus glue." For over 40 years, this iconic compressor sound has been a staple in the industry. Introducing the DIONE — a fully analog VCA compressor with the convenience of digital recall, delivering the legendary sound with modern functionality.
  • Page 5: Table Of Contents

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 TABLE OF CONTENTS Overview ..............................7 Main Features .............................. 7 Hardware ..............................8 3.1 Specification ............................... 8 3.2 Installation and Compatibility ........................9 3.3 Front Panel and Main Functions ....................... 11 3.4 LEDs ................................13 Analog Processing .............................
  • Page 6 WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 8.1 Hookup Diagram – Analog Cables With _TITAN ..................29 8.2 Hookup Diagram – _CALYPSO and _TITAN ....................30 8.3 Hookup Diagram – 500 Series Chassis ..................... 31 8.4 Other examples ............................32 Troubleshooting ............................33 Abbreviations and Terms ...........................
  • Page 7: Overview

    _DIONE USER MANUAL REV4 1 Overview _ DIONE is a stereo VCA bus compressor for 500 series racks with analog sound and digital control. It offers recallable settings, DAW automation, and flexible controls, including sidechain filtering and adjustable attack and release. With its seamless integration into modern studios, DIONE is perfect for those wanting classic analog compression with the convenience of digital recall.
  • Page 8: Hardware

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 3 Hardware This chapter will go through all analog features and explain all hardware aspects of _DIONE. 3.1 Specification Frequency response 20Hz-20kHz (0.1dB) THD+N (WET) 0.008% (1kHz, 0dBu) THD+N (DRY) 0.004% (1kHz, 0dBu) Input impedance...
  • Page 9: Installation And Compatibility

    An API™ 500 Series compatible rack • _TITAN or any other ng500 compatible chassis, WesAudio's _DIONE module isn't standalone; it needs power from the rack system to function. When unpacking, check for any damage caused during shipping. If there's a problem, contact your dealer immediately!
  • Page 10 _DIONE USER MANUAL REV4 500 series compatibility note: Each WesAudio device within the ng500 (Next Generation 500 series) lineup comes with a unique connector. This specialized connector serves as an extension to the standard 500 series, enabling your device to be controlled and recalled using the specialized GCon protocol. For instance, this connector allows compatibility with the _Titan 500 series 10-slot frame.
  • Page 11: Front Panel And Main Functions

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 3.3 Front Panel and Main Functions...
  • Page 12 WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 1) Threshold: Adjusts the level at which the compressor starts to engage, continuously adjustable from -20 dB to +20 dB. 2) Mix: Blends the wet (compressed) and dry (uncompressed) signals, enabling parallel compression. 3) Make Up: Adjusts the output gain to compensate for compression, with a range from 0 to 20 dB, ensuring consistent signal levels after gain reduction.
  • Page 13: Leds

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 3.4 LEDs The unit offers two LED operation modes: • Normal Mode: LEDs light up in a clockwise sequence, indicating the overall level of a specific parameter. • Single LED Indicator Mode: Each parameter is represented by a single LED, similar to a knob with an indicator.
  • Page 14: Analog Processing

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 4 Analog Processing 4.1 VCA Compression _DIONE uses VCA compression to manage the audio signal's dynamic range. In a VCA compressor, the gain of the signal is controlled by a voltage, allowing the compressor to react quickly and accurately to changes in the audio’s volume.
  • Page 15 WESAUDIO 8/28/24 _DIONE USER MANUAL REV4...
  • Page 16: Software Setup

    8/28/24 _DIONE USER MANUAL REV4 5 Software Setup The WesAudio software package is accessible for download to all purchasers of the corresponding hardware unit at https://www.wesaudio.com/download For information on supported plugin types and platforms, please refer to the provided link.
  • Page 17: Troubleshooting

    If you encounter any issues during the installation process, please reach out to our support team at support@wesaudio.com, and we will respond promptly to assist you. Below is a common issue along with suggestions that might help in diagnosing the problem: •...
  • Page 18: Gcon Manager

    The GCon Manager is a versatile application designed for configuration management across compatible devices. It is located within the Application folder data: • For OSX: Access it at “/Applications/WesAudio/GConManager.” • For WINDOWS: Find it in the folder chosen during the installation phase, typically “c:/Program Files x86/WesAudio/GConManager.exe”...
  • Page 19: How To Check Firmware Version

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 5.3 How To Check Firmware Version Each device communicates its firmware version to your workstation, establishing compatibility between your host application and the connected device. To verify the firmware version or perform an upgrade, please use the GConManager _CONFIG application.
  • Page 20: How To Perform Firmware Upgrade

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 5.4 How To Perform Firmware Upgrade To update the firmware, navigate to the GConManager UPGRADE section and press the “Start” button. This starts the update process for any modules that do not have the latest firmware version.
  • Page 21: Digital Control / Recall

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 6 Digital Control / Recall This chapter delves into the comprehensive options available for managing _DIONE and automating its settings. The cornerstone of _DIONE's automation capabilities is its integration with Digital Audio Workstations (DAW) through a plugin, which is available in all common formats. This seamless convergence between hardware and digital software opens a wide array of creative possibilities and enhances workflow efficiency.
  • Page 22: Daw Plug-In

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 6.1 DAW Plug-in The _DIONE plug-in extends comprehensive control over all parameters of the unit, ensuring seamless integration into any digital audio workstation (DAW) environment. Designed to be versatile and accessible, it supports all common plug-in standards, including VST2, VST3, AU (Audio Units), and AAX, making it compatible with a wide range of software platforms.
  • Page 23: Plugin Structure

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 6.1.1 Plugin Structure...
  • Page 24 WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 For detailed explanations of each control and its functionality, users are encouraged to consult the chapter titled "Front Panel Functions." This section provides comprehensive insights into how to interact with the _DIONE, whether you're adjusting parameters on the physical unit or via the plug-in.
  • Page 25 WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 23. The Select Connection Button within the _RHEA plug-in serves as a gateway to establishing and managing connections with devices that support the GCon protocol. This feature simplifies the process of identifying and selecting the hardware unit to be controlled, providing a user-friendly interface for seamless integration between the plug-in and physical devices.
  • Page 26: Other Functions

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 7 Other Functions 7.1 Memories In terms of parameter storage: The _DIONE unit offers TWO distinct quick-access presets, selectable via the A/B buttons . In contrast, the _DIONE plugin supports saving an UNLIMITED number of configurations. Each preset within the plugin provides three rapid configuration changes, labeled A/B/C per bank ID.
  • Page 27: Metering

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 7.2 Metering _DIONE unit features an analog Gain Reduction (GR) meter that provides real-time visual feedback on the amount of compression being applied. This meter is essential for monitoring the dynamics of your signal, allowing you to see how much gain reduction is occurring as you adjust the compressor’s settings.
  • Page 28: Sidechain

    No additional actions are needed on the hardware side to enable this feature; simply configure the sidechain signal within the WesAudio plugin, just as you would with any other plugin. Below is a high-level diagram showing a possible setup for connecting the hardware unit to use the sidechain feature.
  • Page 29: Hookup Diagrams

    8/28/24 _DIONE USER MANUAL REV4 8 Hookup Diagrams Below chapter shows possible hookup of the WesAudio devices and audio interface. 8.1 Hookup Diagram – Analog Cables With _TITAN Audio interface OUTs to _TITAN INs _TITAN OUTs to Audio Interface INs...
  • Page 30: Hookup Diagram - _Calypso And

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 8.2 Hookup Diagram – _CALYPSO and _TITAN ADAT I/O - _CALYPSO in _TITAN chassis converts and distributes analog signal internally in the chassis Control and Recall of the units (*) PLUG-IN which controls hardware unit Computer to Audio Interface connection (USB/TB etc.)
  • Page 31: Hookup Diagram - 500 Series Chassis

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 8.3 Hookup Diagram – 500 Series Chassis Audio interface OUTs to 500 chassis INs 500 series chassis OUTs to Audio Interface INs Each module USB socket needs to be connected either directly or via USB HUB...
  • Page 32: Other Examples

    _DIONE USER MANUAL REV4 8.4 Other examples Please note that all WesAudio units, despite their digital recall and control capabilities, remain fully analog and can be utilized at any stage of the production process, including recording and post-processing. For instance, like any other units, WesAudio modules can be seamlessly integrated during tracking.
  • Page 33: Troubleshooting

    • No Sound Output or Signal Loss • Unexpected Distortion • Thumping or Low-End Artifacts • Inconsistent Compression • No Response to DAW Automation • Excessive Heat Please visit the WesAudio FAQ site https://wesaudio.com/faq/ for detailed troubleshooting steps and solutions.
  • Page 34: Abbreviations And Terms

    WESAUDIO 8/28/24 _DIONE USER MANUAL REV4 10 Abbreviations and Terms GCon is a high-speed communication protocol developed to enable complete management and recall of analog devices. It's important to note that GCon is solely focused on device control and management; it does not facilitate the transfer of audio signals.
  • Page 35: Warranty

    _DIONE USER MANUAL REV4 11 Warranty WesAudio is committed to delivering products of the highest quality, designed for durable and reliable performance over many years, assuming proper care, usage, transport, and storage. Our products come with a two-year warranty covering defects in parts and workmanship from the original date of purchase.

Table of Contents