Flintec FT-112 User Manual

Weighing terminal
Hide thumbs Also See for FT-112:
Table of Contents

Advertisement

Quick Links

FT-112
Weighing Terminal
User Manual
Flintec
www.flintec .com
FT-112 User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FT-112 and is the answer not in the manual?

Questions and answers

Summary of Contents for Flintec FT-112

  • Page 1 FT-112 User Manual FT-112 Weighing Terminal User Manual Flintec www.flintec .com...
  • Page 2: Table Of Contents

    Electrical Connection Recommendations ......................16 Installation Steps ................................17 Cleaning ..................................27 Disposal ..................................27 FT-112 Functions ................... 28 Basic Functions ................................28 Advanced Functions ..............................29 Backup and Restore (with SD card) ........................35 Setup, Backup and Restore via Indface2x Software ..................35 Firmware Upgrade ..............................
  • Page 3 Working with two Scales (FT-112) ........... 77 Identification Data Record (ID1, ID2) ..........78 Digital Inputs -Outputs / Setpoints and Limits ......80 10.1 Electrical Connection ..............................80 10.1.1 Digital Inputs ................................80 10.1.2 Digital Outputs: ................................80 10.2 Basic Weighing ................................87 10.3...
  • Page 4 Appendix 1: Data Structure Profibus, Profinet, EtherNET/IP, EtherCAT, CC-Link, Powerlink ..............155 Appendix 2: Data Structure CANopen ........165 Sealing of Approved Scale .............. 175 Trouble Shooting ................176 FT-112 User Manual Rev. 2.0.0, June 2022 Page 3 of 180...
  • Page 5: Safety Instructions

    Flintec reserves the right to revise this manual and alter its content without notification at any time. Neither Flintec nor its affiliates shall be liable to the purchaser of this product or third parties for damages, losses, costs, or expenses incurred by purchaser or third parties because of: accident, misuse, or abuse of this product or unauthorized modifications, repairs, or alterations to this product, or failure to strictly comply with Flintec operating and maintenance instructions.
  • Page 6: Introduction

    500 items for average piece weight memory. The scales equipped with FT-112 weighing terminal can be used in all kinds of industrial areas including wet and hygienic environments with their fast and efficient cleaning built according to international guidelines.
  • Page 7 Weighing functions tare status is saved at power off, increased resolution, automatic tare and tare clear, temporary gross indication, unit change (only FT-112). Labeling, piece counting, checkweighing, classifying, filling, packing, free setpoints, functional outputs, totalization, livestock weighing, Remote IO or PLC...
  • Page 8 Alternatively, 4 wires with 24 Volt power supply over the bus Max. Stations Up to 127 stations per network Isolation Galvanically isolated bus electronics Response speed Min. 4 ms response delay after read/write commands FT-112 User Manual Rev. 2.0.0, June 2022 Page 7 of 180...
  • Page 9 100% free choice of star, tree, ring or daisy chain Switched Ethernet transmission with shielded twisted pair cables and RJ-45 Installation connectors. Isolation Galvanically isolated bus electronics Response speed Min. 4 ms response delay after read/write commands FT-112 User Manual Rev. 2.0.0, June 2022 Page 8 of 180...
  • Page 10 Power Consumption 100 240 VAC max. 75 mA or 12 28 VDC max. 750 mA (FT-112) Environment and Enclosure: Approved scales -10 °C to +40 °C Operation temp. range Industrial usage -15 °C to +50 °C Humidity 85% RH max, non-condensing...
  • Page 11: Housing

    This kit can be used to install the weighing terminal on to the desk or to the wall. Its mounting dimensions and adjustment angles are shown below. Mounting part Side view Rear part of indicator FT-112 User Manual Rev. 2.0.0, June 2022 Page 10 of 180...
  • Page 12: Wall Mounting Kit

    This kit can be used to install the weighing terminal on to the column of the platform. Its mounting dimensions and adjustment angles are shown below. Mounting part Side view FT-112 User Manual Rev. 2.0.0, June 2022 Page 11 of 180...
  • Page 13: The Front View And Key Functions

    RONT IEW AND UNCTIONS Figure 3.1 Front view of FT-112 3.1 Display The bright and wide-angle LCD display of the FT-112 is shown below. FT-112 User Manual Rev. 2.0.0, June 2022 Page 12 of 180...
  • Page 14: Key To The Symbols Displayed On The Display Are

    Diplays that the scale is being used with preset tare after entering the specified tare value. Announces the weighing indicator is in piece counting mode. Indicates that keylock is enabled. Indicates the battery charge level FT-112 User Manual Rev. 2.0.0, June 2022 Page 13 of 180...
  • Page 15: Key Pad

    3.2 Key Pad The keys and the key functions of FT-112 in usage are: On. Press the key to switch on the weighing terminal. Off. Press the key for more than 2 seconds to switch of the instrument. Page 78, Identification data.
  • Page 16: Installation

    Figure 4.2 - Ground pins in FT-111 (D) for cable shield grounding Warning: Incorrectly closed back cover and poorly tightened glands may be unwanted results with loss of IP FT-112 User Manual Rev. 2.0.0, June 2022 Page 15 of 180...
  • Page 17: Electrical Connection Recommendations

    230 VAC DIP switch J14, automatic Ethernet Connectors of Alibi Connector of switch on. optional board Second Scale (Option card (If short circuit) (Option) Figure 4.3 FT-111 The main board FT-112 User Manual Rev. 2.0.0, June 2022 Page 16 of 180...
  • Page 18: Installation Steps

    Before starting the installation, Select the weighing terminal location. Refer to recommendations in the previous section. 2. Prepare the Protective Earth (PE) cable to grounding the FT-112 (D) housing. The protective earth should be as good as possible for scale reliability.
  • Page 19: Wall Mounting

    3 rear of the instrument the picture. screws. with 4 x m5 x 15mm screws. Mounting part Side view Rear part of inidcator FT-112 User Manual Rev. 2.0.0, June 2022 Page 18 of 180...
  • Page 20: Column Mounting

    Install the small part of the kit Assemble the kit as seen in the Use 4 pcs M5 x 15 mm screws to the column. picture. for installing. Mounting part Side view FT-112 User Manual Rev. 2.0.0, June 2022 Page 19 of 180...
  • Page 21 Figure 4.6. In 4-wire installations the sense and excitation pins with the same polarity should be short circuited at the connector side. If you have a junction box in your system, use 6-wire cable between FT-112 and the junction box, and short circuit these pins at junction box for better performance.
  • Page 22 Since the supply voltage of the digital load cell is isolated, its Ground (0 VDC) should NOT be connected to another ground or PE-Protective Earth!!! Figure 4.8 FT-112D, LPK24 and RC3D connection with junction box FT-112 User Manual Rev. 2.0.0, June 2022 Page 21 of 180...
  • Page 23 Figure 4.9 FT-12D, LPK24 and RC3D v2 connection without junction box Step 5: Second Scale Connection (FT-112) If your instrument has the optional second scale board, connect the second platform to the terminals on this board. Figure 4.10 - The load cell connector on the second scale board.
  • Page 24 Step 6: RS 232C Serial Ports (Interface 1 and Interface 2) FT-112 weighing terminal has 2 x RS232C serial ports on the main board which are galvanically isolated from other circuits to increase the EMC immunity. RS232C serial ports are named as RS232C-1 and RS232C-2 in set up menu and as Int 1 and Int 2 on the electronic board sequentially.
  • Page 25 Step 7: RS 485 Serial Port (Interface 3) FT-112 weighing terminal has RS485 serial port on the main board. The use of this serial port and specifications are shown in the Table 4.4 and its pin configuration is shown in Table 4.5. RS485 serial port is named as Int 3 on the main board.
  • Page 26 Figure 4.16 - HUB connection The PC connection cabling will be done via cross-over cable as shown below. IP address blocks and gateway address of FT-112 and PC should be the same in cross connection. FT-112 User Manual Rev. 2.0.0, June 2022...
  • Page 27 Connect the shield to the reference ground or shield pin of the power connector. Warning: Disconnect FLINTEC set up software before Ethernet interfacing. Step 10: USB port The use of the on-board USB 2.0 and its specifications are shown in Table .Table 4.8 You need the mini-...
  • Page 28: Cleaning

    Safety Notice: Disconnect the instrument from power source before cleaning. Be sure to Cover any open glands. FT-112 instrument is designed for use in wet, hygenic and harsh environment. To maintain the instrument, never use harsh abrasive cleaners or solvents. Wipe the instrument with a slightly damp, soft cloth using warm soapy water or mild detergent.
  • Page 29: Functions

    4. Read the weighing result. If the loads are out of the indication range the below prompts are displayed. Below the negative indication limit Over the positive indication limit FT-112 User Manual Rev. 2.0.0, June 2022 Page 28 of 180...
  • Page 30: Advanced Functions

    By programmed a key for Unit change, switching the displayed weight units from metric to imperial or vice- versa is possible. Unit change is possible between kg and lb, and between g and oz. Refer to sub-block 24-, page 55. FT-112 User Manual Rev. 2.0.0, June 2022 Page 29 of 180...
  • Page 31: Dynamic Weighing

    2. Place the container on the scale. 3. Press key for more than 2 seconds in basic weighing. The [ MEMORY ] message will appear on the display. FT-112 User Manual Rev. 2.0.0, June 2022 Page 30 of 180...
  • Page 32 Totalization FT-112 can be used for horizontal or vertical totalization operations. The vertical totalizing is used to totalize materials weighed into the same container. The horizontal totalization is used for weighing materials into separate containers or for totalizing the sequential weighing. Totalization weighing is limited to 99 items.
  • Page 33 Max, Min and Range of totalization for online inspection of the weighing terminal. Parameter 16A should be Totalization of Piece Counting Totalization can be done in piece counting. The FT-112 has two totalization memories which totalize in weighing and totalize in counting. Each totalization feature can be activated in the related operation e.g.
  • Page 34: Grand Total

    2. Press numeric keys to enter the time and press key to confirm 3. Press key until [ SAVE : YES ] prompt appears 4. Press key to save or press to operation without saving. FT-112 User Manual Rev. 2.0.0, June 2022 Page 33 of 180...
  • Page 35: Tilt Switch

    ID device APPLICATION: FT-112 can be connected to the ID device like bar code reader, card reader, RFID device etc. to read identification data, specific tare value, APW value etc. RELATED PARAMETERS: Sub-block 18- . You may enter the alphanumeric data from ID device instead of keypad. The ID device can be connected to RS232C and RS485 interface.
  • Page 36: Backup And Restore (With Sd Card)

    To back up FT-112 (D), use an SD card with 16Gb maximum and formatted as FAT32. For IMPORTANT NOTE Set-up and calibration data of the FT-112 (D) can be copied to an SD card to back up the instrument. After restoring this data to the instrument, you may go on operation without entering any data.
  • Page 37: Alibi Memory

    The weighing data in the alibi memory is indicated on the display Press key to print this record and the previous nine weighings Press key 4 times to return to normal operation FT-112 User Manual Rev. 2.0.0, June 2022 Page 36 of 180...
  • Page 38 The empty fields are indicated as [ ------- ] and transferred as [ NO RECORD ]; The corrupted records are indicated as [ Error ] and transferred as [ CORRUPTED ]. FT-112 User Manual Rev. 2.0.0, June 2022 Page 37 of 180...
  • Page 39: Programming And Calibration

    RELATED PARAMETERS: Sub-block 26- . 6.1.1 Keylock FT-112 has the ability to lock the keys to avoid unauthorized scale use. The key(s) which need to be locked can be programmed in the setup at sub-block 34- and the parameter 261.
  • Page 40: User Password

    Enter your 4 digit passport by pressing keys sequentially. [PASSWORD] (Default is 1111) [**** Press key. You entered to the programming main menu and the first main block [1 [1 INTERFACE ] INTERFACE ] prompt appears. FT-112 User Manual Rev. 2.0.0, June 2022 Page 39 of 180...
  • Page 41: Fast Access To The Frequently Used Parameter Blocks

    [ WAIT ] weighing mode. WARNING change before using your scale for trade. FT-112 User Manual Rev. 2.0.0, June 2022 Page 40 of 180...
  • Page 42: Programming And Parameters

    6.5 Programming and Parameters FT-112 weighing terminal is programmed in seven main blocks These are serial interface, configuration, application, scale, calibration, metrology and service. The main blocks in the programming menu are displayed as [1-- INTERFACE ] and sub-blocks are displayed as [11- RS232C-1 ].
  • Page 43 Modbus RTU High-Low format MBLH Modbus RTU Low-High format Press key to select output format different from Flintec continuous data format while the selection is CONT in the information display. Available functions are shown on the weight display after pressing key sequentially.
  • Page 44 Modbus RTU High-Low format MBLH Modbus RTU Low-High format Press key to select an output format different from Flintec continuous data format while the selection is CONT in the information display. Available functions are shown on the weight display after pressing key sequentially.
  • Page 45 Modbus RTU High-Low format MBLH Modbus RTU Low-High format Press key to select an output format different from Flintec continuous data format while the selection is CONT in the information display. Available functions are shown on the weight display after pressing key sequentially.
  • Page 46 High speed continuous data output BSI format for PC, PLC interface Press key to select an output format different from Flintec continuous data format while the selection is CONT in the information display. Available functions are shown on the weight display after pressing key sequentially.
  • Page 47 Modbus TCP High-Low format MBLH Modbus TCP Low-High format Press key to select an output format different from Flintec continuous data format while the selection is CONT in the information display. Available functions are shown on the weight display after pressing key sequentially.
  • Page 48 Flintec LM2 ( BX1 par.000=6 ) LLINE2 Commonly used by Tunaylar. : 250 IP address. Default is 192.168.016.250 ADDRESS : 00 Address of the port 00 means data format without address. SUBMASK : 000 Subnet mask address. Default is 255.255.255.000...
  • Page 49 Print ID2 data Print ID2 name and data S.NAME : NO Scale name printing on printout. Disable Enable STATIST : NO Statistical results print with totalization printout. Disable Enable FT-112 User Manual Rev. 2.0.0, June 2022 Page 48 of 180...
  • Page 50 LENGTH : 32 Data length. The identification data or specific tare length which is located after stx and prefix in the string. : NO Automatic save the data AUTOSAVE FT-112 User Manual Rev. 2.0.0, June 2022 Page 49 of 180...
  • Page 51 Press key to go to the sub-block 11- or press key to go to the next sub-block. 191 FORMAT INTG ] Data format of the Profinet FT-112 User Manual Rev. 2.0.0, June 2022 Page 50 of 180...
  • Page 52 194 SUB MASK 000 ] Subnet mask address of Ethernet port. Default is 255.255.255.000 195 GATEWAY 253 ] Gateway address. Default is 192.168.16.253 19A MAC ADR MAC address AA:BB:CC:DD:EE:FF FT-112 User Manual Rev. 2.0.0, June 2022 Page 51 of 180...
  • Page 53 INTG ] Data format of the Powerlink INTG Signed 32 bit integer, no decimal point implied. FLOA 32 bit float, decimal point implied. 192 ADDRESS 001 ] Node address FT-112 User Manual Rev. 2.0.0, June 2022 Page 52 of 180...
  • Page 54 GTOT Grand Total Active APW value. NAME Active APW value, Scale name Note: The par 221 is set to NO, if this parameter isn't programmed NO, TARE or GROSS. FT-112 User Manual Rev. 2.0.0, June 2022 Page 53 of 180...
  • Page 55 Low filter MEDI Medium filter HIGH High filter VHIG Very high filter. Slowest and the most stable weighing. [ 236 LANGUAGE : ENG Language. English Deutsch Français Espagnol Türkçe FT-112 User Manual Rev. 2.0.0, June 2022 Page 54 of 180...
  • Page 56: Keys Function

    Temp. Gross in Net GTOT Grand total RPRN Reprint DYNA Dynamic weighing start Scale change UNIT Unit change (only FT-112) [ 242 : G/N The function of F2 key Disable Count with APW ID2 key HIGH High resolution Setpoint/ SmartAPP limit value entry...
  • Page 57 To lock keys and to erase grand total. Page 39 [ 262 USER : 1111 Set up password. NEW - CONFIRM Page 39 [ 263 SERVICE : 1111 Set up password. NEW - CONFIRM FT-112 User Manual Rev. 2.0.0, June 2022 Page 56 of 180...
  • Page 58 Change if the scale is stable. [ 317 ACCUSTI : OKAY Acoustic warning Disabled OKAY One beep if okay OVER One beep if over CROS One beep with every limit value crossover. FT-112 User Manual Rev. 2.0.0, June 2022 Page 57 of 180...
  • Page 59 Page 30 331 OPERATE NO ] Operation type Disable Dynamic weighing starts after pressing the key if W >50e. SAUT Dynamic weighing starts automatically if W >50e. FT-112 User Manual Rev. 2.0.0, June 2022 Page 58 of 180...
  • Page 60 Do not lock LOCK Lock 34A ZEROING USE ] Zeroing key locking Do not lock LOCK Lock 34B ENTER USE ] Enter key locking Do not lock LOCK Lock FT-112 User Manual Rev. 2.0.0, June 2022 Page 59 of 180...
  • Page 61 The functions of Input 3 are the same as for Input 1 Page 80 354 INPUT 4 NO ] Input 4 The functions of Input 4 are the same as for Input 1 FT-112 User Manual Rev. 2.0.0, June 2022 Page 60 of 180...
  • Page 62: Identification Data

    ID data is displayed after displaying the identification name for 2 seconds. Page 78 372 ID1NAME ID 1 ] Identification name entry of ID1 key Maximum 16 characters. Default is ID 1. FT-112 User Manual Rev. 2.0.0, June 2022 Page 61 of 180...
  • Page 63 Linked memories to ID2 memory Not any linked memory. APW memory. Set memory PT memory. SET and PT memories. APW and PT memories. APW and SET memories. APW and SET and PT memories. FT-112 User Manual Rev. 2.0.0, June 2022 Page 62 of 180...
  • Page 64 Temporary indication with key (Default) TOGG Toggle. Start and end high resolution by pressing key in sequence. ALWA Always high resolution Power on Page 513 PWR ZERO NO ] zero. FT-112 User Manual Rev. 2.0.0, June 2022 Page 63 of 180...
  • Page 65 MINWEIGHT XXX.XXX. Default is 20d. Tilt switch to prevent incorrect weighing results in mobile TILT : NO scales. (Digital Input-4) Not used. OPEN Normally open contact. CLOS Normally closed contact. FT-112 User Manual Rev. 2.0.0, June 2022 Page 64 of 180...
  • Page 66 Enter the quantity of DLC used in the scale. The quantity can be entered between 1 and 16. [ 533 ADDRESSING Addressing of digital load cells Enter serial number after press key. FT-112 User Manual Rev. 2.0.0, June 2022 Page 65 of 180...
  • Page 67 [ 544 SET TO 1 NO ] M Temporarily set shift constants to 1 Normal operation (entered shift constants are used). Test mode (shift constants are equal to 1). FT-112 User Manual Rev. 2.0.0, June 2022 Page 66 of 180...
  • Page 68 The load weight used in the calibration is indicated here. 632 ZERO COEFFIC This coefficient determines the zero point of the scale. 633 GAIN COEFFIC This coefficient is related to the gain factor of the scale. FT-112 User Manual Rev. 2.0.0, June 2022 Page 67 of 180...
  • Page 69 This non-resettable and protected counter displays number of [ 822 CONFIG COUNT times the instrument was accessed. Count number increases with every exit from set-up mode. [ 823 NEXT VERIFIC Date of the next verification FT-112 User Manual Rev. 2.0.0, June 2022 Page 68 of 180...
  • Page 70: Hardware Test

    The last 20 under errors listed in this parameter. 923 ERROR LOGS The last 20 errors listed in this parameter. 924 ENTRY LOGS The last 20 Service/User entry listed in this parameter. FT-112 User Manual Rev. 2.0.0, June 2022 Page 69 of 180...
  • Page 71 971 INSTRUMENT XX.XX 972 OPTION XX.XX 973 UPGRADE Firmware upgrade Call Flintec service or dealer to upgrade. 974 DLC BOARD XX.XX (FT-112D only)) Call Flintec service or dealer to upgrade. DEFAULTS LOADING Press key or key again to enter this menu.
  • Page 72: Calibration

    Then continue with the following: Calibration involves emptying the scale then placing a known test weight on an empty platform and allowing the FT-112 indicator to capture values for zero and scale. Calibration is performed as follows: Press key at the [ 611 TEST WEIGHT ] prompt to start the calibration.
  • Page 73: Zero And Span Adjustments

    If the value of the test weights that will be used is different from the value shown on the display, type in the new value via tare and zero keys. A minimum of 20% of scale capacity is necessary for calibration; FLINTEC recommends 50 to 100%. A calibration error will result if insufficient weight is used.
  • Page 74: Ecal Electronic Calibration

    2. Scale adjustment cancels the eCal performed before. 3. Gravity adjustment cannot be done after eCal. This parameter lets you perform calibration without using any test weights. FT-112 A/D coefficients are adjusted in production for increasing eCal accuracy. The calibration coefficients are calculated by scale capacity, total load cell capacity, load cell full scale output and estimated dead load.
  • Page 75: Gravity Adjustment

    Note these coefficients to use them in case of calibration lost. Changing them slightly improves the scale accuracy without recalibration. Entering these values to another indicator may cause slightly reducing the weighing accuracy due to offset differences between two analogue digital circuits. FT-112 User Manual Rev. 2.0.0, June 2022 Page 74 of 180...
  • Page 76: Digital Load Cells (Dlc)

    8. Press key to access to Shift adjustment block or press key until [ SAVE : YES ] prompt appears on the display and press key to save the changes. FT-112 User Manual Rev. 2.0.0, June 2022 Page 75 of 180...
  • Page 77 2. It will be [ 544 SET TO 1 : NO ], press key until [ SAVE : YES ] prompt seen on the display. 3. Press key to save the changes into the memory. FT-112 User Manual Rev. 2.0.0, June 2022 Page 76 of 180...
  • Page 78: Working With Two Scales (Ft-112)

    RELATED PARAMETERS: Main block 5-- . Up to 2 weighing scales can be connected to the FT-112. Depending on the second scale board in the instrument and set up, 2 scales can be used in parallel or serial with summing scale feature of the weighing terminal.
  • Page 79: Identification Data Record (Id1, Id2)

    RELATED PARAMETERS: Sub-block 37- . FT-112 indicator has 2 identification keys, ID1 and ID2, positioned under the display for storing identification data. Each identification key has an alphanumeric identification name and data. The identification data can be saved in the ID1 and ID2 memories. Each has 500 pieces, 32 character identification data record size.
  • Page 80 ID data entry from barcode reader or ID device RELEATED PARAMETERS : Sub-block 18- and parameters 111, 121 and 131. Press the identification key Read the barcode. Confirm with key. FT-112 User Manual Rev. 2.0.0, June 2022 Page 79 of 180...
  • Page 81: Digital Inputs -Outputs / Setpoints And Limits

    10.1 Electrical Connection 10.1.1 Digital Inputs FT-112 digital inputs which are independently programmable for zeroing, taring, clear, print, key lock and as a fieldbus input port in basic weighing usage of the weighing terminal. If the instrument is programmed for any SmartAPP application, the inputs are configured for this usage.
  • Page 82 Refer to related fieldbus command table to receive the status of inputs. This usage is independent from the weighing process of the instrument. FT-112 User Manual Rev. 2.0.0, June 2022 Page 81 of 180...
  • Page 83 S ANE Free setpoint of absolute net weight The digital output is activated with comparing the set point value and absolute net weight value as seen below. FT-112 User Manual Rev. 2.0.0, June 2022 Page 82 of 180...
  • Page 84 SP GRO - Free setpoint of gross weight (previously SP G) The digital output is activated with comparing the set point value and gross weight value as indicated below. FT-112 User Manual Rev. 2.0.0, June 2022 Page 83 of 180...
  • Page 85 Non-used digital outputs can be programmed freely. For example, if SP5 is not needed to control process it can be set up to zero range to get empty signal. FT-112 User Manual Rev. 2.0.0, June 2022 Page 84 of 180...
  • Page 86 The digital output(s) can be controlled from PLC as a Remote output if the instrument is equipped with any fieldbus option. Refer to related fieldbus command table to activate or deactivate the outputs. This usage is independent from the weighing process of the instrument. FT-112 User Manual Rev. 2.0.0, June 2022 Page 85 of 180...
  • Page 87 For example, the Output 5 of Filling is not used by the Filling application software and it can be used as zero range output to check the scale unloading. Refer to SmartAPP section, page 88, for usage of digital inputs and outputs details. FT-112 User Manual Rev. 2.0.0, June 2022 Page 86 of 180...
  • Page 88: Basic Weighing

    (SPI), free setpoint of gross weight (SPG) or control output (SPC). IMPORTANT NOTE: The names for items feature is valid for FT-112 with the firmware v01.09 / FT-112D v01.07 and higher. 10.3 Application Weighing This weighing terminal may be equipped with 5 programmable setpoints to use them in basic weighing or in an application.
  • Page 89: Smartapp

    Digital inputs and outputs may change their status immediately or if the weight is stable. Refer to page 58. FT-112 User Manual Rev. 2.0.0, June 2022 Page 88 of 180...
  • Page 90: Standard Applications

    242. RELATED PARAMETERS: Parameters 241 and 242. FT-112 indicator has several powerful features in counting/weighing as described in this section. Use the key for piece counting, and key for APW (average piece weight) entry (page 55). If APW entry will be done or APW memory will be used.
  • Page 91 Display will show the material quantity on the scale. If you want to accumulate the sequential counting, press key (refer to page 31, 32) To return to the weighing mode, press key. FT-112 User Manual Rev. 2.0.0, June 2022 Page 90 of 180...
  • Page 92 Apply sampling to Scale-1 for calculated APW as described above. Select Scale-2 for counting item and place the item on the platform after zeroing. Read the quantity of the items on the display. FT-112 User Manual Rev. 2.0.0, June 2022 Page 91 of 180...
  • Page 93 [APW 123: 6.465434 ]. Enter new APW value by pressing numeric keys. Press key to record the APW value in this memory. Press key to exit piece counting. FT-112 User Manual Rev. 2.0.0, June 2022 Page 92 of 180...
  • Page 94 To delete the total, press key while the total is displayed. Confirm [ Delete ? ] prompt by pressing key or press key to return to the operation without deleting the total. FT-112 User Manual Rev. 2.0.0, June 2022 Page 93 of 180...
  • Page 95: Classifying

    The scale is empty if the weight is in the Empty range. SmartAPP Bar Figure 12.1 - Timing diagram of automatic classifying operation. FT-112 User Manual Rev. 2.0.0, June 2022 Page 94 of 180...
  • Page 96 : 100,0 ] prompt appears on the display. Enter a new value with numeric keys. Press the key to go to the following memory after save, or press key to return to the operation without saving. FT-112 User Manual Rev. 2.0.0, June 2022 Page 95 of 180...
  • Page 97 Reset Input-3 Refer to parameter 353 Input-4 Refer to parameter 354 Output-1 Output-2 Output-3 Output-4 + Tolerance Output-5 + + Tolerance Table 12.1- Digital inputs and outputs of Classifying FT-112 User Manual Rev. 2.0.0, June 2022 Page 96 of 180...
  • Page 98: Checkweighing

    The operation starts by pressing the function key or by digital input. The scale is empty if the weight is in the Empty range. The checkweighing operation is shown in diagram below SmartAPP Bar Figure 12.3 - Timing diagram of checkweighing operation. FT-112 User Manual Rev. 2.0.0, June 2022 Page 97 of 180...
  • Page 99 Enter the memory code of the product by pressing the numeric keys and press key. The selected product limits are loaded for usage after displaying values. Or press key to exit without selecting the product from memory. FT-112 User Manual Rev. 2.0.0, June 2022 Page 98 of 180...
  • Page 100 Refer to parameter 354 Output-1 (light) Output-2 Output-3 + Tolerance (heavy) Output-4 Refer to parameter 364 Output-5 Refer to parameter 365 Table 12.2 - Digital inputs and outputs of Checkweighing. FT-112 User Manual Rev. 2.0.0, June 2022 Page 99 of 180...
  • Page 101: Filling

    Filling is used for weighing of materials into a container. The scale accepts the load if the gross weight is greater than the empty range. The Filling operation is shown in the diagram below. SmartAPP Bar Figure 12.5 - Timing diagram of filling operation. FT-112 User Manual Rev. 2.0.0, June 2022 Page 100 of 180...
  • Page 102 The [ COARSE : 1,80 ] prompt appears on the display. Enter a new value with numeric keys. Press the key to save or press key to leave without saving. FT-112 User Manual Rev. 2.0.0, June 2022 Page 101 of 180...
  • Page 103 Refer to parameter 315, page 57 to set up the SmartAPP. Unloaded pan Coarse & Fine feed Fine feed End of filling Figure 12.6 - Weight display and toolbar at checkweighing. FT-112 User Manual Rev. 2.0.0, June 2022 Page 102 of 180...
  • Page 104: Packing

    3. The terminal automatically tares the load with a specific tare 4. Put the product into the container. 5. The display colour changes to green if the weight is in tolerance. 6. Remove the container for the next weighing. FT-112 User Manual Rev. 2.0.0, June 2022 Page 103 of 180...
  • Page 105 The operation continues from item 4 to item 6 until the last container is filled. 8. Remove the case. The scale returns to gross weighing. Figure 12.7 - Timing diagram of packing operation with autotaring. FT-112 User Manual Rev. 2.0.0, June 2022 Page 104 of 180...
  • Page 106 3. Enter the memory code of the product by pressing the numerical keys and press key. 4. The selected product limits are loaded for usage after displaying values. 5. Or press key to exit without selecting the product from memory. FT-112 User Manual Rev. 2.0.0, June 2022 Page 105 of 180...
  • Page 107 Refer to parameter 354 Output-1 Output-2 Output-3 + Tolerance ( heavier ) Output-4 Refer to parameter 364 Output-5 Refer to parameter 365 Table 12-4 - Digital inputs and outputs of Packing. FT-112 User Manual Rev. 2.0.0, June 2022 Page 106 of 180...
  • Page 108: Rs232 And Rs485 Data Outputs

    If you transmit the ASCII codes: P(print), Z(zero), T(tare) or C(clear) letters to the serial port of FT-112; the indicator will act as if the related key is pressed.
  • Page 109: Fast Continuous Data Output

    12.02.2016 14:47 CN: 71 G: 3.007kg T: 1.001kg N: 2.006kg *ALB: DATE TIME GROSS PT or Name Data Name Data TARE Max. 16 Max. 32 Max. 16 Max. 32 FT-112 User Manual Rev. 2.0.0, June 2022 Page 108 of 180...
  • Page 110: Multi Line

    3.097 kg Gross/Tare/Net weights * Thank you * * Thank you * Footer 26F1 Includes only Gross or 26F2 Includes Gross or Gross\ Net weight value Tare\Net weight values FT-112 User Manual Rev. 2.0.0, June 2022 Page 109 of 180...
  • Page 111: Epl Format

    Figure 13.1- Sample of the label printout of FT-112 which is designed in EPL format. If the label design can be saved into the printer, the default of EPL format of FT-112 can be transferred to the printer to print a designed label. The default of EPL format is: FT-112 User Manual Rev.
  • Page 112: Bsi Data Structure For Dialog With Pc And Plc

    Connecting the FT-112 to your computer or with your PLC which does not have any fieldbus interface, using BSI commands will help to equip your system with additional FLINTEC scales without having to change your application programs.
  • Page 113 Read set points [ADR][R][SP No][L] [ADR][R][STATUS][SIGN][SP VALUE] Read Status [ADR][S] [ADR][S][STATUS-1][STATUS-2] [STATUS-3] Tare [ADR][T] [ADR][T][STATUS] Read digital inputs [ADR][U] [ADR][U][STATUS][Inputs] Read digital outputs [ADR][V] [ADR][V][STATUS][Outputs] Set/Reset digital outputs [ADR][W][Outputs] [ADR][W][STATUS] FT-112 User Manual Rev. 2.0.0, June 2022 Page 112 of 180...
  • Page 114 X=3; L. green X=9; Red X=4; Green Checksum Calculation: CHK is transmitted as two ASCII characters calculated with the Checksum formulation. Checksum = 0 (SUM of all response data before CHK) FT-112 User Manual Rev. 2.0.0, June 2022 Page 113 of 180...
  • Page 115: Bsi-Base Commands

    : The last printed values are transmitted immediately after receiving the command. Single line data format can be change due to its configuration. Refer to section 13.3 and sub-block. FT-112 User Manual Rev. 2.0.0, June 2022 Page 114 of 180...
  • Page 116 (Weight is stable and 123.4) 01ID+000123.4 (Weight is dynamic and 123.4) 01I+ (Overload) Comments: Indicated weight value (stable or dynamic) is transmitted immediately. The weight value may be in gross or net. FT-112 User Manual Rev. 2.0.0, June 2022 Page 115 of 180...
  • Page 117 SP VALUE data is 8-byte ASCII char with dot and non-significant zeros on the left. Read Status Command [ADR][S] Response [ADR][S][STATUS-1][STATUS-2][STATUS-3] Example Command : 01S Response : 01SSGI (Stable, Gross, In Range) 01SDGL (Dynamic, Gross, Low voltage error) FT-112 User Manual Rev. 2.0.0, June 2022 Page 116 of 180...
  • Page 118 (All 8 outputs are active) 01VN (Could not read outputs) Comments: Data length change according to number of digital outputs. Outputs are implemented to ASCII char of 4-bit OUTPUTS Bit wise ASCII FT-112 User Manual Rev. 2.0.0, June 2022 Page 117 of 180...
  • Page 119 Weight must be in zeroing range for all operating modes. Status must be stable for 2 seconds. If so, Ack is sent. If unstable during time out delay, Nack is sent. FT-112 User Manual Rev. 2.0.0, June 2022 Page 118 of 180...
  • Page 120: Modbus Rtu

    13.6 Modbus RTU FT-112 controller has a Modbus RTU interface over RS485 / RS232C serial port. This interface can be programmed to High-Low or Low- the difference in these data formats and some companies using these formats below. Two types are available as: 13.6.1 Modbus RTU and TCP/IP Data Structure...
  • Page 121 SmartAPP Start SmartAPP Reset Switch to 1.Scale Switch to 2.Scale Switch to Summing Scale Switch to Counting mode Switch to Weighing mode None Commands 40027 status Command is successfully. FT-112 User Manual Rev. 2.0.0, June 2022 Page 120 of 180...
  • Page 122 Very High Disable ± 2% ± 2%LK 40131 Power on zero ± %10 + %15, - %5 ± %20 Disable ± 2% 40133 Zeroing Range ± 3% ± 20% FT-112 User Manual Rev. 2.0.0, June 2022 Page 121 of 180...
  • Page 123 40159 Decimal point-1 XXXXXX XXXXX.X XXXX.XX XXX.XXX Description 40161 Increment-1 40163 MAX-2 40165 Decimal point-2 40167 Increment-2 40169 MAX-3 40171 Decimal point-3 40173 Increment-3 40175 Limit of Indication Description FT-112 User Manual Rev. 2.0.0, June 2022 Page 122 of 180...
  • Page 124 Apply the coefficients of eCal 23205 (first, load 40189, 40191 and 40193) 40187 Span Calibration Value 40189 Total Load Cell capacity for eCal (FT-112 only) eCal 40191 Average mV/V value for eCal (FT-112 only) Coefficients 40193 Dead load value for eCal...
  • Page 125 Refer to parameter [322] on page 58 40271 Filling type GROS 40273 Taring delay at filling Refer to parameter [323] on page 58 Refer to parameter [324] on page 58 40275 Totalization type HORI VERT FT-112 User Manual Rev. 2.0.0, June 2022 Page 124 of 180...
  • Page 126 For hardware connection details, please refer to the related hardware descriptions in this manual. Exception codes: 1: Function code is not supported. 2: Out of beginning and ending address range. 3: Invalid value entrance or wrong byte number. 4: Operation error. FT-112 User Manual Rev. 2.0.0, June 2022 Page 125 of 180...
  • Page 127 (Input-2 is active) Read digital outputs 01,03,00,2A,00,02,E5,C3 Answer of digital outputs 01,03,04,00,00,00,04,FB,F0 (Output-3 is Active) Read Setpoint-1 01,03,00,2C,00,02,05,C2 Answer of Setpoint-1 01,03,04,00,00,03,E8,FA,8D Load Set point 1 = 5000 01,10,00,2C,00,02,04,00,00,13,88,FC,B4 FT-112 User Manual Rev. 2.0.0, June 2022 Page 126 of 180...
  • Page 128: Ethernet Tcp/Ip

    13.7 Ethernet TCP/IP Ethernet output of FT-112 is programmable in BSI command set, Continuous data output, Fast continuous data output, Modbus TCP/IP High-Low, Modbus TCP/IP Low-High. The first three data structures can be found in the related sections indicated in the table below.
  • Page 129: Modbus Tcp Data Structure

    : 01 to 255 Programme the Ethernet parameter settings as defined on Please find Modbus information in the web site of http://www.modbus.org Modbus TCP/IP Command Table see page 119 FT-112 User Manual Rev. 2.0.0, June 2022 Page 128 of 180...
  • Page 130: Optional Boards

    Install the option board to the J5 and J3 connectors carefully. Mount the M3 x 6 screw to fix option board to the spacer. Install cables to the option board as described in the related sections. FT-112 User Manual Rev. 2.0.0, June 2022 Page 129 of 180...
  • Page 131: Installation Of Sd Card And Alibi Memory Card

    14.1 Installation of SD Card and Alibi Memory Card Some features of the FT-112 need to be inserted into the SD card. SD1 (Aliby) is located between the load cell terminal and metal box of the analog digital converter. SD2 is located close to the USB connector on the main board.
  • Page 132: Digital Inputs And Outputs

    14.2.1 Digital Inputs FT-112 digital inputs which are independently programmable for zeroing, taring, clear, print, key lock and as a fieldbus input port in basic weighing usage of the weighing terminal. If the instrument is programmed for any SmartAPP application, the inputs are configured for this usage.
  • Page 133: Digital Outputs

    The analogue output cable should be shielded. Connect the shield to the protective earth as described in the installation section. FT-112 is programmable to 4 20 mA, 0 20 mA, 0 5 V or 0 10 V analogue output types. Analog output is automatically adjusted to the weighing range after the calibration.
  • Page 134: Profibus Dp

    45.45 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, instance exists. After programming Profibus related parameters of the indicator, you can communicate with the instrument. The GSD file is available on www.flintec.com There are LEDs near the Profibus connector which are Ref. Definition Ref.
  • Page 135: Electrical Connection

    Refer to parameter [ 191 ]. 14.4.3 GSD Configuration Profibus data consist of 2 Input-double-words and 2 Output-double-words like shown in the GSD configuration below. Figure 14.3 - GSD Configuration FT-112 User Manual Rev. 2.0.0, June 2022 Page 134 of 180...
  • Page 136: Profibus Data Structure

    GSD Configuration Description Input 2 words Dword (FT-112 Output to PLC Input) Input 2 words Dword (FT-112 Output to PLC Input) Output 2 words Dword (PLC Output to FT-112 Input) Output 2 words Dword (PLC Output to FT-112 Input) 14.4.4 Profibus Data Structure For the Date Structure for Profibus see Apendix 2, page 155.
  • Page 137: Profinet

    If seen again, change the board. In the case of LED warning, check cabling, configuration, IP address and device name. Power off the instrument and reenergize the instrument 30 seconds later. FT-112 User Manual Rev. 2.0.0, June 2022 Page 136 of 180...
  • Page 138: Electrical Connection

    The PC connection cabling will be done via cross-over cable as shown below. IP address blocks and gateway address of weighing terminal and PC should be the same in cross-over connection. Figure 14.6 - Cross PC connection FT-112 User Manual Rev. 2.0.0, June 2022 Page 137 of 180...
  • Page 139: Data Format

    Profinet parameters can be adjusted by keys in programming mode. Refer to parameter block [ 19- ]. Additionally, Profinet parameters set up is done by EtherX PC software over Local Network Area or by IndFace2x. Both software versions are available on internet www.flintec.com. Note parameter 196.
  • Page 140: Profinet Data Structure

    14.6 CANopen Please set the related parameters to enable communication with the indicator via CANopen network. The EDS file is available on www.flintec.com. Automatically detected and supported baud rates are 10 kbps, 50 kbps, 100 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps, 1 Mbps, Autobaud (default).
  • Page 141: Electrical Connection

    Pin configuration of digital input and output connector is described in section 4.3.17/18. 14.6.2 Data Format Data format of weight value can be programmed for Floating point (IEEE 754) or Integer. Refer to parameter [ 191 ]. FT-112 User Manual Rev. 2.0.0, June 2022 Page 140 of 180...
  • Page 142: Eds Configuration

    Figure 14.9 - EDS Configuration EDS Configuration Description TxPDO 1 (4 words) Unsigned Long (FT-112 Output to PLC Input) RxPDO 1 (4 words) Unsigned Long (PLC Output to FT-112 Input) 14.6.4 CANopen Data Structure For the Date Structure for CANopen see Apendix 2, page 155 FT-112 User Manual Rev.
  • Page 143: Ethernet/Ip

    You may change the port, if there is any malfunction on port in usage. The EtherNet/IP interface supports 10/100Mbit, full or half duplex operation. The EDS file for two port EtherNet/IP is available on www.flintec.com There are announcement LEDs on the instrument to indicate the interface status as shown below.
  • Page 144: Electrical Connection

    The PC connection cabling will be done via cross-over cable as shown below. IP address blocks and gateway address of weighing terminal and PC should be the same in cross connection. Figure 14.12 - Cross PC connection FT-112 User Manual Rev. 2.0.0, June 2022 Page 143 of 180...
  • Page 145: Data Format

    EtherNet/IP parameters can be adjusted by keys in programming mode. Refer to parameter block [ 19- ]. Additionally, EtherNet/IP parameter set up is done by EtherX PC software over Local Network Area or by IndFace2x. Both softwares are available on www.flintec.com. Parameters...
  • Page 146: Ethernet/Ip Data Structure

    Figure 14.14 Configuration of module properties with EDS file Data Length Description Input 2 words Dword (FT-112 Output to PLC Input) Input 2 words Dword (FT-112 Output to PLC Input) Output 2 words Dword (PLC Output to FT-112 Input) Output 2 words Dword (PLC Output to FT-112 Input) 14.7.5 EtherNET/IP Data Structure...
  • Page 147: Ethercat

    2. Star connection. If you connect the instrument to your PLC via hub switch, you can use P1 port on the instrument. The EtherCAT interface supports 100Mbit, full duplex operation. ESI file for two ports EtherCAT is available on www.flintec.com. There are announcement LEDs on the instrument to indicate the interface status as shown below. Ref. Definition Ref.
  • Page 148: Electrical Connection

    Figure 14.17 - Cross PC connection 14.8.2 Data Format Data format of weight value can be programmed for Floating point (IEEE 754) or Integer. Refer to parameter [ 191 ]. FT-112 User Manual Rev. 2.0.0, June 2022 Page 147 of 180...
  • Page 149: Esi Configuration

    The ESI configuration for PLC programmers is shown in Figure 14.18. Figure 14.18 Configuration of module properties for Beckhoff Input/Output Definition Description FT-112 Output to PLC Input SubIndex 001 Dword ( DI TxPDO-Map FT-112 Output to PLC Input SubIndex 002...
  • Page 150: Cc-Link

    Station Number or Baud rate has changed since startup (flashing) In the case of red LED warning, check cabling, configuration, and station number. Power off the instrument and reenergize the instrument 30 seconds later. FT-112 User Manual Rev. 2.0.0, June 2022 Page 149 of 180...
  • Page 151: Electrical Connection

    Weighing terminal has one occupied station area on CC-Link network. The station type of weighing terminal must be The CC-Link configuration for PLC programmers is shown in Figure 14.20. Figure 14.20 Station information FT-112 User Manual Rev. 2.0.0, June 2022 Page 150 of 180...
  • Page 152: Cc-Link Data Structure

    Input/Output Definition Description FT-112 Output to PLC Input RWr0, RWr1 Dword Input ( Remote Register (RWr) FT-112 Output to PLC Input RWr2, RWr3 Dword Input ( Remote Input (RX) RX0 ~ RX31 Not used RWw0, RWw1 Dword Output ( PLC Output to FT-112 Input...
  • Page 153: Powerlink

    The port may be changed, if there is any malfunction on the port in use. The Powerlink interface is 100Mbit and half duplex. The XDD file for two ports Powerlink is available on www.flintec.com. There are announcement LEDs on the instrument to indicate the interface status as shown below.
  • Page 154: Electrical Connection

    Figure 14.22 - HUB connection 14.10.2 Data Format Data format of weight value can be programmed for Floating point (IEEE 754) or Integer. Refer to parameter [ 191 ]. FT-112 User Manual Rev. 2.0.0, June 2022 Page 153 of 180...
  • Page 155: Xdd Configuration

    The XDD configuration for PLC programmers is shown in Figure 14.23. Figure 14.23 Configuration of module properties with XDD file Data Length Description 1_Dword_Input_I2001_S01 Dword (FT-112 Output to PLC Input) 2_Dword_Input_I2001_S02 Dword (FT-112 Output to PLC Input) 1_Dword_Output_I2002_S01Out Dword (PLC Output to FT-112 Input)
  • Page 156: Appendix 1: Datas

    P.Tare Read command response modes of zero RWr3)* for Profibus, Profinet, EtherNET/IP, EtherCAT, Powerlink for CC-Link FT-112 Output to PLC Input 2 Dword Bit Number 2nd Dword Description Digital Outputs Output bit status (Active = 1) Digital Inputs Input bit status (Active = 1)
  • Page 157 ++High areMax 10100 Not used Empty Not used Empty 10101 Not used 11110 Expanded Commands List 11111 (Refer to Table 15.3) The command is applied successfully CMD Flag Toggles FT-112 User Manual Rev. 2.0.0, June 2022 Page 156 of 180...
  • Page 158 ALL Status (always 32 bit integer) Dword of PLC Output to FT-112 Input. Bit Number 1st Dword (input) Description None No decimal point None Decimal point is X.X None Place of decimal point Decimal point is X.XX None Decimal point is X.XXX None Decimal point is X.XXXX...
  • Page 159 Calibration Status (always 32 bit integer) Dword of PLC Output to FT-112 Input Bit Number 1st Dword (input) Description Not in use No Error The Calibration DIP switch is not in position. - Check the calibration DIP switch. No Error...
  • Page 160 Command List Read Data Selection RWw3)* for Profibus, Profinet, EtherNET/IP, EtherCAT for CC-Link PLC Output to FT-112 Input 2 Dword Bit No. 2nd Dword descriptions Set / Reset digital outputs Select an item form the Expanded Commands List (Refer to Table 15.3)
  • Page 161 From first to second unit 00000101 Unit change From second to first unit Enable 00000110 Key lock (1) (2) Disable Dynamic reset Dynamic 00000111 operation Dynamic start 00001000 Totalization None FT-112 User Manual Rev. 2.0.0, June 2022 Page 160 of 180...
  • Page 162 Tare only at gross Preset tare Preset tare at gross ± 0,3d ± 0,5d ± 1d Stability 01000101 Detection ± 2d (1) (2) Range ± 3d ± 4d Disable FT-112 User Manual Rev. 2.0.0, June 2022 Page 161 of 180...
  • Page 163 01100100 Refer to par. RBAY 315 page 57 YABR CHANGE (1) (2) STAB 01100101 Refer to par. IMME 316 page 57 (1) (2) ACOUSTI 01100110 Refer to par. OKAY FT-112 User Manual Rev. 2.0.0, June 2022 Page 162 of 180...
  • Page 164 Table 15.3 - Expanded Command List (1) Write this command after writing values to 1 Dword (Output) then apply this command with New CMD. (2) To access the related value, read 1 Dword (Input). FT-112 User Manual Rev. 2.0.0, June 2022 Page 163 of 180...
  • Page 165 Programming steps of frequent use Reading a weight value: Check the B FT-112 Output to PLC Input 2 2. If there is no error, read a weight value (gross, net or tare). Zero Calibration procedure: Check the Bit-0 of Calibration Status. it should be '1'(set) to start adjustment.
  • Page 166: Appendix 2: Data Structure Canopen

    Read command response modes of zero (T_UL1) By default, Actual weight value is represented. To represent other weight or FT-112 Output to PLC Input 2 Dword Bit Number TxPDO 1 (T_UL1) Description Digital Outputs Output bit status (Active = 1)
  • Page 167 10101 Not used 11110 Use the Expanded Command list 11111 (Refer to Table 16.3) The command is applied successfully CMD Flag Toggles By default, Actual weight value is represented. FT-112 User Manual Rev. 2.0.0, June 2022 Page 166 of 180...
  • Page 168 ALL Status (always a 32bit integer) to FT-112 Input. Bit Number Low Dword of TxPDO 1(T_UL1) Description None No decimal point None Decimal point is X.X None Place of decimal point Decimal point is X.XX None Decimal point is X.XXX None Decimal point is X.XXXX...
  • Page 169 Calibration Status (always a 32bit integer) Output to FT-112 Input. Bit Number Low Dword of TxPDO 1(T_UL1) Description Not in use No Error The Calibration DIP switch is not in - Check the calibration DIP switch. No Error Scale unstable...
  • Page 170 Not in use Command List Read Data Selection (R_UL1) B33-B37 bits defines the usage of this Dword. PLC Output to FT-112 Input RxPDO 1 (R_UL1) RxPDO 1 (R_UL1) descriptions Number Set / Reset digital outputs Table 16.3 Expanded Commands List (Refer to...
  • Page 171 Toggle D33-D37 bits defines the usage of this Dword. B31-B0 (1) Write this command after writing values to Low Dword of RxPDO then apply this command with New CMD. FT-112 User Manual Rev. 2.0.0, June 2022 Page 170 of 180...
  • Page 172 (1) (2) Refer to par. 332 page 59 00111111 Very Low 01000000 Filter (1) (2) Medium High Very High Disable 01000001 Power on zero (1) (2) ± %2 ± %2LK FT-112 User Manual Rev. 2.0.0, June 2022 Page 171 of 180...
  • Page 173 XXX.XXX 01001011 Increment-1 (1) (2) (1) (2) 01001100 Capacity-2 (1) (2) 01001101 Decimalpoint-2 (1) (2) 01001110 Increment-2 (1) (2) 01001111 Capacity-3 (1) (2) 01010000 Decimalpoint-3 (1) (2) 01010001 Increment-3 FT-112 User Manual Rev. 2.0.0, June 2022 Page 172 of 180...
  • Page 174 (1) Write this command after writing values to Low Dword of RxPDO then apply this command with New CMD. (2) To access the related value, read Low Dword of TxPDO. FT-112 User Manual Rev. 2.0.0, June 2022 Page 173 of 180...
  • Page 175 4. The Bit-0 of Calibration Status changes to '1'(set) at the end of the Span calibration. 5. If the Bit-3~Bit-10 of Calibration Status is '1'(set), check the description to understand the calibration error. FT-112 User Manual Rev. 2.0.0, June 2022 Page 174 of 180...
  • Page 176: Sealing Of Approved Scale

    EALING OF PPROVED CALE Sealing With sticker FT-112 User Manual Rev. 2.0.0, June 2022 Page 175 of 180...
  • Page 177: Trouble Shooting

    ROUBLE HOOTING FT-112 weighing indicator has been designed as a very reliable and virtually error free instrument. However, if an error occurs, do not attempt to repair the equipment before understanding what caused the error. Note the problems you have with your instrument and the error messages shown on the display. Then try to solve the problem using the error table below.
  • Page 178 - Check Alibi SD card. installed. - Change mainboard. Alibi SD card is not supplied E41 ALIBI FAULT - Install Flintec Alibi SD card. from Flintec. Alibi memory serial number - Please format the alibi memory SD card. E42 NEW ALIBI error.
  • Page 179 Capacity of the load cell is E92 DLC UNMATCH - Check capacity of the DLC different. 1) yy = Number / Address of the digital load cell. FT-112 User Manual Rev. 2.0.0, June 2022 Page 178 of 180...
  • Page 180 FT-112 User Manual Rev. 2.0.0, June 2022 Page 179 of 180...

Table of Contents