  • Page 1 FT-107 Weighing Terminal Technical Manual...
  • Page 2: Table Of Contents

    5.2.10 Date and Time ...................... 28 Unit Change ......................29 Application Weighing ............29 Piece Counting ...................... 29 Checkweighing (+/-) ....................32 Animal Weighing ....................34 Temporary Gross Weight Indication ..............34 FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 2 of 46...
  • Page 3 Zero and Span Adjustment ................... 41 7.5.5 [ GrAvit ] Gravity Adjustment ................42 Serial Data Formats .............. 43 Sealing of Approved Scale ............ 44 Trouble Shooting ..............45 FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 3 of 46...
  • Page 4 FLINTEC GMBH reserves the right to revise this manual and alter its content without notification at any time. Neither FLINTEC GMBH nor its affiliates shall be liable to the purchaser of this product or third parties for damages, losses, costs, or expenses incurred by purchaser or third parties as a result of: accident, misuse, or abuse of this product or unauthorized modifications, repairs, or alterations to this product, or failure to strictly comply with FLINTEC GMBH operating and maintenance instructions.
  • Page 5: Safety Instructions

    SECONDS BEFORE ANY CONNECTIONS OR DISCONNECTIONS ARE MADE. FAILURE TO OBSERVE THESE PRECAUTIONS COULD RESULT IN DAMAGE TO OR DESTRUCTION OF THE EQUIPMENT OR BODILY HARM. CAUTION! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 5 of 46...
  • Page 6: Declaration Of Conformity

    This declaration certifies the conformity with the listed Diese Erklärung bescheinigt die Übereinstimmung directives, but it is no promise of characteristics. mit den genannten Richtlinien, beinhaltet jedoch keine Zusicherung von Eigenschaften. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 6 of 46...
  • Page 7: Introduction

    FT-107 has the capacity for 100 records. The scales equipped with FT-107 weighing terminal can be used in all kind of industrial areas up to wet and hygienic environments with its fast and efficient cleaning build to the international guidelines.
  • Page 8: The Front View And Key Functions

    Battery charging level: This sign indicates the battery charging level. Moving level indicates the battery charging. Battery is empty: Announces the battery is discharged and should be charged in a first convenient time. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 8 of 46...
  • Page 9: Key Pad

    3.3.2 Key Pad The keys and the key functions of FT-107(S) in usage are: Power on/off key: Press button to turn it on. To turn it off, press the button for one second. * key: The most frequent used function key. Press to use the selected function.
  • Page 10: Installation Parts

    (will be mounted on the rear of the indicator) Wall mounting plate (will be mounted on the column holder) Battery BAT21 Li-ion 2 x allen screw to install on the indicator support 2 FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 10 of 46...
  • Page 11: Installation

    Disconnect the instrument from power source before start cleaning for your safety. Cover the open glands. FT-107 instrument is designed for using in wet, hygienic and harsh environment. To maintain the instrument, never use harsh abrasive cleaners or solvents. Wipe the instrument with a soft cloth slightly dampened with warm soapy water or with mild detergent.
  • Page 12: Housing

    If the indicator will be used on the table, stick the 4 pieces rubber foots on the back of the indicator (only FT-107). For installation on a round scale column, do not stick the rubber foot and follow the pictures below.
  • Page 13: Electrical Connection

    4.4 Electrical Connection Recommendations 1. Always remember that FT-107(S) indicator is very low voltage measuring instrument in the industrial environment. Your proper installation increases reliability and performance of the instrument. 2. A trained person should interface the instrument because of the 230 VAC voltage in the instrument and against malfunction at installation.
  • Page 14: Load Cell Connection

    Figure 4.4. In 4-wire installations the sense and excitation pins with the same polarity should be short circuited at the connector side. If you have junction box in your system, use 6 wire cable between FT-107(S) and the junction box, and short circuit these pins at junction box for better performance.
  • Page 15: Rs 232C Serial Port

    4.4.2 RS 232C Serial Port FT-107(S) weighing terminal has one standard RS232C and one optional RS232C port. Usage Interfacing with printer, PC, PLC, remote display etc. Data formats Continuous, Continuous 2, Printer Baud rate 1200 / 2400 / 4800 / 9600 (Default) / 19200 / 38400 bps...
  • Page 16: Optional Rs232C Serial Port

    Before connecting the power source check if its voltage is the same as the voltage written on the weighing terminal. Table 4.5 – Power supply connector The protected ground shall be connected to the 230 VAC powered instrument against the safety and electrical disturbances. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 16 of 46...
  • Page 17: Ft-107(S) Functions

    4. If zeroing is not done properly, wait for the sign disappear and press Taring Taring is done to deduct the container weight and to see only the material inside. FT-107 is programmable for 3 types of tare function: Multi tare, Tare/Clear, Automatic tare (Page 25). Warning: Tare value cannot exceed the maximum scale capacity.
  • Page 18 To print the accumulated value, press Enter key if the accumulated value is displayed. To erase the accumulation, press MC and accumulated value will be deleted after your confirmation. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 18 of 46...
  • Page 19: Advanced Functions

    CLU memory is used in piece counting operation. This memory usage and APW saving after sampling are described in to the piece counting operation in Section 6.1 (Page 29). FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 19 of 46...
  • Page 20: Manual Apw Entry

    5.2.4 Manual APW entry: FT-107 indicator has 100 memory locations for counting various materials. The data entry to the CLU memory is carried out in Advanced functions menu by pressing ADV key longer than one second. Follow the diagram below to entry the APW (average piece weight) of the material into the CLU memory.
  • Page 21: Backlight Menu (Only Ft-107S)

    5 seconds. Press Enter key to enter the next item or press Esc key to return to the previous step after selecting backlight by ▲ key. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 21 of 46...
  • Page 22: Configuration Menu

    Press Enter key in Configuration menu to access the backlight adjustment item. Press Enter key to go to the following item or press Esc key to go previous step after selecting backlight by ▲ key. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 22 of 46...
  • Page 23 F key usage You can select this key function from the table below. Disable. Piece count Increased resolution Temporary Gross indication in Net Unit change Animal weighing FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 23 of 46...
  • Page 24 Press Enter key to enter the next item or press Esc key to return to the previous step after selecting dynamic filtering for animal weighing by ▲ key. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 24 of 46...
  • Page 25: Serial Data Outputs

    Press ► key several times until [ dAtA ] prompt appears. Serial data output and printer data formatting related parameters are in this menu. Press Enter key to enter the Serial port-1 setting or press ► key to access other menus. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 25 of 46...
  • Page 26 The first step is the data format. The display indicates two digits at the right the data format. Disable Continuous-1 (Page 43) (select for remote display connection) Continuous-2 (for PC) (Page 43) Printer Single line printer (for PC) FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 26 of 46...
  • Page 27: Printer Setting

    Maximum 16 characters per line. Print-out for wide printers. Maximum 26 characters per line. After changing the printer type with ▲ key, press Enter key to enter the next item. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 27 of 46...
  • Page 28: Date And Time

    Press Esc key to return to [ tESt ] menu. To return to the operation, press the Esc key for the second time. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 28 of 46...
  • Page 29: Unit Change

    The scale counts the pieces on it by using the calculated average piece weight (APW) of the item. In sampling, FT-107 measures a certain number of pieces total weight in very high resolution and divides it by the number of pieces (the so-called sampling quantity) to find average piece weight (APW). Based on this calculated average piece weight, counting can then be carried out.
  • Page 30 2. Place another batch on the scale and press M+ key again to add the second counting number to total [ Cad002 ]. 3. Continue adding further pieces to the memory by pressing M+ key. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 30 of 46...
  • Page 31 To access to memory database press key longer in counting mode or in weighing mode and then ► key. Press Enter key after accessing the CLU memory code with navigation keys. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 31 of 46...
  • Page 32: Checkweighing (+/-)

    Warning: The PLU memory data entries are done in power on unit. In Checkweighing mode, FT-107 offers PLU storage space for 100 different materials and in Piece counting 100 ALU storage space for checking in quantity. For data entries to the PLU / ALU memory press ADV key longer than one second in Advanced function.
  • Page 33 Double sided display scale for multi operator FT-107(S) can be programmed as “Remote” instrument and then connected to the weighing indicator over RS232 port. Double sided display / keypad scale can be configured by using a weighing scale and a remote instrument.
  • Page 34: Animal Weighing

    1. Press the G/N programmed function key in net mode. 2. The indicator activates the signs and indicates the gross weight value. 3. The display goes back to the net weight indication after 5 seconds automatically. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 34 of 46...
  • Page 35: Programming And Calibration

    7. P ROGRAMMING AND ALIBRATION You will find the programming and calibration procedure of FT-107 weighing terminal in this section. Escape key - Return to the menu - Return to the operation without saving parameters. Zero key Fast calibration access.
  • Page 36: Exiting The Programming And Calibration

    Press Esc key to leave the set-up. For example [ bUıLd ] Press Enter key to save the set-up. [ SAVE Press Esc key to return to operation without saving. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 36 of 46...
  • Page 37: Fast Access To The Calibration

    Enter key. Do not touch the [ XXXXX ] scale at [ - - - ] prompt. The next item Linearity Correction prompt appears after the [ LınCAL ] calibration. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 37 of 46...
  • Page 38: Programming And Parameters

    ±3 e Press ▲ key to change the value. Press Enter key to enter to next item or press Esc key to return to the main block. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 38 of 46...
  • Page 39: Stbl: 0.5 ] Stability Delay

    ± 2 e Disable Press ▲ key to change the value. Press Enter key to enter the next item or press Esc key to return to the main block. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 39 of 46...
  • Page 40: Calibration

    [ d : 1 ] Division Select the first division of the scale from available ranges by pressing navigation keys. Press Enter to go to the next item. FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 40 of 46...
  • Page 41: Cal ] Calibration

    4. After a while the [ LoAd ] prompt appears with a suggested test weight on the display as [ XXXXXX ]. For definition of different test weight use the navigation keys. FLINTEC recommends using between 50 and 100% of the scale capacity but minimum 20%. An insufficient weight leads to a calibration error.
  • Page 42: Gravit ] Gravity Adjustment

    2. After a while the [ LoAd ] prompt appears with a suggested test weight on the display as [ XXXXXX ]. For definition of different test weight use the navigation keys. FLINTEC recommends to use between 50 and 100% of the scale capacity but minimum 20%. An insufficient weight leads to a calibration error.
  • Page 43: Serial Data Formats

    ERIAL ORMATS Continuous data and single line data format are described in this section. FT-107´s serial ports are suitable for bi-directional communication. If you transmit ASCII codes for P(print), Z(zero), T(tare) or C(clear) to the one of the serial ports, the indicator will act like the related keys are pressed.
  • Page 44: Sealing Of Approved Scale

    Housing sealing housing sealing Sealing of FT-107S Sealing with sticker: Sealing with lead: Load cell connector and Load cell connector and calibration switch sealing calibration switch sealing FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 44 of 46...
  • Page 45: Trouble Shooting

    ROUBLE HOOTING FT-107(S) weighing indicator had been designed as a very reliable and virtually error free instrument. However, if an error occurs, do not attempt to repair the equipment before understanding what caused the error. Note the problems you have with your instrument and the error messages shown on the display. Then try to solve the problem according to the error table given below.
  • Page 46 www.flintec.com...

Table of Contents