Avery Weigh-Tronix WI-130 WDAC Service Manual
Avery Weigh-Tronix WI-130 WDAC Service Manual

Avery Weigh-Tronix WI-130 WDAC Service Manual

Hide thumbs Also See for WI-130 WDAC:

Advertisement

Quick Links

WI-130 WDAC
Service Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WI-130 WDAC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Avery Weigh-Tronix WI-130 WDAC

  • Page 1 WI-130 WDAC Service Manual...
  • Page 2 This page left intentionally blank.
  • Page 3 Table of Contents Pages are numbered consecutively beginning with the cover page.
  • Page 4: Specifications

    Specifications Power Input Optional 10-32 volts DC and AC noted above Excitation Operational Keys Operational Annunciators Display Display rate A to D Conversion Rate Unit of Measure Capacity Selections Incremental Selections Decimal locations Displayed Resolution Audio Output Time and Date Internal Resolution Harmonizer digital filtering:...
  • Page 5: Front Panel Keys And Functions

    Introduction About This Manual Front Panel Keys and Functions 123456 SERIAL NO. C A P A C I T Y : 0 0 0 0 0 x . 0 L B 0 0 0 0 x . 0 0 K G C L A S S I I I / I I I L PRINT ZERO...
  • Page 6 Hard Keys SELECT UNITS PRINT TARE ZERO ESCAPE CLEAR ENTER...
  • Page 7: Wall Mounting Instructions

    Soft Keys Wall Mounting Instructions...
  • Page 8: Accessing Setup

    Accessing Setup User level Configuration level Calibration level IMPORTANT NOTE Figure 2 Password display...
  • Page 9 User level Figure 3 User level soft key group Figure 4 Soft key flowchart for User level USER-CLOCK Level...
  • Page 10 USER-SELECT Level...
  • Page 11 USER-SET Level...
  • Page 12 USER-VIEW Level Sealed Unsealed...
  • Page 13 Configure level Figure 5 Configuration level display...
  • Page 14 (Select from Appendix 1) Figure 6 Soft key flowchart for Configure level CONFIGURE-MENU 1 Level...
  • Page 17 CONFIGURE-MENU 2 Level...
  • Page 19 CONFIGURE- MENU 3 Level...
  • Page 20: Configure Menu

    CONFIGURE-MENU 4 Level...
  • Page 24 Calibrate level Figure 7 Calibrate level display Figure 8 Soft key flowchart for Calibrate level must...
  • Page 26 Disassembly Figure 10 Back view of the WI-30 Figure 11 Power supply board...
  • Page 27 Figure 12 Main board Figure 13 Display board Re-assembly...
  • Page 28: Appendix 1: Display Samples

    Appendix 1: Display Samples...
  • Page 29 The following are multi-scale displays. If all the lines are not used for scales, they are available for Basic text. #34 & 35 are small basic text. #36 &37 are large basic text.
  • Page 30: Appendix 2: Tips On Using Harmonizer

    Appendix 2: Tips on Using Harmonizer...
  • Page 31 WI-130 WDAC ENCLOSURE PARTS AND ASSEMBLY ITEM DESCRIPTION W-T P/N Nut, Special #10-32 26513-0013 Encl Backplate (Ac Version) 47231-0028 Encl Backplate (Ac-Dc Version) 47231-0010 Cable Assy (Pwr Supply/Main Bd) 47276-0016 Strain Relief 15257-0040 Power Cord (Ac) 15318-0013 Capnut, #10-32 15786-0016...
  • Page 32 WI-130 WDAC SYSTEM BLOCK DIAGRAM...
  • Page 33 WI-130 WDAC AC POWER SUPPLY BOARD P/N 47266 -0018 -0026 (115 VAC), (230 VAC) NOTE: ALL VOLTAGES ARE MEASURED BETWEEN LOGIC GND AND PIN NO.’S UNLESS OTHERWISE NOTED. PIN # SIGNAL TOLERANCES P/S INTERLOCK (NOT USED) +12V +11.5-TO-15.0 VDC +12V +11.5-TO-15.0 VDC...
  • Page 34 WI-130 WDAC MAIN BOARD P/N 47028-0017 P101 EXCITATION CHART P6 Jumper Typ. Exc Position Voltage typical 3-4 10.0 16.0 1-2, 3-4 NOTE (P101): When using barriers, the two pin jumper is not connected and should be stored on pin-1. The barrier should drop the excitation voltage down to the range of (2.0 to 3.8 volts) .
  • Page 35 WI-130 WDAC ANALOG OUTPUT BOARD (OPTIONAL) WI-130 WDAC FRONT PANELOVERLAY (KEYPAD) P/N 47168-0017 P/N 47304-0012...
  • Page 36 WI-130 WDAC 2-5 MULTI-SCALE BOARD (OPTIONAL) P/N 47180: -0011 (2-SCALE INTERFACE), -0029 (2-3 SCALE INTERFACE), -0037 (2-4 SCALE INTERFACE, -0045 (2-5 SCALE INTERFACE) WI-130 WDAC MULTI-SCALE J-BOX ASSEMBLY (OPTIONAL) P/N 47404: -0011 (2-SCALES), -0029 (3-SCALES), -0037 (4-SCALES) -0045 (5-SCALES)
  • Page 37 WI-130 EXTERNAL (16) I/O CUTOFF EXPANSION BD. WI-130 EXTERNAL (8) I/O CUTOFF EXPANSION BD. P/N 49853-0013 P/N 49866-0018...
  • Page 38 WI-130 WDAC QUARTZELL BOARD (OPTIONAL) P/N 47171-0012 (QUARTZELL) WI-130 WDAC MEMORY BOARD (OPTIONAL) P/N 47177-0016...
  • Page 39 WI-130 WDAC ENCLOSURE (W/ STAND) OUTLINE DRAWING...
  • Page 40 WI-130 WDAC ENLCOSURE PANEL MOUNT OUTLINE DRAWING...
  • Page 41 WI-130 WDAC OPTION BOARD CONNECTIONS...
  • Page 42 WI-130 WDAC SOLID STATE CONTROL UNIT (SSCU-8) PARTS AND ASSEMBLY ITEM DESCRIPTION W-T P/N Strain Relief 22380-0053 Strain Relief 15257-0024 Cable , (Sscu-To-Wi-130) 47388-0011 Enclosure (Steel, Painted) 47665-0015 Enclosure (Stainless) 47665-0023 Remote Exp. Control I/O Pc Bd 47183-0018 Lock Nut (Self Sealing)
  • Page 43 Setpoint Operation OPTO-22 CONTROL INTERFACE DEVICES Specifications If setpoints 1 & 2 are programmed in SimPoser as inputs, the physical location for these will always be on the The OPTO-22 Generation 4 I/O modules can be used on the mainboard (max. 2) or on the optional Remote Ex- motherboard TB14.
  • Page 44 SSCU-8 Caution! The Solid State Control Unit 8 (SSCU-8) option boards require that the total cable length from the indicator to the last SSCU-8 box/card be two meters (approx. six feet) maximum. Noise prob- lems and intermittent communications with the SSCU-8 card will occur if this guideline is not followed.
  • Page 45 WI-130 WDAC SSCU-8 REMOTE EXPANDED CONTROL; I/O BOARD P/N 47183-0018 Table 1: Table 3: Setpoints 1 thru 8 Setpoints 17 thru 24 (1)ON (2)ON (3)ON (1)ON (2)OFF (3)ON SETP0INT # TB # PIN # SETP0INT # TB # PIN #...
  • Page 46: Keyboard Specifications

    WI-130 WDAC REMOTE KEYBOARD OPTION BAUD SWITCH SETTINGS RATE 1200 9600 KEYBOARD SPECIFICATIONS ENVIRONMENTAL: 32°f to 130°f (0°c to 55°c). COMMUNICATION OUTPUT: 1 start bit , 8 data bits , 1 step bit- TTL Asynchronous Serial , selectable baud rates .
  • Page 47 WI-130 WDAC-TO-KEYBOARD CABLE CONNECTIONS...
  • Page 48 WI-130 WDAC KEYBOARD OUTLINE DRAWING...
  • Page 49 WI-130 WDAC/KEYBOARD PANEL MTG. DETAIL...
  • Page 50 WI-130 WDAC I/O CABLE IDENTIFICATION AND PIN-OUTS...
  • Page 51: Parts And Assembly

    WI-130 WDAC/QUARTZELL REMOTE BASE 10lb/5kg, 50lb/25kg, 100lb/50kg PARTS AND ASSEMBLY ITEM DESCRIPTION W-T P/N Enclosure Base 1069-12196 Load Bridge 1066-12042 Shroud 1076-11994 Quartzell Assy (10 Lb/5 KG) 7153-13670 Quartzell Assy (50 Lb/25 KG) 7153-10957 Quartzell Assy (100 Lb/50 KG) 7153-12044...
  • Page 52 Weigh-Tronix Weigh-Tronix Canada, ULC Weigh Bar ® is a registered trademark of Weigh-Tronix Inc. 10/12/00 130SERV.P65 PN 29583-0012e3 Printed in USA...

Table of Contents