Specifications Power Input Optional 10-32 volts DC and AC noted above Excitation Operational Keys Operational Annunciators Display Display rate A to D Conversion Rate Unit of Measure Capacity Selections Incremental Selections Decimal locations Displayed Resolution Audio Output Time and Date Internal Resolution Harmonizer digital filtering:...
Introduction About This Manual Front Panel Keys and Functions 123456 SERIAL NO. C A P A C I T Y : 0 0 0 0 0 x . 0 L B 0 0 0 0 x . 0 0 K G C L A S S I I I / I I I L PRINT ZERO...
Page 6
Hard Keys SELECT UNITS PRINT TARE ZERO ESCAPE CLEAR ENTER...
Page 29
The following are multi-scale displays. If all the lines are not used for scales, they are available for Basic text. #34 & 35 are small basic text. #36 &37 are large basic text.
Page 33
WI-130 WDAC AC POWER SUPPLY BOARD P/N 47266 -0018 -0026 (115 VAC), (230 VAC) NOTE: ALL VOLTAGES ARE MEASURED BETWEEN LOGIC GND AND PIN NO.’S UNLESS OTHERWISE NOTED. PIN # SIGNAL TOLERANCES P/S INTERLOCK (NOT USED) +12V +11.5-TO-15.0 VDC +12V +11.5-TO-15.0 VDC...
Page 34
WI-130 WDAC MAIN BOARD P/N 47028-0017 P101 EXCITATION CHART P6 Jumper Typ. Exc Position Voltage typical 3-4 10.0 16.0 1-2, 3-4 NOTE (P101): When using barriers, the two pin jumper is not connected and should be stored on pin-1. The barrier should drop the excitation voltage down to the range of (2.0 to 3.8 volts) .
Page 35
WI-130 WDAC ANALOG OUTPUT BOARD (OPTIONAL) WI-130 WDAC FRONT PANELOVERLAY (KEYPAD) P/N 47168-0017 P/N 47304-0012...
Page 42
WI-130 WDAC SOLID STATE CONTROL UNIT (SSCU-8) PARTS AND ASSEMBLY ITEM DESCRIPTION W-T P/N Strain Relief 22380-0053 Strain Relief 15257-0024 Cable , (Sscu-To-Wi-130) 47388-0011 Enclosure (Steel, Painted) 47665-0015 Enclosure (Stainless) 47665-0023 Remote Exp. Control I/O Pc Bd 47183-0018 Lock Nut (Self Sealing)
Page 43
Setpoint Operation OPTO-22 CONTROL INTERFACE DEVICES Specifications If setpoints 1 & 2 are programmed in SimPoser as inputs, the physical location for these will always be on the The OPTO-22 Generation 4 I/O modules can be used on the mainboard (max. 2) or on the optional Remote Ex- motherboard TB14.
Page 44
SSCU-8 Caution! The Solid State Control Unit 8 (SSCU-8) option boards require that the total cable length from the indicator to the last SSCU-8 box/card be two meters (approx. six feet) maximum. Noise prob- lems and intermittent communications with the SSCU-8 card will occur if this guideline is not followed.
WI-130 WDAC/QUARTZELL REMOTE BASE 10lb/5kg, 50lb/25kg, 100lb/50kg PARTS AND ASSEMBLY ITEM DESCRIPTION W-T P/N Enclosure Base 1069-12196 Load Bridge 1066-12042 Shroud 1076-11994 Quartzell Assy (10 Lb/5 KG) 7153-13670 Quartzell Assy (50 Lb/25 KG) 7153-10957 Quartzell Assy (100 Lb/50 KG) 7153-12044...
Page 52
Weigh-Tronix Weigh-Tronix Canada, ULC Weigh Bar ® is a registered trademark of Weigh-Tronix Inc. 10/12/00 130SERV.P65 PN 29583-0012e3 Printed in USA...
Need help?
Do you have a question about the WI-130 WDAC and is the answer not in the manual?
Questions and answers