Kind KINDNF-1044 Installation & Operation Manual
Kind KINDNF-1044 Installation & Operation Manual

Kind KINDNF-1044 Installation & Operation Manual

Smart metered ph neutralizing filter

Advertisement

Quick Links

Smart Metered pH Neutralizing Filter
Installation / Operation Manual
Model #: KINDNF-1044
kindwater.com
KIND WATER
Have questions? Call us: 888-614-5559
EDUCATION
KINDNF-1044-REV-A-JU24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KINDNF-1044 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kind KINDNF-1044

  • Page 1 Smart Metered pH Neutralizing Filter Installation / Operation Manual Model #: KINDNF-1044 kindwater.com KIND WATER Have questions? Call us: 888-614-5559 EDUCATION KINDNF-1044-REV-A-JU24...
  • Page 2: Table Of Contents

    Control Valve Powerhead Assembly........Page 16 Valve Body Assembly............. Page 17 Bypass Assembly..............Page 18 Service Instructions..............Page 19 Troubleshooting..............Page 22 Error Codes................Page 23 Warranty Information............. Page 24 Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...
  • Page 3: General Specifications

    Please comply with all applicalble plumbing codes Protect the softener and piping from FREEZING TEMPERATURES Please read the entire Installation/Operating Manual and Instruction before installation. This Installation/Operating Manual must stay with the unit. Kind Water Systems - Smart Metered Backwashing Carbon Filter, Installation and Operation •...
  • Page 4: Installation Requirements

    What Is a Smart Metered pH Neutralizing Filter and What Does It Do? The Kind Water Smart Metered pH Neutralizing Filter is essential to water treatment systems that neutralize acidic water and balance pH levels. Utilizing calcite media, composed of naturally occurring calcium carbonate, this media slowly dissolves in acidic water, raising its pH to a more neutral or slightly alkaline range.
  • Page 5 If using PVC or plastic pipe, primers and solvent cements specifically recommended for use with potable water are required. Kind Water Systems - Smart Metered Backwashing Carbon Filter, Installation and Operation •...
  • Page 6: Installation Procedure

    Where the drain line is elevated above the control valve or exceeds 20 feet in NOTE length, 3/4” I.D. drain line tubing should be used. KIND WATER EDUCATION Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...
  • Page 7: Electrical Connection

    Advance control valve to RAPID RINSE (cycle 3) position and allow water to run to drain for 3 to 4 minutes. Advance control valve to SERVICE (cycle 0) position. Kind Water Systems - Smart Metered Backwashing Carbon Filter, Installation and Operation •...
  • Page 8: Programming The Control Valve

    Be certain that the bypass valve is in Service position and main valve is completely on. Check electrical supply to be certain the cord is connected to an uninterrupted 115 volt outlet. Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...
  • Page 9: Utilizing Bluetooth

    Bluetooth Control Utilizing Bluetooth Control For simplified set up and control, please install the Kind Water app on a compatible Bluetooth 4.0+ enabled smart phone or tablet. Download and install the Kind Water app from the Google Play Store, Apple App Store Open the Kind Water app •...
  • Page 10: Set Up Utilizing Bluetooth App

    We do not recommend changing Advanced Settings unless you have a good understanding of the system operation.battery From the Advanced Settings, all items in GREEN with a “set” button can be changed. Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...
  • Page 11 “Go to Next Regeneration Step”. Option 2 “Regenerate Unit at Next Regen Time” button. This will take the system into a backwash cycle at the next regeneration time. Kind Water Systems - Smart Metered Backwashing Carbon Filter, Installation and Operation •...
  • Page 12: Programming The Control Valve

    3. Default setting is 6 days for filters. To Exit Main Menu, press the Menu/Enter button. If no buttons are pressed for 60 seconds, the Main Menu will be exited automatically. NOTE Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...
  • Page 13: Normal Operation

    No other system will be affected. Kind Water Systems - Smart Metered Backwashing Carbon Filter, Installation and Operation •...
  • Page 14 Fast Cycle is not necessary unless desired to manually step through each cycle step. (Repeat until valve returns to the home display) Filters Default (Min) Step 1 Backwash Step 2 Rest Step 3 Rapid Rinse Step 4 Not Used Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...
  • Page 15: Master Programming

    To Exit the Master Programming Mode, press the Menu/Enter button until time of day returns. NOTE If no buttons are pressed for 60 seconds, the Master Programming Mode will be exited automatically. Kind Water Systems - Smart Metered Backwashing Carbon Filter, Installation and Operation •...
  • Page 16 Lower Back Base for Cover 20111X003 Valve Cover 20111X000 Piston Screw 20001X003 Screw SC10 Screw 6 X 1/2 Fenderwasher SST 20001X002 Washer Circuit Board 20111X014 Screw Motor Valve Hex Screw 20001X001 Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...
  • Page 17: Valve Body Assembly

    Injector Seal 20001X224 Injector Plug & O-Ring 20001X217 Assy. Injector Screen 20001x222 Injector Plug & O-Ring 20001X217 Assy. 19/20 Valve O-Ring 20015X043 Dist. O-Ring 20561X204 Meter Assembly 20017X203 Kind Water Systems - Smart Metered Backwashing Carbon Filter, Installation and Operation •...
  • Page 18 Valve Body Assembly Description Part # D15 Bypass (included with all units) 20017X283 1” NPT Elbow Set (included with all units) 20017X284 Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...
  • Page 19: Service Instructions

    10. Slowly crack the inlet knob until a slight flow out the drain line is heard. Let run to drain until all air has escaped. 11. Slowly open both inlet & outlet bypass knobs to the service position. Kind Water Systems - Smart Metered Backwashing Carbon Filter, Installation and Operation •...
  • Page 20 9. Take new piston assembly and push piston into valve by means of the end plug. Twist drive yoke carefully in a clockwise direction to properly align it with drive gear. Reinstall piston retaining plate screws. 10. Follow steps B5 - B9 Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...
  • Page 21 2. Unplug meter cable from front of circuit board. 3. Unscrew meter assembly nut from valve body. 4. Remove meter from valve body and clean or replace as necessary. 5. Reinstall meter, nut and cable. Kind Water Systems - Smart Metered Backwashing Carbon Filter, Installation and Operation •...
  • Page 22: Troubleshooting

    Valve jammed in backwash, brine or Same as above. rapid rinse position Motor stopped or jammed Check for jammed piston. Replace piston and seals. Replace motor if motor is unresponsive. Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...
  • Page 23: Error Codes

    Either way, proceed to the next step. Kind Water Systems - Smart Metered Backwashing Carbon Filter, Installation and Operation •...
  • Page 24 The power supply has come unplugged from the control valve • The power supply is not working Water Treatment Equipment For all warranty information please visit www. kindwater.com/storepolicy/. Kind Water Systems -Smart Metered Backwashing Carbon Filtere, Installation and Operation •...