CO
Monitor
2
 
Model CO200
 
www.ponpe.com
User's Guide
contact:
sale@ponpe.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the CO200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Extech Instruments CO200

  • Page 1 User's Guide Monitor   Model CO200   contact: www.ponpe.com sale@ponpe.com...
  • Page 2: Meter Description

    Introduction Congratulations on your purchase of this Model CO200 Carbon Dioxide Meter. This meter measures CO level, air temp., humidity, date and time. With visible and audible alarms, this is an ideal instrument for indoor air quality (IAQ) diagnosis. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.
  • Page 3: Operation

    RESET button for more than 1 second to activate it. The fan icon keeps flashing when beeps are manually shut down. It stops only when readings fall under the lower limit CO200-EU-EN v1.2 08/13 contact: www.ponpe.com sale@ponpe.com...
  • Page 4: Relay Output

    When the value has been set, press the SET button to confirm the NORMAL limit and to proceed to for setting the upper POOR limit. Press the ESC button to exit without saving the setting. CO200-EU-EN v1.2 08/13 contact: www.ponpe.com...
  • Page 5 ▲ button or the MIN/MAX▼ button. Press the SET button to save the setting and then enter P3. or press the ESC button return to P3. without saving the setting. Repeat as above to finish the setting of P3. (Date), P3. (Hour) and P3. (Minute) CO200-EU-EN v1.2 08/13 contact: www.ponpe.com sale@ponpe.com...
  • Page 6 “No”. Press the ▲ to switch the status then press either the ▲ button to save the settings or the ESC button to exit without saving the settings. Default settings: Parameter Default 700ppm 1000ppm 1000ppm ° CO200-EU-EN v1.2 08/13 contact: www.ponpe.com sale@ponpe.com...
  • Page 7: Manual Calibration

    To abort the calibration, press the RESET button for more than 1 second. Note: Keep away from any animal, human or plant which might affect the CO concentration during the calibration. CO200-EU-EN v1.2 08/13 contact: www.ponpe.com sale@ponpe.com...
  • Page 8: Specifications

    CLEANING AND STORAGE 1. The meter should be cleaned with a damp cloth and mild detergent when necessary. Do not use solvents or abrasives. 2. Store the meter in an area with moderate temperature and humidity. CO200-EU-EN v1.2 08/13 contact: www.ponpe.com sale@ponpe.com...
  • Page 9: Troubleshooting

    Display Air temp. measurement Refer to temperature error code for has error code problem solving The RH calibration has Please return for repair failed RH sensor or measuring Return for repair circuit has failed CO200-EU-EN v1.2 08/13 contact: www.ponpe.com sale@ponpe.com...
  • Page 10 Building bulletin 101 (Bb101): 1500ppm. UK standards for schools say that CO at averaged over the whole day (i.e. 9am to 3.30 pm) should not exceed 1500ppm. Germany, Japan, Australia, UK: 5000ppm, 8 hours weighted average occupational exposure limit is 5000ppm. Copyright © 2013 FLIR Systems, Inc.  All rights reserved including the right of reproduction in whole or in part in any form  ISO‐9001 Certified  www.extech.com  CO200-EU-EN v1.2 08/13 contact: www.ponpe.com sale@ponpe.com...