DANGER: DO NOT MIX CHEMICALS! The PowerBase 3140AT chlorinator system is designed for use with Westlake Water Solu ons approved tablets only. Do not use Cal-Hypo tablets with stabilized chlorine or bromine products, or other sani zing chemicals. Fire or explosion could result.
Page 2
flip a relay in the electrical box causing the pump to turn on/off as needed. The chlorina on system is designed for use ONLY with Westlake Water Solu ons Accu-Tab Blue SI tablets u lizing the Westlake Water Solu ons erosion feeder technology that erodes only the bo om layer of tablets on the sieve plate, while keeping tablets above the sieve plate dry and ready for use.
Installa on Instruc ons 1. Place the chlorina on system in a loca on near the place of applica on. 2. Level the system. This is important for proper chlorine delivery. 3. Connect the inlet flow meter assembly to the solu on tank. The parts were shipped separately to prevent breakage in shipping.
Page 5
Start Up 1. Close the discharge gate valve. 2. Open the feed and discharge isola on valves. Water will begin to fill the solu on tank. 3. When water stops flowing, switch the system “ON” using the chemical controller. The pump will circulate water through the black tubing.
Maintenance Clean the Check Valve and Float Valve at least every 4-6 months, or as needed, to remove scale or debris Winterizing 1. Clean chlorina on system following instruc ons below. 2. Close inlet isola on valve and operate pump un l no more water can be pumped out. 3.
Cleaning procedure 1. Turn system off. 2. Open lid and remove all tablets. Use proper protec ve equipment when handling chemicals. 3. Switch system on to begin flushing the system. 4. Wash out the feeder with a hose to remove remnants of tablets and loosen scale. 5.
Page 8
Chlorinator Top Orienta on Align the chlorinator top por on so that the pointer on the separa on plate is directly over the inlet – see photo below. This will prevent chlorine solu on from draining directly onto the float valve assembly.
Page 11
1 ½” Gate Valve GVG-1500-S 9500006 2” Inlet Filter 2-60-F 9501015 Float Valve Kerick 1-1/4” 9501071 Plunger and pin Kerick 1-1/4” 9501072 6” Float Ball 9500038 R2-120 For other ques ons, contact Westlake Water Solu ons Technical Service (855-934-3570) for assistance.
Page 12
CAL-HYPO COMMERCIAL SYSTEM LIMITED WARRANTY Westlake Water Solu ons warrants (subject to the below condi ons) only its tle to this water treatment system equipment (the "System") and that the System will be free of defects in materials and workmanship for a period of eighteen (18) months from its original shipment date.