Summary of Contents for Westlake Axiall Accu-Tab PowerBase 3140AT
Page 1
® ® Accu-Tab PowerBase 3140AT by Axiall, a Westlake Company Installation and Operating Instructions The PowerBase® 3140AT Chlorinator is NSF/ANSI-Listed for pool applications. ® ONLY Axiall Accu-Tab® Blue SI Tablets for commercial pool applications STD 50 are permitted for NSF installations.
Page 2
Description The Accu-Tab PowerBase 3140AT chlorination system incorporates a patented Axiall chlorinator into a compact plug and play system. Included in the system is an integrated, level controlled solution tank and a centrifugal pump. The flow rate through the system is controlled by a manually adjusted valve located on the discharge of the pump.
Installation Instructions Place the chlorination system in a location near the place of application. Level the system. This is important for proper chlorine delivery. Connect the inlet flow meter assembly to the solution tank. The parts were shipped separately to prevent breakage in shipping. Connect the inlet water supply with 2”...
Page 4
PowrBase PowerBase 3140 AT Syem 3140AT Model 3140AT ® Using Accu -Tab Blue and Blue SI Tablets For pool use only ® Standard 50 Flow Through Chlorinator (gpm)
Start Up 1. Close the discharge gate valve. 2. Open the feed and discharge isolation valves. Water will begin to fill the solution tank. 3. When water stops flowing, switch the system “ON” using the chemical controller. The pump will circulate water through the black tubing. 4.
Maintenance Clean the Check Valve and Float Valve at least every 4-6 months, or as needed, to remove scale or debris Winterizing 1. Clean chlorination system following instructions below. 2. Close inlet isolation valve and operate pump until no more water can be pumped out.
Cleaning procedure 1. Turn system off. 2. Open lid and remove all tablets. Use proper protective equipment when handling chemicals. 3. Switch system on to begin flushing the system. 4. Wash out the feeder with a hose to remove remnants of tablets and loosen scale.
Page 8
Chlorinator Top Orientation Align the chlorinator top portion so that the pointer on the separation plate is directly over the inlet – see photo below. This will prevent chlorine solution from draining directly onto the float valve assembly. Pointer Inlet (where flow meter is attached) O utlet Outlet...
Page 11
PowerBase Replacement Parts PurAqua Part # Axiall Part# Hayward 1 ½ HP Pump PAPP1500 9500080 Seal for Hayward Pump SPX1250XZ2C Webtrol 1 ½ HP Pump PC150R 9500185 Option Seal for Webtrol Pumps 70X130-M Pump Contactor 9500145 1½” Inline Flow Meter F-42050LN 9500002 Level Switch...
Page 12
CAL-HYPO COMMERCIAL SYSTEM LIMITED WARRANTY Axiall, a Westlake Company ("Axiall") warrants (subject to the below conditions) only its title to this water treatment system equipment (the "System") and that the System will be free of defects in materials and workmanship for a period of eighteen (18) months from its original shipment date.