Grundfos FireSAFE+ CM 3-3 Installation And Operating Instructions Manual
Grundfos FireSAFE+ CM 3-3 Installation And Operating Instructions Manual

Grundfos FireSAFE+ CM 3-3 Installation And Operating Instructions Manual

Domestic range, grundfos firefighting system
Hide thumbs Also See for FireSAFE+ CM 3-3:

Advertisement

Quick Links

FireSAFE+
Domestic range, Grundfos firefighting system
Installation and operating instructions
FireSAFE+ Domestic range
Installation and operating instructions
(all available languages)
http://net.grundfos.com/qr/i/92951443
GRUNDFOS INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FireSAFE+ CM 3-3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Grundfos FireSAFE+ CM 3-3

  • Page 1 GRUNDFOS INSTRUCTIONS FireSAFE+ Domestic range, Grundfos firefighting system Installation and operating instructions FireSAFE+ Domestic range Installation and operating instructions (all available languages) http://net.grundfos.com/qr/i/92951443...
  • Page 3 FireSAFE+ English (GB) Installation and operating instructions ............4 EU declaration of conformity .
  • Page 4: Table Of Contents

    Product description ......5 The symbols and hazard statements below may appear in Grundfos Intended use ......6 installation and operating instructions, safety instructions and Features .
  • Page 5: General Safety Warnings

    The flow switch can be a normally The pressure gauge shows the system pressure and can be used closed or normally open type. Grundfos only recommends the use to fine-tune the pressure switch setting.
  • Page 6: Intended Use

    The product has been specifically designed to power and relay maintenance digital signals. The signals can come from any source, but Grundfos • possible fire mode: dual pressure switch detected fire, flow recommends that the following important signals are used: switch failure •...
  • Page 7: Features

    2.3.5 Cooling line settings The cooling line characteristics can be programmed through the USB route and the settings file. Grundfos have approved one setting that suits all pump models. Any changes to this are the installer's or user’s responsibility.
  • Page 8: Receiving The Product

    Wear safety shoes and safety gloves when moving the ignition and therefore cause an explosion by flame path. product. Grundfos do not accept any responsibility for the use of the product CAUTION to pump liquids that could be construed as being hazardous to...
  • Page 9: Water Storage Tanks And Mains Water Connection

    CM5 and CM10 models have holes on the bottom for floor mounting. Mounting to a solid surface is strongly recommended by 14.5 Grundfos. Wall mounting Floor mounting dimensions for CM10 The product can be placed on another surface if vibration insulation is used.
  • Page 10 All electrical connections must be carried out by qualified and authorised electricians in accordance with the wiring If repair is required, contact Grundfos. diagram supplied within the product or this manual, the latest I.E.E. regulations and in accordance with the installation standard requirements.
  • Page 11 Pos. Description Remark Optional backup battery J35 – extends the life of the buzzer after power loss. PCB fuse Factory fitted with fuse 500 mA(T) Pump fuse Factory fitted with fuse 15 A(T) Cooling line valve fuse Factory fitted with fuse 500 mA(T) PCB is visible when the lid folded downwards for installation.
  • Page 12: Installation Checklist

    5.3 Installation checklist During the installation phase, do not apply mains power or water to the product. Step Done Activity Action/check/notes Fully read and study this manual. Unpack, inspect for completeness and any damage. Report to supplier or customer. Check that the installation location meets all the requirements in this manual and the latest applicable standard.
  • Page 13: Commissioning The Product

    6. Commissioning the product Do not attempt to start the pump until the system has been filled with water and both the pump and the system WARNING have been primed or vented. Electric shock Death or serious personal injury ‐ Make sure that all protective coverings are held Running the pump dry may permanently damage it.
  • Page 14: System Verification Checklist

    Related information 7. Setting the product 7.5 Pressure switch setting 8.2 Operating panel 6.2 System verification checklist Before the system is signed off and handed over to the customer, the performance of the whole system must be verified. Step Done Activity Action/check/notes Fully read and study this manual. Inspect the installation.
  • Page 15: Setting The Product

    12. Check the configuration, time and date with a laptop. Make sure that they are as expected. 13. Reassemble the front cover. Two text files are available from your local Grundfos agent for customising the product. • settings.txt - allows all programmable parameters to be adjusted •...
  • Page 16 Device Name: FireSAFE+ Device Name: FireSAFE+ Grundfos Pumps Ltd. Grundfos Pumps Ltd. 01525 85 00 00 01525 85 00 00 Installer Name: INSTALLER NAME 1 Installer Name: INSTALLER NAME 1 INSTALLER NAME 2 INSTALLER NAME 2 INSTALLER NAME 3 INSTALLER NAME 3...
  • Page 17: Updating The Software

    2. Remove the front cover and place it on a soft surface to prevent We do not recommend to adjusting the parameters, as scratching. they may impact the compliance of the product to 3. Remove the red plug (1) on the PCB cover. standard. Contact Grundfos. Factory default Description Range value...
  • Page 18: Pressure Switch Setting

    7.5 Pressure switch setting Pos. Description WARNING Pressure switch 1 Electric shock Pressure switch 2 Death or serious personal injury To decrease operating pressure ‐ Removing the pressure switch case exposes the user to electrical voltage and must only be carried out by To increase operating pressure authorised or competent persons.
  • Page 19: Operation

    8. Operation 8.2 Operating panel WARNING Electric shock Death or serious personal injury ‐ The product must be earthed and provided with protection against indirect contact in accordance with local regulations. ‐ Only use Residual Current Breaker with Over-Current (RCBO). ‐...
  • Page 20: Servicing The Product

    9. Servicing the product 9.2 Annual inspection and test Grundfos recommends that the full fire protection system is tested DANGER and inspected every 12 months. This includes the product and Magnetic field ensures that the system remains in first class working order. This is Death or serious personal injury also a requirement within installation standards.
  • Page 21: Annual Inspection And Test Checklist

    9.3 Annual inspection and test checklist Step Done Activity Action/check/notes Inspect the operating panel for any LED fault indications. Investigate See section Fault finding. and resolve any fault conditions first. Isolate the mains power from the product. Follow a safe isolation procedure before working on the product.
  • Page 22: Spare Parts

    9.4 Spare parts Part number Description 92951443 Installation and operating instructions 92910216 CM3-3 pump 92910217 CM3-5 pump 92910218 CM5-3 pump 92910219 CM5-4 pump 92910220 CM5-5 pump 92910221 CM10-2 pump 92910222 CM10-3 pump 92910652 CM3, CM5 outlet assembly 92910653 CM10 outlet assembly 92910658 Dual pressure switch 92910659...
  • Page 23: Fault Finding

    11. Fault finding Fault event, LED Fault detected Remedy • Check that the mains power is available to the product and voltage is in range. See section Operating conditions. • Check that the power cable termination at PCB end is electrically sound. See POWER LED not section Electrical connection.
  • Page 24: Pump Does Not Reach The Duty Point But Continues To Run

    Reset the service timer. See section Operating panel. For more specific details, take a copy of the log files for analysis. For system operation problems, see the dedicated sections for diagnosis. Contact your system installer or Grundfos for anything else. Related information 5.2 Electrical connection...
  • Page 25: Technical Data

    5.4 - 5.0 0.90 instructions FireSAFE+ CM 10-2 28.56 8.4 - 8.0 1.30 FireSAFE+ CM 10-3 40.7 11.0 - 10.0 1.70 CM, CME Data booklet 96903467 All the above documents can also be found on the Grundfos Product Centre website at: www.grundfos.com/uk.
  • Page 26: Decommissioning, Dismantling And Disposal

    1. Use the public or private waste collection service. • upgrading the product 2. If this is not possible, contact the nearest Grundfos company or • removing the system altogether. service workshop. 14.2 Dismantling the product...
  • Page 27 The Grundfos FireSAFE+ range is designed to comply with the recommendations of Standards BS 9251:2021 and EN16925: 2018. This EU declaration of conformity is only valid when published as part of the Grundfos installation and operating instructions (publication number 92951443).
  • Page 28 Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012/3032 Standard used: BS EN IEC 63000:2018 The Grundfos FireSAFE+ range is designed to comply with the recommendations of Standards BS 9251:2021 and EN16925: 2018. This UK declaration of conformity is only valid when accompanying Grundfos instructions. (92951443)
  • Page 29 Unit 1, Ground floor, Siu Wai industrial Turkey www.ba.grundfos.com Centre GRUNDFOS Pumps NZ Ltd. GRUNDFOS POMPA San. ve Tic. Ltd. Sti. E-mail: grundfos@bih.net.ba 29-33 Wing Hong Street & 68 King Lam 17 Beatrice Tinsley Crescent Gebze Organize Sanayi Bölgesi Street, Cheung Sha Wan...
  • Page 30 92951443 03.2024 ECM: 1389238 www.grundfos.com...

Table of Contents