Installation Guide
3. Technical Speci cations
Speci cations
Operation
Operating voltage
Output
Switch rating
Switch type
Terminals
IP rating
Construction
Control pollution
situation
Rated impulse
voltage
Software
classi cation
Storage conditions
This product is an electronic heating timer/programmer for control
of domestic central heating and domestic hot water.
Danfoss Climate Solutions
TS710 - V2
Continuous use
230 Vac ± 10 % 50/60 Hz
Volt free
3A (1) at 230 Vac
1x SPDT Type
1B
max 2.5 mm
IP30 (installed)
EN60730-2-7
Degree 2
Relative Humidity 5 - 95%
Ambient (storage and shipping)
-10 to 60°C
FP720 - V2
2 x 230 Vac
2x SPDT
Type 1B
internally
linked
2
wires
4 kV
A
EN
5