Summary of Contents for ZYC ENERGY SIMPO 5000

  • Page 1 SIMPO 5000 Quick Start Guide_V1.1...
  • Page 2: Warning And Caution

    Contents in SIMPO 5000 Package SIMPO 5000 Module Number Part Name Quantity Terminal Resistor PE Cable Com Cable Power Cable(+) Power Cable(-) Bolt M6 × 16 Copyright © 2024 ZYC Energy Co., Ltd. All Rights Reserved.
  • Page 3: Specification

    1.Select appropriate cables according to the power of your system and electrical requirements. 2. PE Cables(CSA≥25 mm ) with Terminal(SCxx‑6). 3. Communication cable with shield (Cat5 or higher). 4. SIMPO WiFi can be bought from ZYC’s dealers. Copyright © 2024 ZYC Energy Co., Ltd. All Rights Reserved.
  • Page 4: Operational State

    Parallel Com Out ON/OFF Switch On/OFF Parallel Com In DC- Port There are three LEDs on the front panel of SIMPO 5000 that indicate battery status,ALM, RUN and SOC. Status Operational State Error occurs There is no error existing The battery is ON and can be charged and discharged if no error.
  • Page 5 Tighten Torque Requirement: • Power cables: 20 N·m; • PE cable:5 N·m Use feet to support the cabinet and ensure that the wheels are higher than feet. Copyright © 2024 ZYC Energy Co., Ltd. All Rights Reserved.
  • Page 6 Connect to WiFi Dongle OUT: Connect to IN port of next Battery INV: Connect to Inverter Torque=3 N·m Plug the terminal resistor into the "OUT" port of last battery. Terminal Resistor Copyright © 2024 ZYC Energy Co., Ltd. All Rights Reserved.
  • Page 7 Matching with the CAN Communication inverters as below: SIMPO 5000 Victron Selectronic Studer Steca Deye Noark GoodWe CAN_H CAN_L Matching with the RS485 Communication inverters as below: SIMPO 5000 Lux Power RS485A RS485B Copyright © 2024 ZYC Energy Co., Ltd. All Rights Reserved.
  • Page 8 Connect Power Cables & PE Cables & Communication Cable COM Cable Note: DC+ Cable The maximum number of paralleled SIMPO 5000 modules is 64. 2. When multiple cabinets are connected, a DC box is needed to DC- Cable combine the power cables from the cabinets.
  • Page 9: System Start-Up

    When the app is connecting with the hotspot of the SIMPO WiFi, follow the below steps: www.zycportal.com Fill in the WiFi name Open APP Others Link Internet and password of router Copyright © 2024 ZYC Energy Co., Ltd. All Rights Reserved.
  • Page 10 ZYC ENERGY CO., LTD contact us +86 (0)755-2839 4019 sales@zyc.energy service@zyc.energy www.zyc.energy WhatsApp: +86 19168831702 www.zycportal.com Guangke Road 1, Pingshan, Shenzhen, P.R. China...