LED STRIPLIGHT
INSTALLATION INSTRUCTIONS
IMPORTANT - READ ALL INSTRUCTIONS BEFORE INSTALLATION
• Installation and maintenance must be performed by licensed electricians only.
• To avoid risk of electric shock, make sure to turn off main power switch prior to installation or maintenance.
• Must be installed in compliance with National Electrical Code (NEC) in the US or Canadian Electrical Code in Canada.
• Ensure input voltage and frequency are compatible with the fixture. Check product manual for power requirements prior
to installation.
CAUTION
1. Before installation inspect luminaire for any exterior damages or other defects.
2. Before installation confirm luminaire is the correct rated voltage for application.
3. During installation do not damage luminaire with drill or external impact.
4. Do not expose luminaire directly to high heat.
5. Beware of shock when installing luminaire.
6. Do not install in areas where flooding may occur.
7. Do not clean or expose the luminaire to detergent, chemical cleaners or pesticides.
8. Upon completion of installation, ensure the luminaire is tight and secure.
9. Turn power off when disassembling.
10. Do not look directly into LED luminaire when lit.
11. Do not exchange components in luminaire.
12. Do not operate the fixture where ambient temperature is over 40°C or in confined spaces. This is a fire hazard.
13. Do not install luminaire in applications where high vibrations or external shock are present.
Installation Instruction
14. Do not install/operate luminaire in areas where salt content in the air and soil could cause the luminaire to corrode.
15. Do not install luminaire in areas where corrosive substances are present.
16. Do not install luminaire in areas where organic debris can accumulate on luminaire (example: fallen leaves, insects).
Product Cover:
17. In the event of product failure resulting from negligence of above mentioned instructions, limited warranty will not
be applicable.
Surface Mounting Luminaires.Models : ETLSN-2FT/HL/DM,ETLSN-4FT/HL/DM,ETLSN-4FT/LW/DM,
SUITABLE FOR DRY OR DAMP LOCATION
Model shown for reference only
Mounting Options
Installation Step:
Always turn off the power supply from main circuit breaker first!
B:
Chain Mounting with V hook
Attach customer supplied V-Hooks to each end of the luminaire base.Attach customer supplied chain to the V-hooks and mounting surface.
ETLSN-8FT/HL/DM,ETLSN-8FT/LW/DM.
B
C
A
D
Figure 2
Figure 1
A. End cap
A:
End Cap
B. V-Hook opening
B:
Chain Mounting with V hook
C. Surface keyhole
C:
Surface Mounting
D. T-Bar clip opening
D:
T-Bar Clip Mounting Hole

Advertisement

loading
Need help?

Need help?

Do you have a question about the 68024 and is the answer not in the manual?

Questions and answers

Summary of Contents for Standard 68024

  • Page 1 LED STRIPLIGHT INSTALLATION INSTRUCTIONS IMPORTANT - READ ALL INSTRUCTIONS BEFORE INSTALLATION • Installation and maintenance must be performed by licensed electricians only. • To avoid risk of electric shock, make sure to turn off main power switch prior to installation or maintenance. •...
  • Page 2 T-Bar Clip Mounting Hole Attach customer supplied T-Bar clips to the designated opening on the luminaire as show in Figure 2. LED STRIPLIGHT Bring luminaire into T-Bar ceiling grid and secure luminaire to grid. INSTALLATION INSTRUCTIONS OTE: (Please see Figure 1,Rear of Base is provided with holes for mounting.) INSTALLATION: Jiangsu Ever-tie Lighting Co.Ltd Turn off the power before installation...
  • Page 3 Installation Instruction LED STRIPLIGHT INSTALLATION INSTRUCTIONS Additional Accessories Additionnal Accessory Microwave Motion Sensor • Microwave Motion Sensor Installation Instruction Additional Accessories Microwave Motion Sensor Installation Steps : Figure 2 Figure 1 1. Remove lens and unscrew driver cover. Bend knock out tabs found on end of driver cover. See fig.1 Figure 3 2.
  • Page 4 LED STRIPLIGHT INSTALLATION INSTRUCTIONS Programming Settings Default programming • Detection area: 100% • Hold-time: 5s • Daylight sensor: Disable • Stand-by period (corridor function): 10s • Stand-by dimming level: 10% 1 2 3 1 2 3 Bottom Detection Hold Daylight Stand-by Stand-by Area...

This manual is also suitable for:

6802366127