HUMICONTROL S A F E G U A R D I N G V A L U A B L E S E R I E S DEHUMIDIFIER ND50 PRODUCT FEATURES HIGH PREFERRED AUTO EXTENSIVE ROTARY HUMIDITY HUMIDITY COVERAGE COMPRESSOR FREE CAPACITY SETTING...
LIMITED WARRANTY EXTENSION - EXTENDED WARRANTY This product includes: • novita Dehumidifier ND50 • novita Dehumidifier ND50 Operating Instructions & e-Warranty Application (e-copy) • Starter Guide * Please contact us immediately if any of the above-mentioned items are not included.
PRODUCT DESCRIPTION Dehumidifier ND50 FRONT VIEW BACK VIEW Display Screen Water Tank Compartment Pre-Filter Screen Control Panel Water Tank Enhanced Dual Mesh Activated Carbon Filter (Optional) Air Outlet Oscillating Flap Water Level Indicator Internal Housing Carrying Handle Easy Roll Castor Continuous Drainage Port Front Panel Air Inlet Frame...
TECHNICAL SPECIFICATIONS Rated Power 530 Watts (26.7 C/60% RH) Max. Consumption 620 Watts (30 C/80% RH) Extraction Rate 50L/Day (30 C/80% RH) Humidity Setting Available Auto Humidity Sensor Available Easy Roll Castors Available Running Temperature C to 35 Compressor Rotary Coolant R410A Empty Weight...
4 Programmed Modes Unit is preset with 4 programmed Mode (Manual, Silent, Laundry Drying and Fan) for user to select the preferred operating mode to fulfill their discerning needs. Manual Model Silent Mode Laundry Drying Mode Fan Mode Preferred Humidity Setting User can set the humidity level according to individual desire within a range of 40% to 80% at an interval of 5% RH or select Continuous Dehumidification Mode (CO) to effectively remove excess moisture to safeguard and protect your valuables from mold and mildew growth that thrives under high humidity conditions.
Air Outlet Flap Oscillation The air outlet flap oscillates in an angle of 60 to 90 to promote good air circulation and distribute dehumidified air in the room thoroughly. User also has the flexibility to station the air outlet flap at their preferred angle.
Memory Function Unit is equipped with memory function whereby when the unit is rebooted, it will operate based on the last preceding setting. In the event if the dehumidifier is switched off by a sudden power cut off or when the power plug is disconnected from the power supply, unit auto switch on and resume its operation when the power is restored.
Pre-Filter Screen & Enhanced Dual Mesh Activated Carbon Filter ◊ Pre-Filter Screen at the back panel sieves out contaminants from the air that is drawn into the unit. This process increases the efficiency of the unit and helps to filter the air that is released back into the surroundings.
USING THE NOVITA DEHUMIDIFIER Setting Up 01. Remove all packaging materials and place the unit on a dry, stable and level surface. • DO NOT remove the polystyrene from the water tank. 02. From the back of the unit, place your fingers into the two semi-circle grooves and pull the Air Inlet Frame outwards to remove it from the unit.
Page 10
B. Silent Mode At Silent Mode, the indicator illuminates. The unit is programmed to operate at fan speed 1 with all light indicators dimmed by default. • At Silent Mode, fan speed is preset at fan speed 1 and cannot be adjusted while humidity setting can be adjusted in accordance to user preference.
Page 11
07. Childlock Touch and hold the Childlock Button for 3 seconds to activate the Childlock to lock the control panel. Its corresponding indicator illuminates and flashes on the display screen. To deactivate Childlock, touch and hold the Childlock Button for 3 seconds once again. 08.
EMPTYING THE WATER TANK novita Dehumidifier ND50 shut off automatically when the water tank is full and unit beeps 10 times with its corresponding indicator illuminates on the display screen. Follow the simple steps below to empty the water tank.
• DO NOT use the dehumidifier without the Air Inlet Frame and Pre-Filter Screen in place. CLEANING & MAINTENANCE Cleaning the novita Dehumidifier It is important to conduct service maintenance of the unit at Front Back...
• Remove the water tank and empty it, then replace it into the unit again. • Water tank not placed properly. • Remove water tank and replace it into the unit again. • Power plug or cord damaged. • Contact novita Customer Care Centre.
Page 15
POSSIBLE CAUSE CONDITION POSSIBLE SOLUTION Fan not working • Motor may be malfunction. • Contact novita Customer Care Centre. Poor performance • Low temperature or the surrounding • Dehumidifier does not work as or not dehumidifying humidity level is too low.
When emptying the water tank • Before cleaning • During assembly or dismantling the unit • Before moving the unit • Repairs of appliance should only be done by qualified service technicians from novita. Improper repair work can cause considerable danger to the user.