Swimming Pool Line units
installation and maintenance manual
SPL
GB
0412. 6180471_00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPL Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AERMEC SPL Series

  • Page 1 Swimming Pool Line units installation and maintenance manual 0412. 6180471_00...
  • Page 3: Table Of Contents

    Index General instructions for the AHU Safety Handling Electrical connections Hydraulic connections Aeraulic connections Sections assembly Minimum clearances Access to internal components First start-up Operating rules for the R410A gas Maintenance and cleaning Diagnosis and fault solving Unit disposal...
  • Page 4: General Instructions For The Ahu

    Air handling units - SPL Series General instructions for Air Handling Units During the installation, starting-up, use and maintenance phases of the air handling units must be respected the following safety norms: • Proper use of personal protective equipment (DPI).
  • Page 5: Safety

    Air handling units - SPL Series Safety The unit has been designed to redu- company, entity or individual owner dous situations are generated. The ce at minimum the risks for the of the system in which the Aermec machine has been designed so as to safety of operators who has to inte- machine is installed.
  • Page 6: Handling

    Air handling units - SPL Series Handling Packaging • during transport, the unit and Finally check that potential possible accessories must be pro- hydraulic connectors are protec- tected so as to prevent that the ted with the special plastic caps.
  • Page 7: Electrical Connections

    Air handling units - SPL Series Electrical connections EARTHING CONNECTION ELECTRIC BATTERY CONNECTION It is necessary to refer to the wiring WARNING! For the earthing connection of the diagram, enclosed to each coil. Before starting up the installation each section is equip- unit each unit section ped with screw M8.
  • Page 8: Hydraulic Connections

    Air handling units - SPL Series Hydraulic connections All condensate discharges of inlet in systems under negati- It is advisable not to connect the fan section and Etamax ve pressure; traps in parallel. unit must be equipped with • avoid the unsought air...
  • Page 9: Aeraulic Connections

    Air handling units - SPL Series Aeraulic connections For the ducts connection it is advi- and unit; sable to: It is advisable that the supply duct WARNING! • arrange for suitable clamps begins with a straight long tract at It is forbidden start-up to support ducts in order to avoid least 2.5 times the shorter side of...
  • Page 10: Sections Assembly

    Air handling units - SPL Series Sections assembly The units supplied with different they are connected by means of tions, fixed to the two frames with sections must be composed, fol- two screws with nut for each angle screws selfpunching and connected...
  • Page 11: Minimum Clearances

    Air handling units - SPL Series Minimum clearances In order to collocate the unit it collectors, and on the opposi- If the unit must be installed is recommended to respect the te side a distance equal to unit close to a wall, it is necessary...
  • Page 12: Access To Internal Components

    Air handling units - SPL Series Access to internal components In order to access to the com- P L A N E F I LT E R S O N T H E EXHAUST FANS (B) ponents, which need checks or...
  • Page 13: First Start-Up

    Air handling units - SPL Series First start-up Bevor starting-up the air han- Bevor Aermec assistance service FILTER dling unit are necessary preli- intervention, all electrical and Check the following aspects: minary inspections of the elec- hydraulic connections, charge • suitable collocation and cells trical and cooling parts.
  • Page 14: Operating Rules For The R410A Gas

    Air handling units - SPL Series Instructions for refrigerant R410A Systems operating with refrigerant sal and, after discharge, re-charge - In vacuum conditions not to sup- R410A are subject to a pressure it with necessary quantity. ply voltage to compressor; not to...
  • Page 15: Maintenance And Cleaning

    Air handling units - SPL Series Maintenance and cleaning WARNING: DURING MAINTENANCE PHASE IT IS RECOMMENDED TO USE SUITABLE PROTECTION EQUIPMENT (DPI). With a month frequency must be The month frequency is nur indi- realized the operations mentio- cative as some components can...
  • Page 16: Diagnosis And Fault Solving

    Air handling units - SPL Series Diagnosis and fault solving In the following diagram are Bear mind that further fault (Please see the regulation quoted some possible solu- causes can depend on instal- manual supplied loose the tions to the main faults lation in which the unit ope- unit).
  • Page 17: Unit Disposal

    Air handling units - SPL Series Unit disposal HOW TO DISCONNECT THE UNIT Bevor disassembly and disposal The unit must be managed in a phases the unit can be stocked specialized centre for reuse, The operations to disconnect the outside too, as bad weather and recycling and material recovery.
  • Page 20 Technical data shown in this booklet are not binding. Via Roma, 996 - Tel. (+39) 0442 633111 Aermec S.p.A. shall have the right to introduce at any time wha- Telefax (+39) 0442 93730 - (+39) 0442 93566 tever modifications deemed necessary to the improvement of the product.