TESTO 570 Instruction Manual

TESTO 570 Instruction Manual

Digital manifold
Hide thumbs Also See for 570:

Advertisement

Quick Links

testo 570 · Digital manifold
Instruction manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 570 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TESTO 570

  • Page 1 570 · Digital manifold Instruction manual...
  • Page 3: Table Of Contents

    First steps ....................13 Using the product .................. 17 6.1. Preparing for measurement ............17 6.1.1. Connecting temperature probe, Testo 552 and accessories ......17 6.1.2. Switching the instrument on ................19 6.1.3. Choosing the measuring mode ..............20 6.2.
  • Page 4: Safety And The Environment

    2 Safety and the environment Pos: 3 /TD/Überschriften/2. Sicherheit und Umwelt @ 0\mod_1173774719351_79.docx @ 292 @ 1 @ 1 Safety and the environment Pos: 4 /TD/Überschriften/2.1 Zu diesem Dokument @ 0\mod_1173775252351_79.docx @ 346 @ 2 @ 1 2.1. About this document Pos: 5 /TD/Sicherheit und Umwelt/Zu diesem Dokument/Verwendung/Verwendung (Standard) @ 0\mod_1173775068554_79.docx @ 337 @ 5 @ 1 >...
  • Page 5: Ensure Safety

    (observe local regulations) or return the product to Testo for disposal. Pos: 17 /TD/Sicherheit und Umwelt/Umwelt schützen/testo 550/Kältemittel können schaden testo 550 @ 4\mod_1252656710421_79.docx @ 49869 @ @ 1 > Refrigerant gases can harm the environment. Please note the...
  • Page 6: Specifications

    Pos: 19 /TD/Überschriften/3.1 Verwendung @ 0\mod_1176211016437_79.docx @ 695 @ 2 @ 1 3.1. Pos: 20 /TD/Leistungsbeschreibung/Verwendung/testo 5xx/testo 570 @ 8\mod_1294148437080_79.docx @ 75456 @ @ 1 The testo 570 is a digital manifold for commissioning, maintenance and service work on refrigeration systems and heat pumps. It can be used for fault diagnose and online measurements on refrigeration systems and heat pumps.
  • Page 7 3 Specifications Feature Values Measurement Pressure measurement range HP/LP: -100…5000 kPa / -0.1…5 Mpa ranges / -1…50 bar (rel) / -14.7…725 psi Temperature measurement range: -50…+150 °C / -58…302 °F Measurement range vacuum (rel): -1…0 bar / -14.7…0 psi Overload 52 bar, 5200 kPa, 5.2 Mpa, 754 psi Resolution Resolution pressure: 0.01 bar / 0.1 psi /...
  • Page 8 3 Specifications Feature Values R408A R434A Selectable refrigerants in the R123 R409A R437A instrument R1233zd R410A R438A R1234yf R414B R448A R1134a R416A R449A R420A R450A R290 R421A R452A R401A R421B R455A R401B R422B R502 R402A R421B R503 R402B R422B R507 R404A R422D R513A...
  • Page 9 Measuring cycle 2s..59min 59s (freely selectable) Measurable media Measurable media: all media that are stored in the testo 570. Not measurable: ammonia (R717) and other refrigerants which contain ammonia Ambient conditions Operating temperature: -20 to 50 °C / -4 to 122°F...
  • Page 10 Battery life: > 40h (display light off) Display Type: Illuminated LCD Response time: 0.5 s Directives, EU Directive: 2014/30/EU standards and tests The EU Declaration of Conformity can be found on the testo homepage www.testo.com under the product specific downloads.
  • Page 11: Product Description

    Pos: 24 /TD/Überschriften/4.1 Übersicht @ 0\mod_1176379946003_79.docx @ 733 @ 2 @ 1 4.1. Overview Pos: 25 /TD/Produktbeschreibung/Übersicht/Übersicht testo 570 @ 8\mod_1294147417216_79.docx @ 75423 @ 55 @ 1 Display and control elements 1 Sensor socket Mini-DIN for NTC-temperature sensor, with socket cover.
  • Page 12 4 Product description Icon Meaning The measurement value is saved; in case of a single measurement the inner circle flashes once, with serial measurements the circle flashes with each save procedure. 4 Battery compartment. Charging rechargeable batteries inside the instrument is not possible! 5 Multi-function keys: The relevant function appears in the display.
  • Page 13: First Steps

    Pos: 26 /TD/Überschriften/5. Erste Schritte @ 0\mod_1173774895039_79.docx @ 319 @ 1 @ 1 First steps Pos: 27 /TD/Erste Schritte/testo 570 @ 8\mod_1294152508695_79.docx @ 75489 @ 55555 @ 1 Inserting batteries/rechargeable batteries 1. Unfold the suspension attachment and open the battery compartment (clip lock).
  • Page 14 5 First steps Measurement view is opened. When switching on for the first time, the following factory settings are stored: • Language: English UK • Date: 01.01.2011 • Time: 12:00 To change the default settings: See Fehler! Verweisquelle konnte nicht gefunden werden., page Fehler! Textmarke nicht definiert..
  • Page 15 ISO 817 T... Special Testo designation for certain refrigerants no refrigerant selected. With the software testo Easy Kool you can feed additional refrigerants into the instrument, see separate operating instructions. Efficiency calc.: Select the procedure (COP heat pump) and enter the required parameters (may vary in dependence on selected procedure).
  • Page 16 Mode Function Auto Combi mode When combi mode is activated the digital manifold testo 570 automatically reverses the display of high and low pressure. This automatic reversal occurs when the pressure in the low pressure side is 1 bar higher than the pressure in the high pressure side.
  • Page 17: Using The Product

    Pos: 28 /TD/Überschriften/6. Produkt verwenden @ 0\mod_1173774928554_79.docx @ 328 @ 1 @ 1 Using the product Pos: 29 /TD/Produkt verwenden/testo 570/Anschließen, nullen, einstellen @ 8\mod_1294221048969_79.docx @ 75524 @ 23555355 @ 1 6.1. Preparing for measurement 6.1.1.
  • Page 18 • Before connecting both devices, the testo 552 must be switched on. • The testo 570 will only connect to the testo 552 once Evacuation mode has been activated. • The required pressure unit display must be set in the testo 570.
  • Page 19: Switching The Instrument On

    6 Using the product Position the accessory as appropriate for the measurement task: Measurement task Position (measurement channel) Superheating At the end of the evaporator / inlet of compressor Subcooling At the end of the condenser / inlet of expansion valve Differential temperature On the measurement object Current measurement...
  • Page 20: Choosing The Measuring Mode

    > You should therefore always replace the refrigerant hoses with new ones after the measuring instrument has dropped down or after any comparable mechanical loading. Pos: 30 /TD/Produkt verwenden/testo 570/Messmodus @ 8\mod_1294222104206_79.docx @ 75557 @ 3 @ 1 6.1.3. Choosing the measuring mode 1.
  • Page 21: Performing The Measurement

    6 Using the product Pos: 31 /TD/Produkt verwenden/testo 570/Messung durchführen @ 8\mod_1294222108563_79.docx @ 75590 @ 23533333333 @ 1 6.2. Performing the measurement WARNING Risk of injury caused by pressurized, hot, cold or toxic refrigerants! > Wear protective goggles and safety gloves.
  • Page 22: Tightness Test / Pressure Drop Test

    6 Using the product Key functions > [▲] or [▼]: Change the readings display. Possible display combinations: Evaporation pressure Condensation pressure Refrigerant evaporation Refrigerant condensation temperature to/Ev temperature tc/Co or (only with inserted temperature sensor) Evaporation pressure Condensation pressure Measured temperature t Measured temperature t or (only with inserted temperature sensor) Evaporation pressure...
  • Page 23: Evacuation / Vacuum Display

    Zeroing at ambient pressure must be performed for each vacuum measurement. • In combination with the testo 570, the testo 552 can be used as an external high-precision vacuum probe, if connected to the front of the testo 570 using the connection cable 0554 5520.
  • Page 24: Charging

    6 Using the product • The testo 570 will only connect to the testo 552 once Evacuation mode has been activated. • The required pressure unit display must be set in the testo 570. • In order to be able to use the readings from the testo 552 via the testo 570 in the EasyKool software, you need EasyKool software version 4.0 or later.
  • Page 25: Pressure/Compressor

    The efficiency calculation is displayed. See also Basis of calculation COP, page 32. Pos: 32 /TD/Produkt verwenden/testo 570/Messwerte speichern @ 8\mod_1300291384557_79.docx @ 77486 @ 255 @ 1 6.3. Saving measurement values The testo 570 is able to record a series measurement of up to 999 h.
  • Page 26 Customer Measplace Installation Component. These categories can be changed (e.g. testo / Cellar 1 / Office building 1 / Compressor) and supplemented via the testo software Easy Kool, see separate operating instructions. Saving a single measurement ✓ The desired measuring mode has been selected.
  • Page 27: Printing Measurement Values

    7. Press [Stop]. The serial measurement was stopped. Clock (00:00:00) shows the residual measuring duration. The measurement view is displayed. Pos: 33 /TD/Produkt verwenden/testo 570/Messwerte drucken @ 8\mod_1300291438619_79.docx @ 77558 @ 255 @ 1 6.4. Printing measurement values From the measuring mode ✓...
  • Page 28: Maintaining The Product

    Do not use any aggressive cleaning agents or solvents! Weak household cleaning agents and soap suds may be used. Pos: 36 /TD/Produkt instand halten/Instandhalten testo 570 @ 9\mod_1307460092924_79.docx @ 81023 @ 55555 @ 1 Keeping connections clean > Keep screw connections clean and free of grease and other deposits, clean with a moist cloth as required.
  • Page 29: Tips And Assistance

    Pos: 38 /TD/Überschriften/8.1 Fragen und Antworten @ 0\mod_1177402017078_79.docx @ 1093 @ 2 @ 1 8.1. Questions and answers Pos: 39 /TD/Tipps und Hilfe/Fragen und Antworten/testo 570 @ 8\mod_1301319049211_79.docx @ 78453 @ @ 1 Question Possible causes / solution Batteries are almost empty.
  • Page 30: Measurement Parameters

    8 Tips and assistance Pos: 40 /TD/Tipps und Hilfe/Fragen und Antworten/Messgrößen testo 570 @ 8\mod_1301321170120_79.docx @ 78486 @ 2 @ 1 8.2. Measurement parameters Designation Description ∆toh Superheating, evaporation pressure ∆tcu Subcooling, condensation pressure Refrigerant evaporation temperature Refrigerant condensation temperature...
  • Page 31: Error Reports

    Pos: 43 /TD/Überschriften/8.3 Zubehör und Ersatzteile @ 0\mod_1177402058734_79.docx @ 1102 @ 2 @ 1 8.4. Accessories and spare parts Pos: 44 /TD/Tipps und Hilfe/Zubehör und Ersatzteile/testo 570 @ 8\mod_1291815108682_79.docx @ 74985 @ @ 1 Description Article no. Clamp probe for temperature measurement...
  • Page 32: Appendix

    Basis of calculation COP Heat pump The heating power and the efficiency calculation. COP heat pump are calculated by the testo 570 as follows: • Heating power = Volumetric flow rate x density of medium x specific heat capacity x ∆T (K) / 3600 •...
  • Page 33 4,182 Specific heat capacity capacity x K) of medium in secondary circuit (e.g. water, brine, etc.) The display of the testo 570 shows the following values: • • Heating power (kW) • Feed temperature secondary circuit (e.g. brine circuit) (°C) •...
  • Page 34 0970 5700 en 07...

This manual is also suitable for:

570-2570-10563 57020563 5701

Table of Contents