4VLM HOSES Do not sterilize ENG INSTRUCTIONS FOR USE. Other languages available on https://dental.bienair.com/IFU RX Only REF 2100031-0002/2024-04...
ENG INSTRUCTIONS FOR USE 1 Symbols 1.1 Description of symbols used Description of symbols used S S ymbol ymbol Description Description S S ymbol ymbol Description Description Manufacturer. Catalogue number. Consult instructions for use or consult CE Marking with number of the notified electronic body.
Intended Use specific clinical application. 2.1 Identific Identification ation 2.4 Intended User Intended User Medical devices manufactured by Bien-Air Dental Product intended for professional use only. Used by dentists and dental professionals. Type: 2.5 Use En Use Envir vironment onment Multi-purpose hoses, diameter either of 10 mm or 11 mm.
• The motor is not used simultaneously to the can only be claimed when the device is used with administration of the anaesthetic substances Bien-Air Dental compatible devices (drive motors to the patient. and motors). In addition, only medical power To prevent any risk of infection, supply with 2 MOPP should be used.
Page 7
• It is essential to use dry, purified compressed To prevent any material air in the dental unit in order to ensure the damage the cautions below long working life of the device. Maintain the quality of the air and the water by regular must be observed: maintenance of the compressor and the filtration systems.
They may not give rise to any claim. The original language of those instructions for use is English. For any further information, please contact Bien-Air Dental SA at the address given on the back cover.
Move fully to the stop, in the Move in the direction indicated. direction indicated. 1. 1. To connect the motor to 4VLM Bien-Air Dental hoses, remove the nut (FIG. 2a) from the hose and remove the sleeve from the motor by pushing it forward (FIG.
FIG. 4 . 4 4.2.2 Turbine coupling 1. 1. Screw the 4 VLM Bien-Air Dental hose to the nut (FIG. 4a). 2. 2. Push forward the hose with the screwed nut into the turbine coupling (FIG. 4b). 3. 3. Push fully to the stop the turbine into Unifix quick-couplings 4-hole instruments for optic and non- optic (FIG.
FIG. 5 . 5 4.3 Assembl Assembly y FIG. 5 Preserve the initial alignment of the wires and tubes. Place the metal reinforcement ring (REF 004.26.26) in the chucking zone (FIG. 5a). The securing cord must be attached to the chassis of the unit or table-top device to avoid any traction on the wires and tubes (FIG.
Page 12
FIG. 6 . 6 FIG. 7 . 7 1. 1. The conical piece provided can be useful for connecting the cooling tube to the unit tube (FIG. 6 & FIG.
4.4 T T echnic echnical data al data CAUTION These hoses are not suitable for pressure higher than 5 bar (500 kPa, 72 psi). Standard length 1.70 m Special length Note : Note : See the technical data of the micromotor MOT MC3 (REF 1600680-001), MOT MC3 LK (1600077-001) or MOT MC3 IR (REF 1600071-001) for more information.
5 Maintenance and servicing 5.1 Maintenanc Maintenance – Gener e – General inf al information ormation CAUTION • Non-sterilizable. • Never submerge the hose in disinfectant solutions (the connectors should never be completely submerged). • Do not use an ultrasonic cleaner. 5.2 Cleaning Cleaning Clean with a clean cloth moistened with either tap water, sterile demineralized (deionized) water or any...
Servicing Bien-Air Dental SA recommends that the user change the hose every two years. CAUTION Never disassemble the device. For any inquiry, contact your regular supplier or Bien-Air Dental service centre. 6 Transport & disposal 6.1 T T r r ansport...
The warranty period is: • 12 months from the date of invoicing. In the event of justified claim, Bien-Air Dental or its authorised representative will fulfil the company’s obligations under this guarantee by repairing or replacing the product free of charge.