Installation Instructions - Miele T 9802 VENT ED DRYER Operating And Installation Instructions

Vented dryer
Table of Contents

Advertisement

Fault indicators
The "Check Filter/Vent" indicator lights.
Possible fault
The dryer does not work
at its optimum or not
efficiently. The lint filter
might be clogged with
lint or detergent
residues.
The exhaust duct may
be too long. This is not a
fault.
The ducting is clogged
or kinked.
A program is canceled.
The "Check Filter/Vent" indicator flashes.
The fault cannot be
detected immediately.
The dryer is making a thumping or grinding sound.
The sound is caused by
the high airflow rate in
the ducting of the dryer.
This is not a fault.
Frequently asked questions
Solution
– Usually cleaning the lint filter fixes the problem.
If the problem persists, check all possibilities as
described under "The program runs too long or
stops".
– Open and close the door to turn off the indicator.
With a long exhaust duct, program times and energy
consumption increase. See Installation Instructions.
Check that the ducting is not blocked.
– Check the possible faults as described above.
– Open and close the door to turn off the indicator.
– Start a program.
If the problem persists contact Technical Service.
– To determine if the noise is due to airflow,
temporarily remove the exhaust duct from the
appliance. If the noise lessens, the ductwork is the
cause of the noise. Rigid or flexible aluminum
ducting is the best option for reducing the noise.
If the problem persists please contact Technical
Service.
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T9802 -T 9802

Table of Contents