ERT-A2-CBL
Installation / Wiring Guide
Antenna Installation
SOLAR PANEL
(See Notes)
WEATHERPROOF
CONNECTORS WITH
SURGE
"3M 23" TAPE
ARRESTOR
(OPTIONAL)
COAXIAL CABLE
ERRTS
TM
Flood Warning
OPTIONAL
PWR /OK
TX
PADLOCK
RX
SENSOR
TEST MODE
TX TEST
ERT-A2
PROVIDE GOOD GROUND
CONNECTION TO MAST, MODULE
CHASSIS
AND SURGE ARRESTOR
GND
Wavelength Guide
150MHz = 150cm
340MHz = 88cm
450MHz = 66cm
IF GROUND CONDITIONS ARE
POOR, INSTALL MORE THAN
900MHz = 33cm
WARNING!
EXPLOSION HAZARD
DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS
AREA IS KNOWN TO BE NON-HAZARDOUS
Statutory Requirements
EC: Unlicensed operation limits the radio power. High gain aerials may
only be used to compensate for cable losses.
Internal Battery Connection:
If unit has internal battery option, the battery is not connected to
1 wavelength
unit during shipping.
minimum
To connect the internal battery:
· Remove the battery holder by removing the two Philips
screws and then remove the battery bracket.
COLINEAR
· Locate the battery connector on the ERT-A2 circuit
ANTENNA
board at the top right of battery as shown in picture
below.
· Plug the battery cable connector into the two pin
connector on circuit board being careful to get the
correct orientation for the connector key.
STRESS RELIEF
LOOP
MAST
· Once battery is connected the unit will power ON and
with the default configuration start transmitting a data
packet.
· In normal operation you will see the PWR/OK Led flash
every 10 seconds.
ONE STAKE
Battery
CONNECTIONS:
Wiring Entry: IP66 M20 Cable entry Gland (5-13mm)
2
Terminals: PushIN connection max 0.2 – 1.5mm
wire.
SERIAL
6
7
8
9
1
2
3
4
5
D1
D2
D3
D4
RS232:
Alternative Configuration
&Communications
DIGITALS:
ANALOGS:
Ꝋ
Ꝋ
GND:
GND:
Ꝋ
Ꝋ
DIO1: ON/OFF, Pulse, Enc
AIN1 -/+: 4-20mA Current Loop
Ꝋ
Ꝋ
DIO2: ON/OFF, Pulse, Enc
AIN2 -/+: 4-20mA Current Loop
Ꝋ
Ꝋ
DIO3: Pulse only
+24V LOOP: +24V Loop Supply
Ꝋ
DIO4: ON/OFF only
Ꝋ
GND:
PWR / OK:
Short Green Flash 10Sec : Normal
Green ON : Active
Short Red Flash : Low Battery
TX:
Green : Transmitting data
RX:
Green : Receiving Strong Signal
SENSOR:
Green : Analog Loop or SDI-12
supply active
TEST MODE:
Green : Test transmission
Red : Maintenance Mode
TX TEST:
Short press (<5Sec) : Send Test Transmission
Long Press (>5Sec) : Enable Maintenance Mode
1-HTR
2-SOL
3-GND
4-BAT
1
2
3
4
-
+
-
+
-
+
AI1
AI2
RS485
Ꝋ
1 - HTR: Control for internal Heater
Ꝋ
2 - SOL: Solar Panel 30W 2A Max or Ext Supply 17-30Vdc
Ꝋ
3 - GND: Enternal Power -ve Supply
Ꝋ
4 - BAT: External Power 11-15 Vdc
SENSOR / RS485:
Ꝋ
+12COMMS: SDI-12 Power Supply
Ꝋ
GND: Common GND
Ꝋ
RS485 - : ALERT Data output for RX Base.
Ꝋ
RS485 + : ALERT Data output for RX Base.
Ꝋ
SDI-12: SDI-12 Data IN/OUT.
Ꝋ
GND: Common GND
© ELPRO Technologies Pty. Ltd. 2021 Rev. 1.4
ERRTS
TM
Flood
Warning
PWR /OK
TX
RX
SENSOR
TEST MODE
TX TEST
ERT-A2
RESET:
Reboot unit
USB B:
Config / Diagnostics
USB A:
Download Logged data / Firmware upgrade
TEST:
Short press to send input data message.
Long press (5sec) to send logged data to
USB