415U-1 Condor Wireless Battery IO
Installation Guide Cable Gland Wiring
Antenna Installation
SOLAR PANEL
(See Notes)
WEATHERPROOF
CONNECTORS WITH
SURGE
"3M 23" TAPE
ARRESTOR
(OPTIONAL)
COAXIAL CABLE
CONDOR
Wireless I/O
OPTIONAL
PWR /OK
TX
RX
PADLOCK
SENSOR
TEST MODE
TX TEST
415U-1
PROVIDE GOOD GROUND
CONNECTION TO MAST, MODULE
CHASSIS
AND SURGE ARRESTOR
GND
Wavelength Guide
150MHz = 150cm
340MHz = 88cm
IF GROUND CONDITIONS ARE
450MHz = 66cm
POOR, INSTALL MORE THAN
900MHz = 33cm
WARNING!
EXPLOSION HAZARD
DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-
HAZARDOUS
NE PAS DÉBRANCHER PENDANT QUE LE CIRCUIT EST SOUS TENSION À MOINS QUE LA
ZONE SOIT CONNUE SOYEZ NON DANGEREUX
The 415U-1-C4-EX, 415U-1-C3-EX, 415U-1-C1-EX and 415U-1-C9-EX are suitable for use in Class 1,
Division 2, Groups A, B, C and D; Tamb –40° C to +70° C or non-hazardous locations only.
This equipment shall be installed in accordance with the requirements specified in Article 820 of the
National Electrical Code (NEC), ANSI/NFPA 70-2011. Section 820.40 of the NEC provides guidelines for
proper grounding, and in particular specifies that the antenna ground (shield) shall be connected to the
grounding system of the building, as close to the point of cable entry as practical.
The earth/ground terminal of this equipment shall be connected to earth ground in the equipment
installation.
The supplied Nylon Cable Glands and Blanking Plugs are rated UL94V-2 and are not suitable for
installations within Hazardous Locations. Use metal conduit or components with flammability rating
UL94V-1 or better.
The external power supply installed with this equipment shall be a listed, Class 2 power supply, with
rated output between 17 Vdc and 30 Vdc, and minimum 2A
DO NOT connect voltage to terminal 4-BAT when using an internal battery
NE PAS connecter la tension à la borne 4-BAT lors de l'utilisation d'une batterie interne
DO NOT connect voltage to terminal 2-SOL when using a Lithium Primary (non-rechargeable) battery
NE PAS connecter la tension à la borne 2-SOL lors de l'utilisation d'une batterie au lithium primaire (non
rechargeable)
Battery Power Applications:
Units shipped with internal battery option, do not have the battery connected
1 wavelength
during shipping.
minimum
CAUTION - Lithium Primary (LiP non-rechargeable) internal battery: DO NOT
connect external voltage directly to battery terminals or to supply/solar terminals as
this battery is NOT rechargeable and damage may result.
COLINEAR
CAUTION - Lithium Iron Phosphate (LFP rechargeable): DO NOT connect
ANTENNA
external voltage directly to battery terminals as this may result in damage or
overheating of battery pack.
To connect the internal battery:
·
Remove the battery holder by removing the two Philips screws and battery
STRESS RELIEF
bracket.
LOOP
·
Locate the battery connector located at the top
right of battery as shown in picture.
MAST
·
For internal battery connect the battery by
plugging battery cable connector onto the two
pin connector on circuit board located to right
of internal/external selection link, using correct
orientation (keyed).
·
The PWR/OK LED green flash every 10 seconds in normal operation. See unit
configuration on reverse side of this document.
ONE STAKE
Battery
CONNECTIONS:
Wiring Entry: IP66 M20 Cable entry Gland (5-13mm)
Terminals: PushIN connection max 0.2 – 1.5mm
wire.
SERIAL
6
7
8
9
1
2
3
4
5
D1
D2
D3
D4
RS232:
Alternative Configuration
&Communications
DIGITALS:
ANALOGS:
Ꝋ
Ꝋ
GND:
GND:
Ꝋ
Ꝋ
DIO1: ON/OFF, Pulse
AIN1 -/+: 4-20mA Current Loop
Ꝋ
Ꝋ
DIO2: ON/OFF, Pulse
AIN2 -/+: 4-20mA Current Loop
Ꝋ
Ꝋ
DIO3: ON/OFF, Pulse
LOOP: +24V Loop Supply
Ꝋ
DIO4: ON/OFF only
Ꝋ
GND:
PWR / OK:
Green Flash 10Sec – Normal
Green ON – Active
Red Flash – Low Battery
TX:
Green – Transmitting data
Red – Transmit Fault/Failure
RX:
Green – Strong Signal
Red – Weak Signal
SENSOR:
Green – Analog Loop or SDI-
12 supply active
TEST MODE:
Green – Test transmission
TX TEST:
Short press (5Sec) – Send
test transmission
2
TEST
1-HTR
2-SOL
3-GND
4-BAT
1
2
3
4
-
+
-
+
-
+
AI1
AI2
RS485
Ꝋ
1 - HTR: Control for internal Heater
Ꝋ
2 - SOL: Solar Paanel 30W 2A Max or Ext Supply 17-30Vdc
Ꝋ
3 - GND: Enternal Power -ve supply
Ꝋ
4 - BAT: External Power 11-15Vdc
SENSOR / RS485:
Ꝋ
GND:
Ꝋ
+12COMMS: SDI-12 Power Supply
Ꝋ
GND:
Ꝋ
RS485 -/+: RS485 Modbus Smart Sensor.
Ꝋ
SDI-12: SDI-12 Data IN/OUT.
Ꝋ
GND:
© ELPRO Technologies Pty. Ltd. 2020 Rev. 1.2
CONDOR
Wireless I/O
PWR /OK
TX
RX
SENSOR
TEST MODE
TX TEST
415U-1
RESET:
Reboot unit
USB B:
Config / Diagnostics
USB A:
Download Logged data /
Firmware upgrade
TEST:
Short press to send input
data message.
Long press (5sec) to send
logged data to USB
SUPPLY: