VSP & FSP Peristaltic Metering Pumps
Industrial Series
VSP & FSP Operating Manual
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Industrial VSP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for anko Industrial VSP

  • Page 1 VSP & FSP Peristaltic Metering Pumps Industrial Series VSP & FSP Operating Manual ®...
  • Page 2: Table Of Contents

    ® ankoproducts.com TABLE OF CONTENTS 1.0 SAFETY 2.0 SPECIFICATIONS 3.0 INSTALLATION 4.0 OPERATION 4.1 Controls 4.2 Adjusting Flow Output 4.3 Remote Operation 5.0 MAINTENANCE 5.1 Routine Inspection 5.2 Tube Replacement 5.3 Pumphead Maintenance 5.4 Fuse Replacement 6.0 PARTS & ACCESSORIES 7.0 TROUBLESHOOTING 8.0 LIMITED WARRANTY 9.0 RETURNS &...
  • Page 3: Safety

    5% to 100% Run Time Adjustment (Timer Models) 0% to 100% Motor Type Brushless DC Duty Cycle Continuous Tubing Accepted Anko Premium Class Tubing Bores Accepted 1/4", 3/16” & 1/8” Operating Voltage 100-240 50/60Hz Plug Type NEMA 5-15P Max Working Pressure...
  • Page 4: Installation

    ® ankoproducts.com Materials of Construction Enclosure Polypropylene Pump Head Polycarbonate Rollers MoS2 Filled Nylon Rotor CRS – Zinc Plated Dimensions 3.0 INSTALLATION When facing the pump, the roller assembly spins in a clockwise direction. The inlet (suction) side is located •...
  • Page 5: Operation

    ® ankoproducts.com 4.0 OPERATION WARNING: Tube failure may result in fluid being sprayed from pump. Use appropriate measures to protect operator and equipment. Tubing should be inspected periodically for tears, cracks, cuts, or abrasions. Use only factory approved tubing from the designated tubing class. Incorrect tubing can WARNING! adversely affect performance or damage the pump.
  • Page 6: Remote Operation

    ® ankoproducts.com 4.3 Remote Operation Remote Start/Stop – For pump models equipped with remote start/stop, this feature operates by receiving a dry contact signal and is intended to be connected to a dry contact switch. The input has no polarity. No voltage is permitted on the input signal.
  • Page 7: Maintenance

    ® ankoproducts.com 4-20mA Control (Continued) To establish and operate the analog control feature: Install the two-wire lead (right side of terminal is positive; left is negative) from the 4-20mA source into the terminal block (Figure 4). Set the potentiometer to the desired scaling percentage. To operate without scaling, set the potentiometer to 100%.
  • Page 8 ® ankoproducts.com 5.2 Replacing the Tubing (Continued) Tubing Removal When facing the pump, the roller assembly spins in a clockwise direction. The inlet (suction) side is located on the left side of the pumphead, and the outlet (discharge) is located on the right. Disconnect any suction and discharge tubes from the pump tube.
  • Page 9: Tube Replacement

    ® ankoproducts.com 5.3 Pumphead Maintenance Remove tubing per the Tubing Removal procedure. Disconnect power to the pump. Remove the pumphead cover. Slide roller assembly off motor shaft. For two roller configurations, first open the spring clip to release it from the motor shaft (Figure 9).
  • Page 10: Troubleshooting

    ® ankoproducts.com 7.0 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Pump tube worn Replace tubing Ensure system pressure does not exceed tube Fluid Leaking Excessive back pressure pressure rating Tube connections are not tight Ensure tubing connections are properly connected Non-compatible tubing used Use specified tubing Tube Life is Seized rollers caused abrasion on tube...
  • Page 11: Limited Warranty

    ANKO disclaims all liability for any loss, damage or expense directly or indirectly related to or arising from the use of its products, including damage to other products, machinery, or property. ANKO shall not be liable for any consequential damages including, without limitation, loss of profits, loss of product or loss of production.