anko VSP Operating Manual

anko VSP Operating Manual

Peristaltic metering pumps

Advertisement

®
PERISTALTIC METERING PUMPS
MODELS: VSP & FSP
OPERATING MANUAL
28-VSP-FSP-00 Rev A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VSP and is the answer not in the manual?

Questions and answers

Summary of Contents for anko VSP

  • Page 1 ® PERISTALTIC METERING PUMPS MODELS: VSP & FSP OPERATING MANUAL 28-VSP-FSP-00 Rev A...
  • Page 2: Table Of Contents

    ® ankoproducts.com TABLE OF CONTENTS 1.0 SAFETY 2.0 SPECIFICATIONS 3.0 INSTALLATION 4.0 OPERATION 4.1 Controls 4.2 Adjusting Flow Output 4.3 Remote Operation 5.0 MAINTENANCE 5.1 Routine Inspection 5.2 Tube Replacement 5.3 Pumphead Maintenance 5.4 Fuse Replacement 6.0 TROUBLESHOOTING 7.0 REPLACEMENT PARTS 8.0 LIMITED WARRANTY 9.0 RETURNS &...
  • Page 3: Safety

    5% to 100% Run Time Adjustment (Cycle Timer Models) 0% to 100% Motor Type Brushless DC Duty Cycle Continuous Tubing Accepted Anko Premium Class Tubing Bores Accepted 1/4", 3/16” & 1/8” Operating Voltage 100-240 50/60Hz Plug Type NEMA 5-15P Max Working Pressure...
  • Page 4: Installation

    ® ankoproducts.com Materials of Construction Enclosure Polypropylene Pump Head Polycarbonate Rollers Nylon Rotor Powdered Metal Dimensions 3.0 INSTALLATION • When facing the pump, the roller assembly spins in a clockwise direction. The inlet (suction) side is located on the left side of the pumphead, and the outlet (discharge) is located on the right. •...
  • Page 5: Operation

    ® ankoproducts.com 4.0 OPERATION WARNING: Tube failure may result in fluid being sprayed from pump. Use appropriate measures to protect operator and equipment. Tubing should be inspected periodically for tears, cracks, cuts, or abrasions. WARNING! Use only factory approved tubing from the designated tubing class. Incorrect tubing can adversely affect performance or damage the pump.
  • Page 6: Maintenance

    ® ankoproducts.com 4.3 Remote Operation (Cont.) 4-20mA Control – For pump models equipped with 4-20mA speed control, this feature operates by receiving a 4-20mA input signal which controls the pump’s motor speed. The minimum speed is 5% at 4.8mA and increases in 1% increments for every .16mA until 100% speed is reached at 19.9mA. Loop voltage may not exceed 24VDC.
  • Page 7: Pumphead Maintenance

    ® ankoproducts.com 5.2 Replacing the Tubing (Cont.) Tubing Installation Figure 3 Figure 4 Figure 5 Start with a section of tubing at least 9” in length. Once installed, this length will result in approximately 1 1/2” extending below both sides of the pumphead for fittings and attachments. 1.
  • Page 8: Troubleshooting

    ® ankoproducts.com 6.0 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Pump tube worn Replace tubing Ensure system pressure does not exceed tube Fluid Leaking Excessive back pressure pressure rating Ensure tubing connections are properly Tube connections are not tight connected Non-compatible tubing used Use specified tubing Tube Life is Seized rollers caused abrasion on tube...
  • Page 9: Limited Warranty

    URL: www.ankoproducts.com © 2022 Anko Products Inc. All rights reserved. All trademarks are the property of Anko Products, Inc. and its subsidiaries. Specifications, terms, and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.