Airport Lighting ELA Series Operating & Maintenance Manual

Elevated omnidirectional low intensity ligh

Advertisement

Quick Links

OPERATING & MAINTENANCE MANUAL
MODEL : ELA series
OPERATION & MAINTENANCE
MANUAL
ELA-TEDL : ELEVATED OMNIDIRECTIONAL LOW INTENSITY LIGHT
YOUYANG AIRPORT LIGHTING EQUIPMENT INC.
PAGE 1/24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELA Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Airport Lighting ELA Series

  • Page 1 OPERATING & MAINTENANCE MANUAL MODEL : ELA series OPERATION & MAINTENANCE MANUAL ELA-TEDL : ELEVATED OMNIDIRECTIONAL LOW INTENSITY LIGHT YOUYANG AIRPORT LIGHTING EQUIPMENT INC. PAGE 1/24...
  • Page 2 OPERATING & MAINTENANCE MANUAL MODEL : ELA series YOUYANG AIRPORT LIGHTING EQUIPMENT INC. REVISION RECORD This Revision Record of Manual is written in below Table and we supply new updated Manual with product. This Manual can be revised anytime for better improvement of products and its Revision contents are made by company production process regulation and will give to customers as newly updated Hard copy and Soft copy by CD.
  • Page 3: Table Of Contents

    OPERATING & MAINTENANCE MANUAL MODEL : ELA series CONTENTS 1. General Knowledge before Operation(use) Cautions for Safety Quality guaranty 2. Product specification 3. Installation 4. Maintenance & Repair procedure 5. Transportation & Storage 6. Drawings & Parts List YOUYANG AIRPORT LIGHTING EQUIPMENT INC.
  • Page 4: General

    Please transfer this Manual to person in charge of end user and maintenance person and Duty maintenance manager. Please store this Manual where can see easy by person in charge always and use anytime when required. Company: YOUYANG AIRPORT LIGHTING EQUIPMENT INC. KOREA Department: Quality Assurance Team Tel: +82-31-422-0021...
  • Page 5: Cautions For Safety

    OPERATING & MAINTENANCE MANUAL MODEL : ELA series 1.2 Cautions for Safety Keep this Caution to use products at safely and correctly to prevent before any troubles and dangerous cases are occurred. Use this product function as sufficiently and safely after carefully reading of this Manual.
  • Page 6 OPERATING & MAINTENANCE MANUAL MODEL : ELA series WARNING 1. Do not Repair work when Power is ON and electrical circuit operated. This will make Electric Shock to user. 2. Do not cabling work and disassembly work of products even Power is not connected.
  • Page 7: Quality Guaranty

    OPERATING & MAINTENANCE MANUAL MODEL : ELA series 1.3 QUALITY GUARANTY The product guaranty under this manual applied is 1 year after supply to site. The consumable parts are excluded from guaranty period. The troubles caused by products defects will be free of charge during guaranty period, but, user mistakes and mis-use will be charged.
  • Page 8: Product Specification

    OPERATING & MAINTENANCE MANUAL MODEL : ELA series 2. Product specification 2.1 TEDL: ELEVATED OMNIDIRECTIONAL LOW INTENSITY LIGHT Item Specification In compliance with Operating -40 ~ +60℃ FAA: AC 150/5345-46C temperature Storage -55 ~ +55℃ FAA: AC 150/5345-46C temperature Exposure to rain, snow, ice, and standing...
  • Page 9 OPERATING & MAINTENANCE MANUAL MODEL : ELA series Item Specification In compliance with Wind Velocity 300Not Treatment powder electrostatic painting Surface Treatment Color Aviation yellow FAA: AC 150/5345-46C Body Aluminum die-casting (ALD 6) Dome lens polycabonate(Blue) Composition Lamp socket GY-9.5 2 pole plug L- 823, Style 1.
  • Page 10: Installation

    OPERATING & MAINTENANCE MANUAL MODEL : ELA series 3. INSTALLATION 3.1 General The Light product is supplied after assembled and tested to meet with usages. The Light product is supplied under KS, IEC, ICAO, FAA, MAK regulation requirement and Light capacity, color and intensity can be decided with user to meet with airfield site condition.
  • Page 11 OPERATING & MAINTENANCE MANUAL MODEL : ELA series 3.4 4 INSTALLATION of LIGHT PRODUCT The installation method is followed as below procedure and must be installed in the Deep base or Shallow base. The base(box) installation method is followed by FAA AC 150/5340-26. However, user request special installation method under their country regulation, it will be discussed to decide installation method.
  • Page 12 OPERATING & MAINTENANCE MANUAL MODEL : ELA series 3.4.1 INSTALLATION of Shallow base box ISOLATION TRANSFORMER 2'' GALVAN? Z BORU ISOLATION TRANSFORMER INSTALLATION of Light - Please check below before installation of light. -. All materials and tools are prepared? -.
  • Page 13 OPERATING & MAINTENANCE MANUAL MODEL : ELA series spanner (50mm). 4) Draw out secondary cable to outside through coupling which is connected with isolation transformer. 5) Lay down light on soft surface. 6) Connect secondary plug of light with receptacle of extended secondary cable of isolation transformer.
  • Page 14 OPERATING & MAINTENANCE MANUAL MODEL : ELA series [Installation procedure of Light] 1) Confirm the base box is installed as beam axes of light with ground level. Refer base box installation method in manual of base box. 2) Inspect base box have damages or not.
  • Page 15 OPERATING & MAINTENANCE MANUAL MODEL : ELA series [Installation procedure of Light] 1) Clean cable pipe(duct) after installation check. There must be no water and wet in pipe and no damages for screws at cable connection part of pipe. 2) Lay light on soft surface for side part.
  • Page 16 OPERATING & MAINTENANCE MANUAL MODEL : ELA series 3.5 Horizontal angle setting PHOTO WORK Take out setting jig from box. Loosen fixing bolt which fixing upper body using driver in order to adjust horizontal angle. Put adjust jig on light fixture.
  • Page 17: Maintenance & Repair Procedure

    OPERATING & MAINTENANCE MANUAL MODEL : ELA series 4. MAINTENANCE & REPAIR PROCEDURE 4.1 Check period & check points This Precaution, Maintenance and Repair works are very important for Aircraft safety operation. The below check points are recommended by FAA for Elevated type Light.
  • Page 18 OPERATING & MAINTENANCE MANUAL MODEL : ELA series 4.2 TROUBLE STATUS & ACTION for Maintenance Please follow up as below action for trouble shooting. *Do change assembly of light at site and then, troubled light must be repaired at maintenance shop to prevent runway shut-down time.
  • Page 19 OPERATING & MAINTENANCE MANUAL MODEL : ELA series 4.3 REPAIR WORK METHOD 4.3.1 Globe & lamp change 1) Tool & Parts Tool Parts 1. glass globe No tool 2. lamp(6.6A/45W) 1EA 3. packing 2) WORK METHOD PHOTO WORK Take off safety pin Remove ring band for loose protection.
  • Page 20 OPERATING & MAINTENANCE MANUAL MODEL : ELA series 4.3.2 Exchanging of Lead wire. 1) Tool & Parts TOOL PART 1. (+) Driver Lead wire 2] Exchanging of lead wire Take off pin for loose protection. Take off ring band. 1) Light 2) Safety pin 3) Ring band Remove globe.
  • Page 21 OPERATING & MAINTENANCE MANUAL MODEL : ELA series Remove lead wire push using tool and separate lead wire from light fixture. 1] Light 2) Packing 3) Lead wire 4) Cord Push 1) Replace to new lead wire. 2) Fix lead wire to light fixture with cord push.
  • Page 22: Transportation & Storage

    OPERATING & MAINTENANCE MANUAL MODEL : ELA series 5. TRANSPORTATION & STORAGE 5.1 STORAGE 1) All Lights are supplied by each packing box and each box have name plate and indicated box content at outside of box. 2) All light must be stored at dry condition without dust in the room.
  • Page 23 OPERATING & MAINTENANCE MANUAL MODEL : ELA series 6. DRWAING & PARTS LIST 6.1 ELA-TEDL : ELEVATED OMNIDIRECTIONAL LOW INTENSITY LIGHT YOUYANG AIRPORT LIGHTING EQUIPMENT INC. PAGE 23/24...
  • Page 24 OPERATING & MAINTENANCE MANUAL MODEL : ELA series PARTS LIST Part of name quantity Ordering NO Dome Lens Lamp Bolt Socker assembly Bolt Socket support Coble clamp 2-Pole plug Gasket Locking pin Lens clomp Bolt Upper body Lower body Bolt Coupling YOUYANG AIRPORT LIGHTING EQUIPMENT INC.

This manual is also suitable for:

Ela-tedl

Table of Contents