3
CARE AND MAINTENANCE
Always turn off the air conditioner and the main power supply before clean the unit.
Switch off the power supply if the unit is not going to be used for a long period of time.
1
Air filter cleaning
It is advisable to clean air filter every two weeks for
longer operation.
(You will find how to clean the filter on page 2 .)
2
Notes
Avoid opening doors and windows
Don't be exposed to cold air for
a long time.
unless necessary.
Use curtain or blind
Keep heat source away from
Direct sunlight may reduce cooling
air conditioner.
effect, always use window curtain.
Don't hang clothes in the vicinity
Temperature should be set properly
of air inlet. This will decrease
when there are infant,child, the
cooling effect and cause abnormal
aged or disabled in the room.
operation.
Baby has
gone sleep,
better to adjust
suitable temp.
4
AIR CONDITIONER INSTALLATION
SELECTION OF THE INSTALLATION POSITION
1,The air-conditioner is better installed in shadow or in a place
with short period of sunshine. In case the air-conditioner is
installed at the point exposed directly to the sunshine, it should
be protected from the direct sunlight as possible in order to
avoid the long time of direct sunlight otherwise its performance
will be lowered. (As illustrated in Fig. 1).
2. For the convenience of operation, it is
recommended that air-conditioner be installed at
least at the height of 760-1300 mm above the
floor and no obstacles before it for a free airflow.
3.The shutters at both sides and the top of
air-conditioner should be protruded outdoors free
from being blocked by wall, window,ect.
4.The back of air-conditioner should be kept over
500mm from the obstacles (for example, wall,
etc.) (As illustrated in Fig. 2).
5.To have an efficient drainage, the back part of
the air-conditioner should be inclined downward
by 5-10mm (As illustrated in Fig. 3).
NOTES:
For longer and trouble-free operation of the unit, pay special attention to the following:
Install air-con at a place strong enough to support the unit.
Leave enough space around air inlet and outlet for better circulation.
Avoid places where flammable gas leaks.
Problems may occur if unit is installed in the following places:
Place where oil exists in the air including engine oil or seaside with
salt breeze blows and hot spring area with sulphurous gas in the air.
THE ENCLOSED ACCESSORIES OF THE CONDITIONER
Drain elbow
Manual
Name
(with seal ring)
Figure
OR
Quantity
1
1
NOTE:Your model will have one Drain elbow of the above two, not both.
Cleaning of the
Set temp . a little bit higher
before going to bed.
Proper
temperature
After unit stops, don't restart it
until 3 min. have elapsed.
OK! Enjoy a
3-min nap
Before operating mode
selection switch, check that if
the air inlet or outlet have been
blocked.
(ONLY FOR REFERANCE)
cover
support
fig.1
>500mm
fig.2
fig.3
Remote
Battery
Rubber lid
controller
1
1
1
PREPARATIONS BEFORE INSTALLATION
Make the wall hole or window hole (see Fig.1)
MODEL
A
HW-09CU03
HW-12CU03
355mm
HW-09CUA03
HW-12CUA03
HW-18CU03
air filter
420mm
HW-18CUA03
Prepare unit for installation:
1.Take out the conditioner and accessories from the package .
2.D isposal of the condensed water.
Block the bottom plate hole of the conditioner
with rubber lid, install
drain elbow on the
back hole and let the condensing water flow from
the back hole of the conditioner. (See Fig.1 ) In
this method, the accumulated condensed water
in the bottom plate is hit by the fan onto the heat
exchanger, and evaporated and blown out
from the machine. It can cool the heat
exchanger adiator more quickly, and improve
the energy efficiency of the conditioner. But the
hitting noise by the fan at the outdoor side is
relatively large.
NOTE:
For some models your Drain elbow may be the
same as Fig.2.
NOTE:
When install drain elbow, adjust the direction of the
drain elbow to make it be in line with the hole in
the rear of unit; Insert the drain elbow into hole
and twist 90°.
INSTALLATION PROCEDURES
1. Fix the prefabricated iron frame to stable position by expansible screws.
2. Put the whole machine with all the accessories installed on the iron frame.
If there's water outlet flexible pipe, lead it to needed position(see Fig.1).
3. Fill any distance between the wall hole and the machine body
with flexible sponge rubber strip to prevent the entering of outer
5
7
noise and the leaking of the coolness.
6
8
4.
Open the Air inlet geille ,fix the front panel to the chassis
firmly with the accessorial
(NOTE:Your model will be the same as one of the right two
illustrations,not both.)
5. After installation of the conditioner, insert the power
plug into the outlet and perform test-run.
Cautions
5
TROUBLESHOOTING
Before calling for service.
Check the following points before calling for repairs or service.
Phenomenon
Switch on the machine but it
does not work immediately.
Switch on the machine but it
does not work.
The cooling effect is not good.
Screw
1
If problems can not be solved please pull out power plug and contact your dealer.
B
A
535mm
580mm
Fig.1
Fig.2
screw.(see Fig.2 or
Fig.3)
Fig.2
Power cord: Be sure to use the exclusive power cord.
Change installation place: If air-con need to be changed to another
place please contact the dealer, who sold you the unit.
Cause or check points
If the machine is started after stop,it will need about 3 minutes to
restart so as to prevent the fuse from break.
Is plug firmly inserted?
Is there power failure?
Does fuse get burned?
Is thermostat switch
wrongly adjusted?
Is there any direct
sunlight in the room?
Are doors or windows
left open?
Are there any obstacles
blocking air inlet and
outlet?
Is air filter clogged?
Is there too much heat
source in the room?
Iron frame
Width of the wall
Fig. 1
Rubber lid
Drain elbow
Rubber lid
Drain elbow
Wall
Water outlet flexible
pipe(provide by user)
Fig.1
Fig.3
Solution
Readjust power supply
Replace fuse.
Readjust the thermostat.
Use curtain or blind.
Shut doors and windows.
Remove the obstacles.
Clean it.
Remove the heat source