Haier HSU-24LEA03-T - annexe 1 Installation Manual
Haier HSU-24LEA03-T - annexe 1 Installation Manual

Haier HSU-24LEA03-T - annexe 1 Installation Manual

Hide thumbs Also See for HSU-24LEA03-T - annexe 1:

Advertisement

Quick Links

Installation Manual of Room Air Conditioner

Necessary Tools for Installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
Accessory parts
No.
Accessory parts
1
Remote controller
2
R-03 dry battery
3
Mounting plate
4
Drain hose
4X50
5
Steel nail, cement
6
4X25
Plastic cap
Screw
7
Cover
8
Cushion
9
Pipe supporting plate
10
Drain-elbow
No.0010518785
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
Drawing for the installation of indoor and outdoor units
Number
of
articles
1
Optional parts for piping
Mark
Parts name
2
A
Non-adhesive tape
Adhesive tape
B
1
C
Saddle(L.S) with screws
Connecting electric cable
D
for indoor and outdoor
1
Drain hose
E
F
Heating insulating material
6
Piping hole cover
G
4
1
Arrangement of piping directions
4
Rear left
Left
1
Below
1
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
9.Nipper
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Rear
right
Right
The marks from
A
to
G
in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
12.Reamer
Attention must be paid to
the rising up of drain hose
A
C
E
D

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU-24LEA03-T - annexe 1

  • Page 1: Installation Manual Of Room Air Conditioner

    Arrangement of piping directions Cushion Rear left Rear Left right Pipe supporting plate Right Below Drain-elbow The marks from in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. No.0010518785...
  • Page 2: Selection Of Installation Place

    Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate. Install an exclusive branch circuit of the power. A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it. Selection of pipe...
  • Page 4: Fixing The Indoor Unit Body

    Indoor unit 1. Insert the drain hose into the dent of heat insulation materials of indoor unit. 2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. 3. Coat the flaring seal face with refrigerant oil and connect pipes.
  • Page 5: Connecting The Indoor/Outdoor Electric Cable

    1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
  • Page 7: Outdoor Unit

    80g more refrigerant than regulated weight. Only for first installation, this extra 80g can be used to purge air in pipes. During this procedure, 80g refrigerant will be discharged piping.

Table of Contents