Operation
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Remote controller's operation
When in use, put the signal transmission head directly to the
receiver hole on the indoor unit.
The distance between the signal transmission head and the
HSU-09H03/R2(DB)
receiver hole should be within 7m without any obstacle as well.
HSU-12H03/R2(DB)
HSU-12HB03/R2(DB)
HSU-18H03/R2(DB)
HSU-12HD03/R2(DB)
Don't throw the controller, prevent it from being damaged.
When electronic-started type fluorescent lamp or change-over
type fluorescent lamp or wireless telephone is installed in the
room, the receiver is apt to be disturbed in receivering the signals
Fixing of outdoor unit
so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder)
Indoor Unit
Remove the battery cover:
Slightly press "
" and push down the cover.
Place, robust not causing vibration, where the body can be supported
sufficiently.
Place, not affected by heat or steam generated in the vicinity, where
Load the battery:
inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the
Be sure that the loading is in line with the" + "/"-"
outdoor unit.
pole request as illustrated.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer
Put on the cover again
to drawings).
Place where the distance of more than lm from televisions, radios,
Confirmation indicator:
wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the
In disorderation, reload the batteries or load the new batteries after 6mins.
indoor unit can receive signals when the fluorescent lamps in the room
are lightened.
Note:
Use two new same-typed batteries when loading.
If the remote controller can't run normally or doesn't work at all,
use a sharp pointed item to press the reset key.
Hint:
Remove the batteries in case unit won't be in usage for a long period.
If there are any display after taking-out just need to press reset key.
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name p
Power failure resume(please set and apply as necessary)
Install an exclusive branch circuit of the power.
If sudden power failure occurs, the unit will resume original operation when power is
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
supplied again.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if
the air conditioner is not desired for use in a long period, please shut off the power supply
in case that the unit automatically resume operation when power is re-supplied, or press
ON/OFF to turn off the unit when power resumes.
To this unit, both liquid and gas pipes shall be insulated
as they become low temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
The thickness of the pipe must be 0.8mm at least.
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizonta
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with na
or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.
Selection of Installation Place
Power Source
Selection of pipe
5
113.5
583
113.5
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-22H03/R2(DB)
Place, which is less affected by rain or direct sunlight an
sufficiently ventilated.
ÇëÑ¡ÓÃͬһƷÅÆÁ½½Ú
7#
µç³Ø,³¤Ê±¼ä²»ÓÃʱ,Ϊ
·Àֹ©ҹÇ뽫µç³ØÈ¡
ÔÚʹÓÃÖÐÈçÓöÒì³£,Çë
³ö¡£
½«µç³ØÈ¡³ö,6·ÖÖÓºóÔÙ
×°Èëеç³Ø¡£
º£¶û¼¯ÍÅÇൺº£¶û
¿Õµ÷Æ÷ÓÐÏÞ×ܹ«Ë¾
Place, possible to bear the unit, where vibration and nois
not increased.
Place, where discharged wind and noise do not cause a
nuisance to the neighbors.
Place, where a distance marked
in the above figure.
HSU-09H03/R2(DB)
HSU-12HB03/R2(DB)
HSU-12HD03/R2(DB)
Liquid pipe
6.35mm(1/4")
Gas pipe
9.52mm(3/8")
Outdoor Unit
ÇëÑ¡ÓÃͬһƷÅÆÁ½½Ú
7#
µç³Ø,³¤Ê±¼ä²»ÓÃʱ,Ϊ
·Àֹ©ҹÇ뽫µç³ØÈ¡
³ö¡£
ÔÚʹÓÃÖÐÈçÓöÒì³£,Çë
½«µç³ØÈ¡³ö,6·ÖÖÓºóÔÙ
×°Èëеç³Ø¡£
º£¶û¼¯ÍÅÇൺº£¶û
¿Õµ÷Æ÷ÓÐÏÞ×ܹ«Ë¾
is available as illustr
HSU-12H03/R2(DB)
HSU-18H03/R2(DB)
HSU-22H03/R2(DB)
6.35mm(1/4")
12.7mm(1/2")